Cited by 16Neuroscience and Neural EngineeringEEG and Brain-Computer InterfacesTactile and Sensory Interactions

Advances and challenges in the development of visual prostheses

Open access
Fernandez, Eduardo, Robles, Jose Antonio·2024·PLOS Biology

Abstract

The past 20 years have witnessed significant advancements in the field of visual prostheses, with developments spanning from early retinal implants to recent cortical approaches.This Perspective looks at some of the remaining challenges to achieve the ambitious clinical goals that these technologies could enable.Visual impairment profoundly impacts individuals' lives, compromising personal autonomy and diminishing overall quality of life.Over the last 2 decades, the field has progressed from experimental concepts to clinically available devices [1].This evolution has yielded varying degrees of success, reflecting both advances made and the challenges that remain.The early 2000s marked the beginning of tangible progress in visual prostheses development, particularly with the emergence of retinal implants.The Argus II Retinal Prosthesis System, developed by Second Sight, was one of the first devices to receive regulatory approval [2].The Alpha IMS developed by Retina Implant AG also made significant strides [3].These early systems provided users with a limited form of vision, allowing them to perceive light, shapes, and motion.However, despite the initial promising results, the devices ultimately fell short of unmet expectations, leading to their eventual withdrawal from the market [4].This outcome underscores the complexity of developing visual prostheses and highlights the need for continued research and development in the field.Many of the challenges in the field of visual prostheses are shared with the broader field of neurotechnology and span various aspects of neural interface development and implementation, reflecting the interconnected nature of neuroscientific research and technological innovation [5].To be able to stimulate individual neurons, the microelectrodes should be located very close to target cells and have dimensions similar to the neurons they are trying to stimulate.Likewise, both the electrodes and the substrates housing the connecting pathways must be highly biocompatible and completely insulated.This is crucial to mitigate the foreign body response, prevent degradation, and minimize crosstalk between electrodes.Furthermore, it is important to ensure the mechanical stability of implanted devices over time.Additionally, a significant challenge is the limited ability of current devices to constrain electrical fields to target specific cell types or structures.All these requirements impose unique constraints on the architecture and materials used in the design and implementation of visual prostheses.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pbio.3002896

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Fernandez, E., & Robles, J. A.
Affiliations
Universitat de Miguel Hernández d'Elx (ES)
Corresponding author
Fernandez, Eduardo
Venue
PLOS Biology
Published
2024-10-24
Volume
22
Issue
10
Pages
e3002896
ISSN
  • 1544-9173 (ISSN-L)
  • 1545-7885
OpenAlex
W4403708031
Cited by
16
References
10
Citations by year
2026: 6 · 2025: 9 · 2024: 1
FWCI
2.79
Type
journal article
Language
en
Open access
Locations
  • PLoS Biology (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Radboud Repository (Radboud University) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Ministerio de Ciencia, Innovación y Universidades (PDC2022-133952-100, PID2022-141606OB-I00)
  • Conselleria de Cultura, Educación y Ciencia, Generalitat Valenciana (CIPROM/2023/25)
  • Horizon 2020 Framework Programme (899287)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
Keywords
retinal prosthesis, Argus II, neural interfaces, microelectrodes, biocompatibility, foreign body reaction, mechanical stability, neurotechnology, visual impairment
MeSH terms
Humans, Prosthesis Design, Retina, Visual Cortex, Visual Prosthesis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review