The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Fluorescence Rejection in Raman Spectroscopy by Shifted-Spectra, Edge Detection, and FFT Filtering Techniques
Abstract
The use of shifted-spectra, first-derivative spectroscopy (or edge detection), and fast Fourier transform filtering techniques for fluorescence rejection in Raman spectra is demonstrated. These techniques take advantage of the fact that Raman signals are very narrow in comparison to fluorescence bands in order to discriminate between the two. None of these techniques require modification of existing instrumentation. Fast Fourier transform filtering and deconvolution techniques also provide a means of improving spectral resolution and the signal-to-noise ratio.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Cited by
Automated Method for Subtraction of Fluorescence from Biological Raman Spectra
Lieber, C. A., & Mahadevan-Jansen, A. (2003) · Applied Spectroscopy · doi:10.1366/000370203322554518 · Cited by 1,049
Review of multidimensional data processing approaches for Raman and infrared spectroscopy
Gautam, R., Vanga, S., Ariese, F., & Umapathy, S. (2015) · EPJ Techniques and Instrumentation · doi:10.1140/epjti/s40485-015-0018-6 · Cited by 696
Spectral pre-processing for biomedical vibrational spectroscopy and microspectroscopic imaging
Lasch, P. (2012) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2012.03.011 · Cited by 353
Metadata
- Authors
- Mosier-Boss, P. A., Lieberman, S. H., & Newbery, R.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 1995-05
- Volume
- 49
- Issue
- 5
- Pages
- 630-638
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2077134794
- Cited by
- 221
- References
- 2
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescence Rejection in Raman Spectroscopy by Shifted-Spectra, Edge Detection, and FFT Filtering Techniques. https://app.cochat.ai/papers/10.1366/0003702953964039
- The paper
- Mosier-Boss, P. A., Lieberman, S. H., & Newbery, R. (1995). Fluorescence Rejection in Raman Spectroscopy by Shifted-Spectra, Edge Detection, and FFT Filtering Techniques. Applied Spectroscopy. https://doi.org/10.1366/0003702953964039
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.