CoChat

Mathematical Analysis of Copy Number Variation in a DNA Sample Using Digital PCR on a Nanofluidic Device

Open access

The DOI matches its Crossref record; 27 of the 30 references it cites were found in a registry or an index.

Abstract

Copy Number Variations (CNVs) of regions of the human genome have been associated with multiple diseases. We present an algorithm which is mathematically sound and computationally efficient to accurately analyze CNV in a DNA sample utilizing a nanofluidic device, known as the digital array. This numerical algorithm is utilized to compute copy number variation and the associated statistical confidence interval and is based on results from probability theory and statistics. We also provide formulas which can be used as close approximations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0002876

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 A digital array has 12 panels of 765 reaction chambers each. PCR mixes are loaded into each panel and single DNA molecules are randomly partitioned into the chambers. The digital array can be thermocycled, imaged on a BioMark instrument, and the data analyzed using the Digital PCR Analysis software.
Figure 1 A digital array has 12 panels of 765 reaction chambers each. PCR mixes are loaded into each panel and single DNA molecules are randomly partitioned into the chambers. The digital array can be thermocycled, imaged on a BioMark instrument, and the data analyzed using the Digital PCR Analysis software.CC BY · PubMed Central
Figure 2 Human genomic DNA NA10860 (left 5 panels) and the RPP30 synthetic construct (right 5 panels) were quantitated using the RPP30 (FAM) assay on this digital array. The two bottom panels are NTC (no template control). Digital PCR Analysis software can count the number of positive chambers in each panel. When two assays with two fluorescent dyes are used in a multiplex digital PCR reaction, two genes can be independently quantitated. This is the basis of the CNV study using the digital array.
Figure 2 Human genomic DNA NA10860 (left 5 panels) and the RPP30 synthetic construct (right 5 panels) were quantitated using the RPP30 (FAM) assay on this digital array. The two bottom panels are NTC (no template control). Digital PCR Analysis software can count the number of positive chambers in each panel. When two assays with two fluorescent dyes are used in a multiplex digital PCR reaction, two genes can be independently quantitated. This is the basis of the CNV study using the digital array.CC BY · PubMed Central
Figure 3 Consider an infinite universe of chambers. A digital array panel is a finite sampling of this universe. The goal is to determine λ, the mean number of the target molecules per chamber in the DNA sample. The number of positive chambers, which have hits of one or more molecules, shown as filled green squares in the panel with C( = 765) chambers is H.
Figure 3 Consider an infinite universe of chambers. A digital array panel is a finite sampling of this universe. The goal is to determine λ, the mean number of the target molecules per chamber in the DNA sample. The number of positive chambers, which have hits of one or more molecules, shown as filled green squares in the panel with C( = 765) chambers is H.CC BY · PubMed Central
Figure 4 From the sampling distribution of estimation of p, one can obtain the sampling distribution of estimation of λ.
Figure 4 From the sampling distribution of estimation of p, one can obtain the sampling distribution of estimation of λ.CC BY · PubMed Central
Figure 5 Histogram of number of positive chambers H = P×C obtained by choosing M = 400 as the mean number of molecules per panel over 70 thousand panels and running a simulation using a random number generator. The green curve is the sampling distribution predicted by the theory.
Figure 5 Histogram of number of positive chambers H = P×C obtained by choosing M = 400 as the mean number of molecules per panel over 70 thousand panels and running a simulation using a random number generator. The green curve is the sampling distribution predicted by the theory.CC BY · PubMed Central
Figure 6 Geometric interpretation of Fieller's Theorem to compute confidence interval of ratio of two normally distributed random variables and in which confidence ellipse of the joint sampling distribution is projected on a vertical line.
Figure 6 Geometric interpretation of Fieller's Theorem to compute confidence interval of ratio of two normally distributed random variables and in which confidence ellipse of the joint sampling distribution is projected on a vertical line.CC BY · PubMed Central
Figure 7 Illustration of a numerical projection algorithm to compute the sampling distribution of ratio of two random variables with arbitrary probability distributions by slicing the 2-D space into thin wedges and accumulating the joint probabilities in the wedges. Most of the contribution would come from the confidence ellipse region.
Figure 7 Illustration of a numerical projection algorithm to compute the sampling distribution of ratio of two random variables with arbitrary probability distributions by slicing the 2-D space into thin wedges and accumulating the joint probabilities in the wedges. Most of the contribution would come from the confidence ellipse region.CC BY · PubMed Central
Figure 8 Results of actual CNV experiments on the digital array with varying number of copies of the target gene. In total, 6 different known ratios were estimated by running the experiments for varying number of panels. The graphs for different numbers of copies are slightly staggered to allow visual comparison of overlap of the 95% confidence intervals.
Figure 8 Results of actual CNV experiments on the digital array with varying number of copies of the target gene. In total, 6 different known ratios were estimated by running the experiments for varying number of panels. The graphs for different numbers of copies are slightly staggered to allow visual comparison of overlap of the 95% confidence intervals.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 303

Metadata

Authors
Dube, S., Qin, J., & Ramakrishnan, R.
Affiliations
Standard BioTools (United States) (US)
Corresponding author
Dube, Simant
Venue
PLoS ONE
Published
2008-08-06
Volume
3
Issue
8
Pages
e2876
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2143297413
Cited by
302
References
30
Citations by year
2026: 11 · 2025: 11 · 2024: 13 · 2023: 20 · 2022: 23 · 2021: 19 · 2020: 23 · 2019: 17 · 2018: 21 · 2017: 14 · 2016: 30 · 2015: 23 · 2014: 16 · 2013: 16 · 2012: 13
FWCI
7.08
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Genomic variations and chromosomal abnormalities
  • Physical Sciences › Engineering › Biomedical Engineering › Nanopore and Nanochannel Transport Studies
Keywords
copy number variation, digital PCR, nanofluidic devices, confidence intervals, numerical algorithms, human genome
MeSH terms
Algorithms, DNA, Humans, Models, Genetic, Genetic Variation, Genome, Human, Confidence Intervals, Polymerase Chain Reaction, Oligonucleotide Array Sequence Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.