Speeded Near Infrared Spectroscopy (NIRS) Response Detection
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The hemodynamic response measured by Near Infrared Spectroscopy (NIRS) is temporally delayed from the onset of the underlying neural activity. As a consequence, NIRS based brain-computer-interfaces (BCIs) and neurofeedback learning systems, may have a latency of several seconds in responding to a change in participants' behavioral or mental states, severely limiting the practical use of such systems. To explore the possibility of reducing this delay, we used a multivariate pattern classification technique (linear support vector machine, SVM) to decode the true behavioral state from the measured neural signal and systematically evaluated the performance of different feature spaces (signal history, history gradient, oxygenated or deoxygenated hemoglobin signal and spatial pattern). We found that the latency to decode a change in behavioral state can be reduced by 50% (from 4.8 s to 2.4 s), which will enhance the feasibility of NIRS for real-time applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neurophysiological investigation of the basis of the fMRI signal
Logothetis, N. K., Pauls, J., Augath, M., Trinath, T., & Oeltermann, A. (2001) · Nature · doi:10.1038/35084005 · Cited by 6,551 · cited 1×
“NIRS measures changes in local concentration of oxygenated and deoxygenated hemoglobin (oxy-Hb and deoxy-Hb) in the cerebral blood. This signal is strongly related to the BOLD signal measured with fMRI, and shows similar temporal dynamics”
BackgroundControl over brain activation and pain learned by using real-time functional MRI
deCharms, R. C., Maeda, F., Glover, G. H., Ludlow, D., Pauly, J. M., Soneji, D., Gabrieli, J. D. E., & Mackey, S. C. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0505210102 · Cited by 876
Cognitive Control Signals for Neural Prosthetics
Musallam, S., Corneil, B. D., Greger, B., Scherberger, H., & Andersen, R. A. (2004) · Science · doi:10.1126/science.1097938 · Cited by 663 · cited 1×
“Multivariate pattern classification techniques have been applied to BCI systems across many modalities [1,7].”
MethodThe thought translation device (TTD) for completely paralyzed patients
Birbaumer, N., Kubler, A., Ghanayim, N., Hinterberger, T., Perelmouter, J., Kaiser, J., Iversen, I., Kotchoubey, B., Neumann, N., & Flor, H. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847812 · Cited by 493
Devor, A., Dunn, A. K., Andermann, M. L., Ulbert, I., Boas, D. A., & Dale, A. M. (2003) · Neuron · doi:10.1016/s0896-6273(03)00403-3 · Cited by 387
Cited by
fNIRS-based brain-computer interfaces: a review
Naseer, N., & Hong, K.-S. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00003 · Cited by 988
Herold, F., Wiegel, P., Scholkmann, F., & Müller, N. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7120466 · Cited by 482
Mental workload during n-back task—quantified in the prefrontal cortex using fNIRS
Herff, C., Heger, D., Fortmann, O., Hennrich, J., Putze, F., & Schultz, T. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00935 · Cited by 365
Feature Extraction and Classification Methods for Hybrid fNIRS-EEG Brain-Computer Interfaces
Hong, K.-S., Khan, M. J., & Hong, M. J. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00246 · Cited by 283
Dynamic difficulty using brain metrics of workload
Afergan, D., Peck, E. M., Solovey, E. T., Jenkins, A., Hincks, S. W., Brown, E. T., Chang, R., & Jacob, R. J. K. (2014) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/2556288.2557230 · Cited by 148
Metadata
- Authors
- Cui, X., Bray, S., & Reiss, A. L.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2010-11-11
- Volume
- 5
- Issue
- 11
- Pages
- e15474
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2149351353
- Cited by
- 133
- References
- 5
- FWCI
- 4.82
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.