The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
New Procedure for Quantitative Elemental Analysis by Laser-Induced Plasma Spectroscopy
Abstract
A new procedure, based on the laser-induced plasma spectroscopy (LIPS) technique, is proposed for calibration-free quantitative elemental analysis of materials. The method here presented, based on an algorithm developed and patented by IFAM-CNR, allows the matrix effects to be overcome, yielding precise and accurate quantitative results on elemental composition of materials without use of calibration curves. Some applications of the method are illustrated, for quantitative analysis of the composition of metallic alloys and quantitative determination of the composition of the atmosphere.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matrix Effects in the Detection of Pb and Ba in Soils Using Laser-Induced Breakdown Spectroscopy
Eppler, A. S., Cremers, D. A., Hickmott, D. D., Ferris, M. J., & Koskelo, A. C. (1996) · Applied Spectroscopy · doi:10.1366/0003702963905123 · Cited by 298
CHALÉARD, C., MAUCHIEN, P., ANDRE, N., UEBBING, J., L. LACOUR, J., & GEERTSEN, C. (1997) · J. Anal. At. Spectrom. · doi:10.1039/a604456e · Cited by 190
The Analysis of Metals at a Distance Using Laser-Induced Breakdown Spectroscopy
Cremers, D. A. (1987) · Applied Spectroscopy · doi:10.1366/0003702874448742 · Cited by 184
Absolute Analysis of Particulate Materials by Laser-Induced Breakdown Spectroscopy
Xu, L., Bulatov, V., Gridin, V. V., & Schechter, I. (1997) · Analytical Chemistry · doi:10.1021/ac970006f · Cited by 128
Determination of Sulfur Content in Steel by Laser-Produced Plasma Atomic Emission Spectroscopy
Gonzcález, A., Ortiz, M. C. R., & Campos, J. (1995) · Applied Spectroscopy · doi:10.1366/0003702953965768 · Cited by 71
Cited by
Hahn, D. W., & Omenetto, N. (2012) · Applied Spectroscopy · doi:10.1366/11-06574 · Cited by 1,497
Cristoforetti, G., De Giacomo, A., Dell'Aglio, M., Legnaioli, S., Tognoni, E., Palleschi, V., & Omenetto, N. (2010) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2009.11.005 · Cited by 682
Self-citationAragón, C., & Aguilera, J. A. (2008) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2008.05.010 · Cited by 636
Winefordner, J. D., Gornushkin, I. B., Correll, T., Gibb, E., Smith, B. W., & Omenetto, N. (2004) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b400355c · Cited by 486
Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art
Tognoni, E., Cristoforetti, G., Legnaioli, S., & Palleschi, V. (2010) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2009.11.006 · Cited by 465
“The Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) approach [7] was developed following an alternative view; instead of looking at the matrix as an external disturbing interference, it takes the matrix into account as a part of the analytical problem: it analyzes the matrix together with the analyte.”
BackgroundMethodSelf-citation
Metadata
- Authors
- Ciucci, A., Corsi, M., Palleschi, V., Rastelli, S., Salvetti, A., & Tognoni, E.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 1999-08
- Volume
- 53
- Issue
- 8
- Pages
- 960-964
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2132355204
- Cited by
- 879
- References
- 5
- FWCI
- 22.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.