Improved genetically encoded near-infrared fluorescent calcium ion indicators for in vivo imaging
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Near-infrared (NIR) genetically encoded calcium ion (Ca 2+ ) indicators (GECIs) can provide advantages over visible wavelength fluorescent GECIs in terms of reduced phototoxicity, minimal spectral cross talk with visible light excitable optogenetic tools and fluorescent probes, and decreased scattering and absorption in mammalian tissues. Our previously reported NIR GECI, NIR-GECO1, has these advantages but also has several disadvantages including lower brightness and limited fluorescence response compared to state-of-the-art visible wavelength GECIs, when used for imaging of neuronal activity. Here, we report 2 improved NIR GECI variants, designated NIR-GECO2 and NIR-GECO2G, derived from NIR-GECO1. We characterized the performance of the new NIR GECIs in cultured cells, acute mouse brain slices, and Caenorhabditis elegans and Xenopus laevis in vivo. Our results demonstrate that NIR-GECO2 and NIR-GECO2G provide substantial improvements over NIR-GECO1 for imaging of neuronal Ca 2+ dynamics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Independent optical excitation of distinct neural populations
Klapoetke, N. C., Murata, Y., Kim, S. S., Pulver, S. R., Birdsey-Benson, A., Cho, Y. K., Morimoto, T. K., Chuong, A. S., Carpenter, E. J., Tian, Z., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2836 · Cited by 2,344 · cited 12×
“Optical stimulation of slices expressing NIR-GECO2 and CoChR was performed using a 470-nm LED (M470L3, ThorLabs, Newton, New Jersey, USA) at 0.157 mW/mm 2 .”
MethodInfluentialSelf-citation
Cited by
Structure- and mechanism-guided design of single fluorescent protein-based biosensors
Nasu, Y., Shen, Y., Kramer, L., & Campbell, R. E. (2021) · Nature Chemical Biology · doi:10.1038/s41589-020-00718-x · Cited by 225
Self-citationDong, C., Zheng, Y., Long-Iyer, K., Wright, E. C., Li, Y., & Tian, L. (2022) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-110520-031137 · Cited by 99
Fluorescent Protein-Based Sensors for Detecting Essential Metal Ions across the Tree of Life
Jensen, G. C., Janis, M. K., Nguyen, H. N., David, O. W., & Zastrow, M. L. (2024) · ACS Sensors · doi:10.1021/acssensors.3c02695 · Cited by 25
Genetically encoded fluorescent sensors for metals in biology
Torres-Ocampo, A. P., & Palmer, A. E. (2023) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2023.102284 · Cited by 22
Metadata
- Authors
- Qian, Y., Cosio, D. M. O., Piatkevich, K. D., Aufmkolk, S., Su, W.-C., Celiker, O. T., Schohl, A., Murdock, M. H., Aggarwal, A., Chang, Y.-F., Wiseman, P. W., Ruthazer, E. S., Boyden, E. S., & Campbell, R. E.
- Venue
- PLOS Biology
- Publisher
- Public Library of Science (PLoS)
- Published
- 2020-11-24
- Volume
- 18
- Issue
- 11
- Pages
- e3000965
- ISSN
- 1544-9173 (ISSN-L)
- 1545-7885
- OpenAlex
- W3107608927
- Cited by
- 92
- References
- 1
- FWCI
- 6.44
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved genetically encoded near-infrared fluorescent calcium ion indicators for in vivo imaging. https://app.cochat.ai/papers/10.1371/journal.pbio.3000965
- The paper
- Qian, Y., Cosio, D. M. O., Piatkevich, K. D., Aufmkolk, S., Su, W.-C., Celiker, O. T., Schohl, A., Murdock, M. H., Aggarwal, A., Chang, Y.-F., Wiseman, P. W., Ruthazer, E. S., Boyden, E. S., & Campbell, R. E. (2020). Improved genetically encoded near-infrared fluorescent calcium ion indicators for in vivo imaging. PLOS Biology. https://doi.org/10.1371/journal.pbio.3000965
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.