CoChat

Different Origins of Gamma Rhythm and High-Gamma Activity in Macaque Visual Cortex

Open access
Ray, Supratim, Maunsell, John H. R. · 2011 · PLoS Biology

The DOI matches its Crossref record; 63 of the 64 references it cites were found in a registry or an index.

Abstract

During cognitive tasks electrical activity in the brain shows changes in power in specific frequency ranges, such as the alpha (8-12 Hz) or gamma (30-80 Hz) bands, as well as in a broad range above ∼80 Hz, called the high-gamma band. The role or significance of this broadband high-gamma activity is unclear. One hypothesis states that high-gamma oscillations serve just like gamma oscillations, operating at a higher frequency and consequently at a faster timescale. Another hypothesis states that high-gamma power is related to spiking activity. Because gamma power and spiking activity tend to co-vary during most stimulus manipulations (such as contrast modulations) or cognitive tasks (such as attentional modulation), it is difficult to dissociate these two hypotheses. We studied the relationship between high-gamma power, gamma rhythm, and spiking activity in the primary visual cortex (V1) of awake monkeys while varying the stimulus size, which increased the gamma power but decreased the firing rate, permitting a dissociation. We found that gamma power became anti-correlated with the high-gamma power, suggesting that the two phenomena are distinct and have different origins. On the other hand, high-gamma power remained tightly correlated with spiking activity under a wide range of stimulus manipulations. We studied this relationship using a signal processing technique called Matching Pursuit and found that action potentials are associated with sharp transients in the LFP with broadband power, which is visible at frequencies as low as ∼50 Hz. These results distinguish broadband high-gamma activity from gamma rhythms as an easily obtained and reliable electrophysiological index of neuronal firing near the microelectrode. Further, they highlight the importance of making a careful dissociation between gamma rhythms and spike-related transients that could be incorrectly decomposed as rhythms using traditional signal processing methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pbio.1000610

