The Effect of Multiplicative Scatter Correction (MSC) and Linearity Improvement in NIR Spectroscopy
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Near-infrared (NIR) reflectance spectra of five different food products were measured. The spectra were transformed by multiplicative scatter correction (MSC). Principal component regression (PCR) was performed, on both scatter-corrected and uncorrected spectra. Calibration and prediction were performed for four food constituents: protein, fat, water, and carbohydrates. All regressions gave lower prediction errors (7–68% improvement) by the use of MSC spectra than by the use of uncorrected absorbance spectra. One of these data sets was studied in more detail to clarify the effects of the MSC, by using PCR score, residual, and leverage plots. The improvement by using nonlinear regression methods is indicated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cross validatory choice and assessment of statistical predictions
Stone, M. (1974) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1974.tb00994.x · Cited by 10,881
Estimating Optimal Transformations for Multiple Regression and Correlation
Breiman, L., & Friedman, J. H. (1985) · Journal of the American Statistical Association · doi:10.1080/01621459.1985.10478157 · Cited by 1,710
Linearization and Scatter-Correction for Near-Infrared Reflectance Spectra of Meat
Geladi, P., MacDougall, D., & Martens, H. (1985) · Applied Spectroscopy · doi:10.1366/0003702854248656 · Cited by 1,513
A Note on the Use of Principal Components in Regression
Jolliffe, I. T. (1982) · Applied Statistics · doi:10.2307/2348005 · Cited by 829
Use of the Singular Value Decomposition in Regression Analysis
Mandel, J. (1982) · The American Statistician · doi:10.1080/00031305.1982.10482771 · Cited by 281
Næs, T., & Martens, H. (1988) · Journal of Chemometrics · doi:10.1002/cem.1180020207 · Cited by 230
Self-citationNear-Infrared Analysis (NIRA): A Technology for Quantitative and Qualitative Analysis
Stark, E., Luchter, K., & Margoshes, M. (1986) · Applied Spectroscopy Reviews · doi:10.1080/05704928608060440 · Cited by 203
Comparison of Linear Statistical Methods for Calibration of NIR Instruments
Næs, T., Irgens, C., & Martens, H. A. (1986) · Journal of the Royal Statistical Society Series C (Applied Statistics) · doi:10.2307/2347270 · Cited by 79
Self-citation(1931) · Medical Entomology and Zoology
Cited by
Nondestructive measurement of fruit and vegetable quality by means of NIR spectroscopy: A review
Nicolaï, B. M., Beullens, K., Bobelyn, E., Peirs, A., Saeys, W., Theron, K. I., & Lammertyn, J. (2007) · Postharvest Biology and Technology · doi:10.1016/j.postharvbio.2007.06.024 · Cited by 2,252
Theory and application of near infrared reflectance spectroscopy in determination of food quality
Cen, H., & He, Y. (2007) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2006.09.003 · Cited by 1,030
Elimination of Uninformative Variables for Multivariate Calibration
Centner, V., Massart, D.-L., de Noord, O. E., de Jong, S., Vandeginste, B. M., & Sterna, C. (1996) · Analytical Chemistry · doi:10.1021/ac960321m · Cited by 998
Transfer of multivariate calibration models: a review
Feudale, R. N., Woody, N. A., Tan, H., Myles, A. J., Brown, S. D., & Ferré, J. (2002) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(02)00085-0 · Cited by 555
Hierlemann, A., & Gutierrez-Osuna, R. (2008) · Chemical Reviews · doi:10.1021/cr068116m · Cited by 456
Gemperline, P. J., Long, J. R., & Gregoriou, V. G. (1991) · Analytical Chemistry · doi:10.1021/ac00020a022 · Cited by 326
Ram, B. G., Oduor, P., Igathinathane, C., Howatt, K., & Sun, X. (2024) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2024.109037 · Cited by 315
Locally weighted regression and scatter correction for near-infrared reflectance data
Naes, T., Isaksson, T., & Kowalski, B. (1990) · Analytical Chemistry · doi:10.1021/ac00206a003 · Cited by 314
