Advances and challenges in the development of visual prostheses
Open accessAbstract
The past 20 years have witnessed significant advancements in the field of visual prostheses, with developments spanning from early retinal implants to recent cortical approaches.This Perspective looks at some of the remaining challenges to achieve the ambitious clinical goals that these technologies could enable.Visual impairment profoundly impacts individuals' lives, compromising personal autonomy and diminishing overall quality of life.Over the last 2 decades, the field has progressed from experimental concepts to clinically available devices [1].This evolution has yielded varying degrees of success, reflecting both advances made and the challenges that remain.The early 2000s marked the beginning of tangible progress in visual prostheses development, particularly with the emergence of retinal implants.The Argus II Retinal Prosthesis System, developed by Second Sight, was one of the first devices to receive regulatory approval [2].The Alpha IMS developed by Retina Implant AG also made significant strides [3].These early systems provided users with a limited form of vision, allowing them to perceive light, shapes, and motion.However, despite the initial promising results, the devices ultimately fell short of unmet expectations, leading to their eventual withdrawal from the market [4].This outcome underscores the complexity of developing visual prostheses and highlights the need for continued research and development in the field.Many of the challenges in the field of visual prostheses are shared with the broader field of neurotechnology and span various aspects of neural interface development and implementation, reflecting the interconnected nature of neuroscientific research and technological innovation [5].To be able to stimulate individual neurons, the microelectrodes should be located very close to target cells and have dimensions similar to the neurons they are trying to stimulate.Likewise, both the electrodes and the substrates housing the connecting pathways must be highly biocompatible and completely insulated.This is crucial to mitigate the foreign body response, prevent degradation, and minimize crosstalk between electrodes.Furthermore, it is important to ensure the mechanical stability of implanted devices over time.Additionally, a significant challenge is the limited ability of current devices to constrain electrical fields to target specific cell types or structures.All these requirements impose unique constraints on the architecture and materials used in the design and implementation of visual prostheses.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Webvision: The Organization of the Retina and Visual System
Kolb, H., Fernández, E., & Nelson, R. (1995) · Cited by 544 · see citing works
da Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359 · see citing works
Edwards, T. L., Cottriall, C. L., Xue, K., Simunovic, M. P., Ramsden, J. D., Zrenner, E., & MacLaren, R. E. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2017.09.019 · Cited by 193 · see citing works
Cochlear Implant Research and Development in the Twenty-first Century: A Critical Update
Carlyon, R. P., & Goehring, T. (2021) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-021-00811-5 · Cited by 156 · see citing works
Development of visual Neuroprostheses: trends and challenges.
Fernandez, E. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0013-8 · Cited by 114 · see citing works
Self-citationDagnelie, G., Barnett, D., Humayun, M. S., & Thompson, R. W. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-0157 · Cited by 90 · see citing works
An update on visual prosthesis
Ramirez, K. A., Drew-Bear, L. E., Vega-Garces, M. I., Belandria, H. B., & Arévalo, J. F. (2023) · International Journal of Retina and Vitreous · doi:10.1186/s40942-023-00498-1 · Cited by 49 · see citing works
Caspi, A., Barry, M. P., Patel, U. K., Salas, M. A., Dorn, J. D., Roy, A., Niketeghad, S., Greenberg, R. J., & Pouratian, N. (2021) · Brain Stimulation · doi:10.1016/j.brs.2021.04.019 · Cited by 32 · see citing works
Strickland, E., & Harris, M. (2022) · IEEE Spectrum · doi:10.1109/mspec.2022.9729945 · Cited by 19 · see citing works
Toward a personalized closed-loop stimulation of the visual cortex: Advances and challenges
Grani, F., Soto-Sánchez, C., Fimia, A., & Fernández, E. (2022) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2022.1034270 · Cited by 16 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Visual Prostheses in the Era of Artificial Intelligence Technology
Sarbout, I., Gungor, A., Ounissi, M., Zaher, S., Ptito, M., Kupers, R., Racoceanu, D., & Milea, D. (2025) · Eye and Brain · doi:10.2147/eb.s524322 · Cited by 3 · see citing works
“The method design must result in an encoding scheme that favors the extraction of salient features and may also encompass optimization of the visual flow by considering models for perception of phosphenes.”
- Authors
- Fernandez, E., & Robles, J. A.
- Affiliations
- Universitat de Miguel Hernández d'Elx (ES)
- Corresponding author
- Fernandez, Eduardo
- Venue
- PLOS Biology
- Publisher
- Public Library of Science (PLoS)
- Published
- 2024-10-24
- Volume
- 22
- Issue
- 10
- Pages
- e3002896
- ISSN
- 1544-9173 (ISSN-L)
- 1545-7885
- PMC
- PMC11616817
- OpenAlex
- W4403708031
- Cited by
- 16
- References
- 10
- Citations by year
- 2026: 6 · 2025: 9 · 2024: 1
- FWCI
- 2.79
- Type
- journal article
- Language
- en
- Update notices
- new_version (2024-12-04)
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS Biology (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Radboud Repository (Radboud University) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Ministerio de Ciencia, Innovación y Universidades (PDC2022-133952-100, PID2022-141606OB-I00)
- Conselleria de Cultura, Educación y Ciencia, Generalitat Valenciana (CIPROM/2023/25)
- Horizon 2020 Framework Programme (899287)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Keywords
- retinal prosthesis, Argus II, neural interfaces, microelectrodes, biocompatibility, foreign body reaction, mechanical stability, neurotechnology, visual impairment
- MeSH terms
- Humans, Prosthesis Design, Retina, Visual Cortex, Visual Prosthesis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review