Cites

63 of 63 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Dissociation of the gamma rhythm and high-gamma activity by manipulating stimulus size. (A) Average multiunit recorded from a single site in Monkey 1 during the presentation of a static grating (0 to 400 ms) at six different sizes, shown in different colors. The inset shows the average firing rate between 200 and 400 ms, indicated by a thick black line on the abscissa. (B) Time-frequency energy difference plots (in dB) showing the difference in energy from baseline energy (−300 to 0 ms, 0 denotes the stimulus onset, difference computed separately for each frequency) for the smallest (radius of 0.3°, left panel), medium (1.14°, middle), and largest (2.4°, right) sizes. The gamma rhythm at ∼50 Hz increases with size, while the high-gamma activity above the gamma band decreases with size. (C) The LFP energy between 200 and 400 ms (denoted by a thick black line on the abscissa in B) as a function of frequency for the six sizes, whose radii are listed in the legend. The black line shows the LFP energy in the baseline period. (D–F) and (G–I) show corresponding population responses of 15 and 104 sites from Monkeys 1 and 2, respectively. For (D) and (G), the responses are normalized by dividing by the maximum firing rate for each site. Monkey 2 showed two distinct gamma bands at ∼50 and ∼90 Hz.
Figure 1 Dissociation of the gamma rhythm and high-gamma activity by manipulating stimulus size. (A) Average multiunit recorded from a single site in Monkey 1 during the presentation of a static grating (0 to 400 ms) at six different sizes, shown in different colors. The inset shows the average firing rate between 200 and 400 ms, indicated by a thick black line on the abscissa. (B) Time-frequency energy difference plots (in dB) showing the difference in energy from baseline energy (−300 to 0 ms, 0 denotes the stimulus onset, difference computed separately for each frequency) for the smallest (radius of 0.3°, left panel), medium (1.14°, middle), and largest (2.4°, right) sizes. The gamma rhythm at ∼50 Hz increases with size, while the high-gamma activity above the gamma band decreases with size. (C) The LFP energy between 200 and 400 ms (denoted by a thick black line on the abscissa in B) as a function of frequency for the six sizes, whose radii are listed in the legend. The black line shows the LFP energy in the baseline period. (D–F) and (G–I) show corresponding population responses of 15 and 104 sites from Monkeys 1 and 2, respectively. For (D) and (G), the responses are normalized by dividing by the maximum firing rate for each site. Monkey 2 showed two distinct gamma bands at ∼50 and ∼90 Hz.CC BY · PubMed Central
Figure 2 Correlations between power and firing rates have different signs in gamma versus high-gamma bands. (A) Average relative change in power between 200 and 400 ms from baseline power (difference between the colored traces and the black trace in Figure 1F and 1I), for 15 and 104 sites in Monkeys 1 (left panel) and 2 (right panel). Radii are listed again in the legend for clarity. (B) Spearman rank correlation between the six power values (one for each size) at each frequency and the six firing rates values, computed individually for each site and then averaged. Black and gray traces show the mean and SEM of 15 and 104 sites in the two monkeys. The correlation values significantly different from zero are shown in green (p<0.01, uncorrected) and red (p<0.05 with Bonferroni correction).
Figure 2 Correlations between power and firing rates have different signs in gamma versus high-gamma bands. (A) Average relative change in power between 200 and 400 ms from baseline power (difference between the colored traces and the black trace in Figure 1F and 1I), for 15 and 104 sites in Monkeys 1 (left panel) and 2 (right panel). Radii are listed again in the legend for clarity. (B) Spearman rank correlation between the six power values (one for each size) at each frequency and the six firing rates values, computed individually for each site and then averaged. Black and gray traces show the mean and SEM of 15 and 104 sites in the two monkeys. The correlation values significantly different from zero are shown in green (p<0.01, uncorrected) and red (p<0.05 with Bonferroni correction).CC BY · PubMed Central
Figure 3 Changes in power with stimulus size are observed even when firing rates are negligible. (A) Average firing rate of 30 and 10 sites in Monkeys 1 (left column) and 2 (right column), for which less than 0.5 spikes/s were obtained between 200 and 400 ms. (B) Difference in power between 200 and 400 ms from baseline power (same format as Figure 2A) for these sites.
Figure 3 Changes in power with stimulus size are observed even when firing rates are negligible. (A) Average firing rate of 30 and 10 sites in Monkeys 1 (left column) and 2 (right column), for which less than 0.5 spikes/s were obtained between 200 and 400 ms. (B) Difference in power between 200 and 400 ms from baseline power (same format as Figure 2A) for these sites.CC BY · PubMed Central
Figure 4 Correlations between the time-courses of firing rate and LFP power in different frequency bands. (A) The mean time-frequency energy difference plot (in dB) of 15 sites from Monkey 1, when the largest stimulus is presented. Same as the right panel of Figure 1E, except that the displayed frequency range is up to 500 Hz. The vertical colored lines in the right mark the four frequency bands used for analysis—alpha (8–12 Hz; magenta), gamma (30–80 Hz; dark green), high-gamma (102–238 Hz, excluding 118–122 Hz; light green), and 250–500 Hz (brown). (B) Panels in the left column show the relative change in LFP power in the four frequency bands (colored traces) for the largest stimulus, along with the relative change in firing rate (black trace, same for all panels). The Spearman rank correlation between the two traces is denoted in the upper-left corner. Panels in the right show the relative change in LFP power for different stimulus size (same color code as Figures 1 and 2, the orange trace is the same as the colored trace in the left column). (C, D) Same as (A, B) for 104 sites in Monkey 2.
Figure 4 Correlations between the time-courses of firing rate and LFP power in different frequency bands. (A) The mean time-frequency energy difference plot (in dB) of 15 sites from Monkey 1, when the largest stimulus is presented. Same as the right panel of Figure 1E, except that the displayed frequency range is up to 500 Hz. The vertical colored lines in the right mark the four frequency bands used for analysis—alpha (8–12 Hz; magenta), gamma (30–80 Hz; dark green), high-gamma (102–238 Hz, excluding 118–122 Hz; light green), and 250–500 Hz (brown). (B) Panels in the left column show the relative change in LFP power in the four frequency bands (colored traces) for the largest stimulus, along with the relative change in firing rate (black trace, same for all panels). The Spearman rank correlation between the two traces is denoted in the upper-left corner. Panels in the right show the relative change in LFP power for different stimulus size (same color code as Figures 1 and 2, the orange trace is the same as the colored trace in the left column). (C, D) Same as (A, B) for 104 sites in Monkey 2.CC BY · PubMed Central
