Interval Partial Least-Squares Regression (i PLS): A Comparative Chemometric Study with an Example from Near-Infrared Spectroscopy
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
A new graphically oriented local modeling procedure called interval partial least-squares ( iPLS) is presented for use on spectral data. The iPLS method is compared to full-spectrum partial least-squares and the variable selection methods principal variables (PV), forward stepwise selection (FSS), and recursively weighted regression (RWR). The methods are tested on a near-infrared (NIR) spectral data set recorded on 60 beer samples correlated to original extract concentration. The error of the full-spectrum correlation model between NIR and original extract concentration was reduced by a factor of 4 with the use of iPLS ( r = 0.998, and root mean square error of prediction equal to 0.17% plato), and the graphic output contributed to the interpretation of the chemical system under observation. The other methods tested gave a comparable reduction in the prediction error but suffered from the interpretation advantage of the graphic interface. The intervals chosen by iPLS cover both the variables found by FSS and all possible combinations as well as the variables found by PV and RWR, and iPLS is still able to utilize the first-order advantage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Holland, J. H. (1992) · The MIT Press eBooks · doi:10.7551/mitpress/1090.001.0001 · Cited by 47,002
Near-Infrared Technology: In the Agricultural and Food Industries
Williams, P. C., & Norris, K. (2001) · Andalas University Repository (Andalas University) · Cited by 2,749
Cross-Validatory Estimation of the Number of Components in Factor and Principal Components Models
Wold, S. (1978) · Technometrics · doi:10.1080/00401706.1978.10489693 · Cited by 2,601
Selection of Variables to Preserve Multivariate Data Structure, Using Principal Components
Krzanowski, W. J. (1987) · Applied Statistics · doi:10.2307/2347842 · Cited by 275
Theoretical Justification of Wavelength Selection in PLS Calibration: Development of a New Algorithm
Spiegelman, C. H., McShane, M. J., Goetz, M. J., Motamedi, M., Yue, Q. L., & Coté, G. L. (1998) · Analytical Chemistry · doi:10.1021/ac9705733 · Cited by 261
McCabe, G. P. (1984) · Technometrics · doi:10.1080/00401706.1984.10487939 · Cited by 211
Munck, L., Nørgaard, L., Engelsen, S. B., Bro, R., & Andersson, C. A. (1998) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(98)00074-4 · Cited by 166
Self-citationBrown, P. J. (1994) · doi:10.1093/oso/9780198522454.003.0005 · Cited by 126
Explorative spectrometric evaluations of frying oil deterioration
Engelsen, S. B. (1997) · Journal of the American Oil Chemists Society · doi:10.1007/s11746-997-0068-2 · Cited by 86
Self-citation
Cited by
A review of variable selection methods in Partial Least Squares Regression
Mehmood, T., Liland, K. H., Snipen, L., & Sæbø, S. (2012) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2012.07.010 · Cited by 1,591
Near infrared spectroscopy: A mature analytical technique with new perspectives – A review
Pasquini, C. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.04.004 · Cited by 1,153
Variables selection methods in near-infrared spectroscopy
Xiaobo, Z., Jiewen, Z., Povey, M. J. W., Holmes, M., & Hanpin, M. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.03.048 · Cited by 1,080
icoshift: A versatile tool for the rapid alignment of 1D NMR spectra
Savorani, F., Tomasi, G., & Engelsen, S. B. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2009.11.012 · Cited by 850
Self-citationMultivariate data analysis in pharmaceutics: A tutorial review
Rajalahti, T., & Kvalheim, O. M. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2011.02.019 · Cited by 768
Variable selection in regression—a tutorial
Andersen, C. M., & Bro, R. (2010) · Journal of Chemometrics · doi:10.1002/cem.1360 · Cited by 697
Cai, W., Li, Y., & Shao, X. (2008) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2007.10.001 · Cited by 573
An overview of variable selection methods in multivariate analysis of near-infrared spectra
Yun, Y.-H., Li, H.-D., Deng, B.-C., & Cao, D.-S. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.01.018 · Cited by 564
NIR Spectroscopy Applications for Internal and External Quality Analysis of Citrus Fruit—A Review
Magwaza, L. S., Opara, U. L., Nieuwoudt, H., Cronje, P. J. R., Saeys, W., & Nicolaï, B. (2012) · Food and Bioprocess Technology · doi:10.1007/s11947-011-0697-1 · Cited by 465
Quantitative Analysis Using Raman Spectrometry
Pelletier, M. J. (2003) · Applied Spectroscopy · doi:10.1366/000370203321165133 · Cited by 435
(2013) · CRC Press eBooks · doi:10.1201/b15314 · Cited by 435
Berger, K., Verrelst, J., Féret, J.-B., Wang, Z., Wocher, M., Strathmann, M., Danner, M., Mauser, W., & Hank, T. (2020) · Remote Sensing of Environment · doi:10.1016/j.rse.2020.111758 · Cited by 429
Balabin, R. M., & Smirnov, S. V. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.03.006 · Cited by 398
Smolinska, A., Blanchet, L., Buydens, L. M. C., & Wijmenga, S. S. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.05.049 · Cited by 397
Shi, T., Chen, Y., Liu, Y., & Wu, G. (2014) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2013.11.059 · Cited by 377
Tutorial: multivariate classification for vibrational spectroscopy in biological samples