Self-citationHelland, I. (1995) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(95)00031-1 · Cited by 296
Barbin, D. F., Felicio, A. L. D. S. M., Sun, D.-W., Nixdorf, S. L., & Hirooka, E. Y. (2014) · Food Research International · doi:10.1016/j.foodres.2014.01.005 · Cited by 272
Lu, Y., Saeys, W., Kim, M., Peng, Y., & Lu, R. (2020) · Postharvest Biology and Technology · doi:10.1016/j.postharvbio.2020.111318 · Cited by 263
Predicting quality and sensory attributes of pork using near-infrared hyperspectral imaging
Barbin, D. F., ElMasry, G., Sun, D.-W., & Allen, P. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.01.004 · Cited by 251
Near-infrared spectroscopy in the pharmaceutical industry
Blanco, M., Coello, J., Iturriaga, H., Maspoch, S., & de la Pezuela, C. (1998) · The Analyst · doi:10.1039/a802531b · Cited by 239
The influence of data pre-processing in the pattern recognition of excipients near-infrared spectra
Candolfi, A., De Maesschalck, R., Jouan-Rimbaud, D., Hailey, P. A., & Massart, D. L. (1999) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/s0731-7085(99)00125-9 · Cited by 234
The parsimony principle applied to multivariate calibration
Seasholtz, M. B., & Kowalski, B. (1993) · Analytica Chimica Acta · doi:10.1016/0003-2670(93)80430-s · Cited by 233
Multivariate data analysis applied to spectroscopy: Potential application to juice and fruit quality
Cozzolino, D., Cynkar, W. U., Shah, N., & Smith, P. (2011) · Food Research International · doi:10.1016/j.foodres.2011.01.041 · Cited by 227
Preprocessing methods for near‐infrared spectrum calibration
Jiao, Y., Li, Z., Chen, X., & Fei, S. (2020) · Journal of Chemometrics · doi:10.1002/cem.3306 · Cited by 198
“Multiplicative scatter correction (MSC) is widely applied in reflectance spectroscopy11–13 to eliminate the absorbance displacement and slope shift due to the scattering of light.(14) Orthogonal signal correction (OSC)(15) and the net analyte signal (NAS)(16) approaches can produce a simpler PLSR model that has fewer…”
BackgroundStandardisation of near-infrared spectrometric instruments: A review
Bouveresse, E., & Massart, D. L. (1996) · Vibrational Spectroscopy · doi:10.1016/0924-2031(95)00055-0 · Cited by 183
Wavelet Denoising of Infrared Spectra
Alsberg, B. K., Woodward, A. M., Winson, M. K., Rowland, J., & Kell, D. B. (1997) · The Analyst · doi:10.1039/a608255f · Cited by 172
O'Rourke, S. M., Stockmann, U., Holden, N. M., McBratney, A. B., & Minasny, B. (2016) · Geoderma · doi:10.1016/j.geoderma.2016.05.005 · Cited by 171
Bokobza, L. (1998) · Journal of Near Infrared Spectroscopy · doi:10.1255/jnirs.116 · Cited by 170
Near-infrared spectroscopy and imaging in food quality and safety
Wang, W., & Paliwal, J. (2007) · Sensing and Instrumentation for Food Quality and Safety · doi:10.1007/s11694-007-9022-0 · Cited by 169
Zeaiter, M., Roger, J.-M., & Bellon-Maurel, V. (2005) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2004.11.023 · Cited by 163
Marquetti, I., Link, J. V., Lemes, A. L. G., Scholz, M. B. D. S., Valderrama, P., & Bona, E. (2016) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2015.12.018 · Cited by 117
“It uses a linear regression of spectral variables versus the average spectrum (Isaksson and Næs, 1988).”
MethodReview of Chemometrics Applied to Spectroscopy: 1985-95, Part I
Workman, J. J., Mobley, P. R., Kowalski, B. R., & Bro, R. (1996) · Applied Spectroscopy Reviews · doi:10.1080/05704929608000565 · Cited by 117
The Christiansen effect in terahertz time-domain spectra of coarse-grained powders
Franz, M., Fischer, B. M., & Walther, M. (2008) · Applied Physics Letters · doi:10.1063/1.2831910 · Cited by 82
Metadata
- Authors
- Isaksson, T., & Næs, T.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 1988-09
- Volume
- 42
- Issue
- 7
- Pages
- 1273-1284
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2037275106
- Cited by
- 600
- References
- 9
- FWCI
- 7.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.