Figure 5 Correlations between firing rate and LFP power in different frequency bands for stimuli with different temporal frequency profiles. (A) The left panel shows the average time-frequency energy difference spectrum of 19 sites in Monkey 1 when the stimulus was presented with a counter-phasing temporal frequency of 2.5 Hz. The contrast profile is shown in red on top of the right panels. The right panels show the relative change in power in different frequency bands as well as in the firing rates, as a function of time. Same format as in Figure 4. The Spearman correlation values between the firing rate and power traces are shown in the top left corner. (B) Same as panel (A), for a temporal frequency of 5 Hz. (C, D) Same as (A, B) for 66 sites in Monkey 2.
Figure 5 Correlations between firing rate and LFP power in different frequency bands for stimuli with different temporal frequency profiles. (A) The left panel shows the average time-frequency energy difference spectrum of 19 sites in Monkey 1 when the stimulus was presented with a counter-phasing temporal frequency of 2.5 Hz. The contrast profile is shown in red on top of the right panels. The right panels show the relative change in power in different frequency bands as well as in the firing rates, as a function of time. Same format as in Figure 4. The Spearman correlation values between the firing rate and power traces are shown in the top left corner. (B) Same as panel (A), for a temporal frequency of 5 Hz. (C, D) Same as (A, B) for 66 sites in Monkey 2.CC BY · PubMed Central
Figure 6 Trial-by-trial Spearman correlation between firing rates and LFP power at different frequencies when stimulus conditions are identical. (A) The median Spearman rank correlation between LFP power at different frequency bins (size of 25 Hz, computed in steps of 10 Hz) and firing rates, both computed between 200 and 400 ms after stimulus onset, for 15 sites in Monkey 1. The correlations were computed separately for each size, site, and orientation, so that the stimulus conditions were identical. The first column shows the median correlations during the pre-stimulus period (denoted “BL” for baseline). The remaining six columns represent the six stimulus sizes (denoted by the respective color below the x-axis). (B) Median Spearman correlation, computed for the four frequency bands used in Figures 4 and 5. Correlations significantly different from zero (p<0.05, Bonferroni corrected) as shown with asterisks. (C,D) Same as (A, B) for 104 sites in Monkey 2.
Figure 6 Trial-by-trial Spearman correlation between firing rates and LFP power at different frequencies when stimulus conditions are identical. (A) The median Spearman rank correlation between LFP power at different frequency bins (size of 25 Hz, computed in steps of 10 Hz) and firing rates, both computed between 200 and 400 ms after stimulus onset, for 15 sites in Monkey 1. The correlations were computed separately for each size, site, and orientation, so that the stimulus conditions were identical. The first column shows the median correlations during the pre-stimulus period (denoted “BL” for baseline). The remaining six columns represent the six stimulus sizes (denoted by the respective color below the x-axis). (B) Median Spearman correlation, computed for the four frequency bands used in Figures 4 and 5. Correlations significantly different from zero (p<0.05, Bonferroni corrected) as shown with asterisks. (C,D) Same as (A, B) for 104 sites in Monkey 2.CC BY · PubMed Central
Figure 7 Spike-triggered average in time-frequency domain during baseline period. (A) The mean spike-triggered average from spikes taken between 268 and 132 ms before stimulus onset, from the 14 sites for which at least 25 spikes were obtained. (B) Left panel shows the spike-triggered time-frequency average (STTFA), computed by averaging short 2-D segments of the time-frequency energy spectrum centered on the spikes. The middle panel shows the STTFA computed after first randomizing the spike times (called rSTTFA). The panel in the right shows the relative change in the time-frequency spectrum locked to the spike, computed by taking the difference between log(STTFA) and log(rSTTFA) (called the normalized STTFA, or nSTTFA). (C) The mean energy between −1 to 3 ms of the STTFA (black) and the rSTTFA (gray), as a function of frequency (upper plot). The difference between the two is shown in the lower panel (mean in black, SEM in gray). The values significantly different from zero are shown in green (p<0.01, uncorrected) and red (p<0.05 with Bonferroni correction). (D–F) Same as (A–C), for 103 sites in Monkey 2.
Figure 7 Spike-triggered average in time-frequency domain during baseline period. (A) The mean spike-triggered average from spikes taken between 268 and 132 ms before stimulus onset, from the 14 sites for which at least 25 spikes were obtained. (B) Left panel shows the spike-triggered time-frequency average (STTFA), computed by averaging short 2-D segments of the time-frequency energy spectrum centered on the spikes. The middle panel shows the STTFA computed after first randomizing the spike times (called rSTTFA). The panel in the right shows the relative change in the time-frequency spectrum locked to the spike, computed by taking the difference between log(STTFA) and log(rSTTFA) (called the normalized STTFA, or nSTTFA). (C) The mean energy between −1 to 3 ms of the STTFA (black) and the rSTTFA (gray), as a function of frequency (upper plot). The difference between the two is shown in the lower panel (mean in black, SEM in gray). The values significantly different from zero are shown in green (p<0.01, uncorrected) and red (p<0.05 with Bonferroni correction). (D–F) Same as (A–C), for 103 sites in Monkey 2.CC BY · PubMed Central
Figure 8 Spike-triggered average in time-frequency domain during stimulus presentations. (A) Mean spike-triggered average of 15 sites for Monkey 1 for which at least 25 spikes were available between 232 and 368 ms after stimulus onset, for the six stimulus sizes. (B) The normalized STTFA (see text and Figure 7 for details) when a small (left), medium (middle), and large (right) stimulus was presented. (C) The difference between the mean energy between −1 and 3 ms of the STTFA and rSTTFA (same as the lower panel of Figure 7C), for the six stimulus sizes. The horizontal lines at the bottom indicate the “cutoff frequency” for each stimulus size (see text for definition). (D–F) Same as (A–C), for 94–103 sites in Monkey 2 for which at least 25 spikes could be obtained. The number of sites decreases from 103 to 94 because the firing rates decrease with increasing stimulus size.
Figure 8 Spike-triggered average in time-frequency domain during stimulus presentations. (A) Mean spike-triggered average of 15 sites for Monkey 1 for which at least 25 spikes were available between 232 and 368 ms after stimulus onset, for the six stimulus sizes. (B) The normalized STTFA (see text and Figure 7 for details) when a small (left), medium (middle), and large (right) stimulus was presented. (C) The difference between the mean energy between −1 and 3 ms of the STTFA and rSTTFA (same as the lower panel of Figure 7C), for the six stimulus sizes. The horizontal lines at the bottom indicate the “cutoff frequency” for each stimulus size (see text for definition). (D–F) Same as (A–C), for 94–103 sites in Monkey 2 for which at least 25 spikes could be obtained. The number of sites decreases from 103 to 94 because the firing rates decrease with increasing stimulus size.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 63 references

