Fluorescence Rejection in Raman Spectroscopy by Shifted-Spectra, Edge Detection, and FFT Filtering Techniques
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The use of shifted-spectra, first-derivative spectroscopy (or edge detection), and fast Fourier transform filtering techniques for fluorescence rejection in Raman spectra is demonstrated. These techniques take advantage of the fact that Raman signals are very narrow in comparison to fluorescence bands in order to discriminate between the two. None of these techniques require modification of existing instrumentation. Fast Fourier transform filtering and deconvolution techniques also provide a means of improving spectral resolution and the signal-to-noise ratio.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Fourier Self-Deconvolution: A Method for Resolving Intrinsically Overlapped Bands
Kauppinen, J. K., Moffatt, D. J., Mantsch, H. H., & Cameron, D. G. (1981) · Applied Spectroscopy · doi:10.1366/0003702814732634 · Cited by 1,301
Kasha, M. (1952) · The Journal of Chemical Physics · doi:10.1063/1.1700199 · Cited by 460
Shreve, A. P., Cherepy, N. J., & Mathies, R. A. (1992) · Applied Spectroscopy · doi:10.1366/0003702924125122 · Cited by 312
UV Resonance Raman Spectroscopy for Analytical, Physical, and Biophysical Chemistry
Asher, S. A. (1993) · Analytical Chemistry · doi:10.1021/ac00050a717 · Cited by 198
Duyne, R. P. V., Jeanmaire, D. L., & Shriver, D. F. (1974) · Analytical Chemistry · doi:10.1021/ac60338a012 · Cited by 141
(1971) · Nature · doi:10.1038/231424b0 · Cited by 108
Fluorescence rejection in Raman spectroscopy by a gated single-photon counting method
Watanabe, J., Kinoshita, S., & Kushida, T. (1985) · Review of Scientific Instruments · doi:10.1063/1.1138028 · Cited by 29
(1981)
Cited by
QUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSIS
Richards-Kortum, R., & Sevick-Muraca, E. (1996) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.47.1.555 · Cited by 1,172
Automated Method for Subtraction of Fluorescence from Biological Raman Spectra
Lieber, C. A., & Mahadevan-Jansen, A. (2003) · Applied Spectroscopy · doi:10.1366/000370203322554518 · Cited by 1,049
Automated Autofluorescence Background Subtraction Algorithm for Biomedical Raman Spectroscopy
Zhao, J., Lui, H., McLean, D. I., & Zeng, H. (2007) · Applied Spectroscopy · doi:10.1366/000370207782597003 · Cited by 810
Review of multidimensional data processing approaches for Raman and infrared spectroscopy
Gautam, R., Vanga, S., Ariese, F., & Umapathy, S. (2015) · EPJ Techniques and Instrumentation · doi:10.1140/epjti/s40485-015-0018-6 · Cited by 696
“The baseline corrected Raman signal can be reconstructed by applying Inverse Fourier Transform (IFT) on these modified amplitudes [25, 30].”
MethodRaman spectroscopy for the detection of cancers and precancers
Mahadevan-Jansen, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.227815 · Cited by 475
Metadata
- Authors
- Mosier-Boss, P. A., Lieberman, S. H., & Newbery, R.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 1995-05
- Volume
- 49
- Issue
- 5
- Pages
- 630-638
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2077134794
- Cited by
- 221
- References
- 10
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.