Morais, C. L. M., Lima, K. M. G., Singh, M., & Martin, F. L. (2020) · Nature Protocols · doi:10.1038/s41596-020-0322-8 · Cited by 355
mdatools – R package for chemometrics
Kucheryavskiy, S. (2020) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2020.103937 · Cited by 332
Serbin, S. P., Dillaway, D. N., Kruger, E. L., & Townsend, P. A. (2012) · Journal of Experimental Botany · doi:10.1093/jxb/err294 · Cited by 313
Vohland, M., Ludwig, M., Thiele-Bruhn, S., & Ludwig, B. (2014) · Geoderma · doi:10.1016/j.geoderma.2014.01.013 · Cited by 289
Near-Infrared Spectroscopy—Its Versatility in Analytical Chemistry
Ozaki, Y. (2012) · Analytical Sciences · doi:10.2116/analsci.28.545 · Cited by 283
Variable and subset selection in PLS regression
Höskuldsson, A. (2001) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(00)00113-1 · Cited by 281
Lu, Y., Saeys, W., Kim, M., Peng, Y., & Lu, R. (2020) · Postharvest Biology and Technology · doi:10.1016/j.postharvbio.2020.111318 · Cited by 263
Westad, F., & Martens, H. (2000) · Journal of Near Infrared Spectroscopy · doi:10.1255/jnirs.271 · Cited by 248
Rajalahti, T., Arneberg, R., Kroksveen, A. C., Berle, M., Myhr, K.-M., & Kvalheim, O. M. (2009) · Analytical Chemistry · doi:10.1021/ac802514y · Cited by 225
Using variable combination population analysis for variable selection in multivariate calibration
Yun, Y.-H., Wang, W.-T., Deng, B.-C., Lai, G.-B., Liu, X.-B., Ren, D.-B., Liang, Y.-Z., Fan, W., & Xu, Q.-S. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.12.048 · Cited by 215
Tran, T. N., Afanador, N. L., Buydens, L. M. C., & Blanchet, L. (2014) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2014.08.005 · Cited by 211
Ma, Y., He, H., Wu, J., Wang, C., Chao, K., & Huang, Q. (2018) · Scientific Reports · doi:10.1038/s41598-017-18422-7 · Cited by 209
Jacquemoud, S., & Ustin, S. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108686457 · Cited by 204
Preprocessing methods for near‐infrared spectrum calibration
Jiao, Y., Li, Z., Chen, X., & Fei, S. (2020) · Journal of Chemometrics · doi:10.1002/cem.3306 · Cited by 198
A Bootstrap-VIP approach for selecting wavelength intervals in spectral imaging applications
Gosselin, R., Rodrigue, D., & Duchesne, C. (2010) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2009.09.005 · Cited by 197
Kano, M., & Fujiwara, K. (2013) · JOURNAL OF CHEMICAL ENGINEERING OF JAPAN · doi:10.1252/jcej.12we167 · Cited by 197
“Such preprocessing is commonly used in spectrum analysis (Norgaard et al., 2000). e parameters were selected through cross validation. e estimation results are summarized in Table 7. e estimation performance of Lasso was worse than PLS-All.”
MethodOptimization of rice amylose determination by NIR-spectroscopy using PLS chemometrics algorithms
Sampaio, P. S., Soares, A., Castanho, A., Almeida, A. S., Oliveira, J., & Brites, C. (2018) · Food Chemistry · doi:10.1016/j.foodchem.2017.09.058 · Cited by 197
Cervera, A. E., Petersen, N., Lantz, A. E., Larsen, A., & Gernaey, K. V. (2009) · Biotechnology Progress · doi:10.1002/btpr.280 · Cited by 175
“As the developers of iPLS state, the main contribution from using iPLS is the graphic output giving an overview of the spectral data.(58) GAs(57) are optimization methods based on the principles of genetics and natural selection.”
MethodLi, X., Wei, Y., Xu, J., Xu, N., & He, Y. (2018) · Biotechnology for Biofuels · doi:10.1186/s13068-018-1251-4 · Cited by 173
“The iPLS aims to extract important spectral regions and eliminate interferences from other regions by establishing a set of local PLSR models on equidistant subintervals of the full-spectrum region [31].”
BackgroundXiong, Z., Sun, D.-W., Zeng, X.-A., & Xie, A. (2014) · Journal of Food Engineering · doi:10.1016/j.jfoodeng.2014.02.004 · Cited by 166
Quantitative Analysis of Red Wine Tannins Using Fourier-Transform Mid-Infrared Spectrometry
Fernández, K., & Agosin, E. (2007) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf071193d · Cited by 163
Giraudo, A., Grassi, S., Savorani, F., Gavoci, G., Casiraghi, E., & Geobaldo, F. (2019) · Food Control · doi:10.1016/j.foodcont.2018.12.033 · Cited by 162
Yun, Y.-H., Bin, J., Liu, D.-L., Xu, L., Yan, T.-L., Cao, D.-S., & Xu, Q.-S. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.01.022 · Cited by 160
Rasmussen, L. G., Winning, H., Savorani, F., Toft, H., Larsen, T. M., Dragsted, L. O., Astrup, A., & Engelsen, S. B. (2012) · Nutrients · doi:10.3390/nu4020112 · Cited by 81
Feidl, F., Garbellini, S., Vogg, S., Sokolov, M., Souquet, J., Broly, H., Butté, A., & Morbidelli, M. (2019) · Biotechnology Progress · doi:10.1002/btpr.2847 · Cited by 59
“Wavelength selection based on either variable importance on projection (VIP)(24) or interval Partial least squares (PLS).(25) 6.”
MethodMancini, M., Rinnan, Å., Pizzi, A., Mengarelli, C., Rossini, G., Duca, D., & Toscano, G. (2018) · Fuel · doi:10.1016/j.fuel.2018.01.008 · Cited by 33
Metadata
- Authors
- Nørgaard, L., Saudland, A., Wagner, J., Nielsen, J. P., Munck, L., & Engelsen, S. B.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2000-03
- Volume
- 54
- Issue
- 3
- Pages
- 413-419
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2007808016
- Cited by
- 1,361
- References
- 9
- FWCI
- 12.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.