The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Effects of Two Commercial Electronic Prescribing Systems on Prescribing Error Rates in Hospital In-Patients: A Before and After Study
Open accessAbstract
BACKGROUND: Considerable investments are being made in commercial electronic prescribing systems (e-prescribing) in many countries. Few studies have measured or evaluated their effectiveness at reducing prescribing error rates, and interactions between system design and errors are not well understood, despite increasing concerns regarding new errors associated with system use. This study evaluated the effectiveness of two commercial e-prescribing systems in reducing prescribing error rates and their propensities for introducing new types of error. METHODS AND RESULTS: We conducted a before and after study involving medication chart audit of 3,291 admissions (1,923 at baseline and 1,368 post e-prescribing system) at two Australian teaching hospitals. In Hospital A, the Cerner Millennium e-prescribing system was implemented on one ward, and three wards, which did not receive the e-prescribing system, acted as controls. In Hospital B, the iSoft MedChart system was implemented on two wards and we compared before and after error rates. Procedural (e.g., unclear and incomplete prescribing orders) and clinical (e.g., wrong dose, wrong drug) errors were identified. Prescribing error rates per admission and per 100 patient days; rates of serious errors (5-point severity scale, those ≥3 were categorised as serious) by hospital and study period; and rates and categories of postintervention "system-related" errors (where system functionality or design contributed to the error) were calculated. Use of an e-prescribing system was associated with a statistically significant reduction in error rates in all three intervention wards (respectively reductions of 66.1% [95% CI 53.9%-78.3%]; 57.5% [33.8%-81.2%]; and 60.5% [48.5%-72.4%]). The use of the system resulted in a decline in errors at Hospital A from 6.25 per admission (95% CI 5.23-7.28) to 2.12 (95% CI 1.71-2.54; p<0.0001) and at Hospital B from 3.62 (95% CI 3.30-3.93) to 1.46 (95% CI 1.20-1.73; p<0.0001). This decrease was driven by a large reduction in unclear, illegal, and incomplete orders. The Hospital A control wards experienced no significant change (respectively -12.8% [95% CI -41.1% to 15.5%]; -11.3% [-40.1% to 17.5%]; -20.1% [-52.2% to 12.4%]). There was limited change in clinical error rates, but serious errors decreased by 44% (0.25 per admission to 0.14; p = 0.0002) across the intervention wards compared to the control wards (17% reduction; 0.30-0.25; p = 0.40). Both hospitals experienced system-related errors (0.73 and 0.51 per admission), which accounted for 35% of postsystem errors in the intervention wards; each system was associated with different types of system-related errors. CONCLUSIONS: Implementation of these commercial e-prescribing systems resulted in statistically significant reductions in prescribing error rates. Reductions in clinical errors were limited in the absence of substantial decision support, but a statistically significant decline in serious errors was observed. System-related errors require close attention as they are frequent, but are potentially remediable by system redesign and user training. Limitations included a lack of control wards at Hospital B and an inability to randomize wards to the intervention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bates, D. W. (1998) · JAMA · doi:10.1001/jama.280.15.1311 · Cited by 2,107
Ash, J. S. (2003) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1471 · Cited by 1,789
The Impact of eHealth on the Quality and Safety of Health Care: A Systematic Overview
Black, A. D., Car, J., Pagliari, C., Anandan, C., Cresswell, K., Bokun, T., McKinstry, B., Procter, R., Majeed, A., & Sheikh, A. (2011) · PLoS Medicine · doi:10.1371/journal.pmed.1000387 · Cited by 1,442
The Impact of Computerized Physician Order Entry on Medication Error Prevention
Bates, D. W., Teich, J. M., Lee, J., Seger, D., Kuperman, G. J., Ma'Luf, N., Boyle, D., & Leape, L. (1999) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.1999.00660313 · Cited by 1,260
Preventing Medication Errors: Quality Chasm Series
(2007) · doi:10.17226/11623 · Cited by 829
Improving Outcomes with Clinical Decision Support: An Implementer's Guide, Second Edition
Osheroff, J. (2012) · doi:10.4324/9781498757461 · Cited by 517
Evaluating eHealth Interventions: The Need for Continuous Systemic Evaluation
Catwell, L., & Sheikh, A. (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000126 · Cited by 307
Why Do Evaluations of eHealth Programs Fail? An Alternative Set of Guiding Principles
Greenhalgh, T., & Russell, J. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000360 · Cited by 273 · cited 1×
“However, as other studies have demonstrated [40,43,44], success in achieving this outcome is dependent upon many contextual and organisational factors and multimethod studies are of great value in order to understand the mechanisms by which e-prescribing systems impact upon prescribing behaviours [12].”
ResultA Consensus Statement on Considerations for a Successful CPOE Implementation
Ash, J. S. (2003) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1204 · Cited by 239
Elwyn, G., Légaré, F., Weijden, T. V. D., Edwards, A., & May, C. (2008) · Implementation Science · doi:10.1186/1748-5908-3-57 · Cited by 159
Evaluating eHealth: How to Make Evaluation More Methodologically Robust
Lilford, R. J., Foster, J., & Pringle, M. (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000186 · Cited by 79
Cited by
Nuckols, T. K., Smith-Spangler, C., Morton, S. C., Asch, S. M., Patel, V. M., Anderson, L. J., Deichsel, E. L., & Shekelle, P. G. (2014) · Systematic Reviews · doi:10.1186/2046-4053-3-56 · Cited by 340
“Nine studies assessed commercially developed CPOE systems [11,49,50,54,55,61,64,65,70], six evaluated homegrown systems [53,58,59,63,66,68], and one examined both [60].”
BackgroundInfluentialWestbrook, J. I., Raban, M. Z., Walter, S. R., & Douglas, H. (2018) · BMJ Quality & Safety · doi:10.1136/bmjqs-2017-007333 · Cited by 317
Self-citationKim, M. O., Coiera, E., & Magrabi, F. (2017) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocw154 · Cited by 263
Automation bias in electronic prescribing
Lyell, D., Magrabi, F., Raban, M. Z., Pont, L. G., Baysari, M. T., Day, R. O., & Coiera, E. (2017) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-017-0425-5 · Cited by 103
Self-citationThe unintended consequences of health information technology revisited
Ash, J., Berg, M., & Coiera, E. (2016) · Yearbook of Medical Informatics · doi:10.15265/iy-2016-014 · Cited by 101
“Using a standardized workflow measurement tool and error categorization scheme, Westbrook and colleagues undertook detailed analyses of medication error rates before and after the introduction of a CPOE system in two hospitals [33 34].”
Metadata
- Authors
- Westbrook, J. I., Reckmann, M., Li, L., Runciman, W. B., Burke, R., Lo, C., Baysari, M. T., Braithwaite, J., & Day, R. O.
- Venue
- PLoS Medicine
- Publisher
- Public Library of Science (PLoS)
- Published
- 2012-01-31
- Volume
- 9
- Issue
- 1
- Pages
- e1001164
- ISSN
- 1549-1277 (ISSN-L)
- 1549-1676
- OpenAlex
- W1994326995
- Cited by
- 216
- References
- 11
- FWCI
- 34.71
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.