Cited by

Items 301–400 of 1,000

Metadata

Authors
Ray, S., & Maunsell, J. H. R.
Affiliations
Howard Hughes Medical Institute (US)
Corresponding author
Ray, Supratim
Venue
PLoS Biology
Published
2011-04-12
Volume
9
Issue
4
Pages
e1000610
ISSN
  • 1544-9173 (ISSN-L)
  • 1545-7885
OpenAlex
W1976211348
Cited by
1,012
References
64
Citations by year
2026: 56 · 2025: 72 · 2024: 84 · 2023: 81 · 2022: 77 · 2021: 79 · 2020: 65 · 2019: 57 · 2018: 67 · 2017: 61 · 2016: 75 · 2015: 60 · 2014: 77 · 2013: 58 · 2012: 29
FWCI
28.89
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • PLoS Biology (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Figshare (submittedVersion, cc-by)
Funders
  • Howard Hughes Medical Institute
  • National Institutes of Health
  • National Eye Institute (R01EY005911)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neuropharmacology Research
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Visual perception and processing mechanisms
Keywords
gamma oscillations, high gamma activity, primary visual cortex, macaque, spiking activity, local field potentials, stimulus size, firing rate, matching pursuit, neural oscillations, neuronal firing
MeSH terms
Animals, Behavior, Animal, Cognition, Electroencephalography, Macaca mulatta, Male, Neurons, Neuropsychological Tests, Periodicity, Reaction Time, Visual Cortex, Eye Movement Measurements, Brain Waves

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.