The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Raman Spectra of Biological Samples: A Study of Preprocessing Methods
Abstract
In this study preprocessing of Raman spectra of different biological samples has been studied, and their effect on the ability to extract robust and quantitative information has been evaluated. Four data sets of Raman spectra were chosen in order to cover different aspects of biological Raman spectra, and the samples constituted salmon oils, juice samples, salmon meat, and mixtures of fat, protein, and water. A range of frequently used preprocessing methods, as well as combinations of different methods, was evaluated. Different aspects of regression results obtained from partial least squares regression (PLSR) were used as indicators for comparing the effect of different preprocessing methods. The results, as expected, suggest that baseline correction methods should be performed in advance of normalization methods. By performing total intensity normalization after adequate baseline correction, robust calibration models were obtained for all data sets. Combination methods like standard normal variate (SNV), multiplicative signal correction (MSC), and extended multiplicative signal correction (EMSC) in their basic form were not able to handle the baseline features present in several of the data sets, and these methods thus provide no additional benefits compared to the approach of baseline correction in advance of total intensity normalization. EMSC provides additional possibilities that require further investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Martens, H., & Stark, E. (1991) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/0731-7085(91)80188-f · Cited by 515
Cited by
Bro, R., & Smilde, A. K. (2014) · Anal. Methods · doi:10.1039/c3ay41907j · Cited by 3,038
Spectral pre-processing for biomedical vibrational spectroscopy and microspectroscopic imaging
Lasch, P. (2012) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2012.03.011 · Cited by 353
Cell death stages in single apoptotic and necrotic cells monitored by Raman microspectroscopy
Brauchle, E., Thude, S., Brucker, S. Y., & Schenke-Layland, K. (2014) · Scientific Reports · doi:10.1038/srep04698 · Cited by 310
Spectral pre and post processing for infrared and Raman spectroscopy of biological tissues and cells
Byrne, H. J., Knief, P., Keating, M. E., & Bonnier, F. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00440c · Cited by 213
Berry, B., Moretto, J., Matthews, T., Smelko, J., & Wiltberger, K. (2015) · Biotechnology Progress · doi:10.1002/btpr.2035 · Cited by 142
Metadata
- Authors
- Afseth, N. K., Segtnan, V. H., & Wold, J. P.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2006-12
- Volume
- 60
- Issue
- 12
- Pages
- 1358-1367
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W1972288639
- Cited by
- 205
- References
- 2
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Raman Spectra of Biological Samples: A Study of Preprocessing Methods. https://app.cochat.ai/papers/10.1366/000370206779321454
- The paper
- Afseth, N. K., Segtnan, V. H., & Wold, J. P. (2006). Raman Spectra of Biological Samples: A Study of Preprocessing Methods. Applied Spectroscopy. https://doi.org/10.1366/000370206779321454
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.