Calibration Belt for Quality-of-Care Assessment Based on Dichotomous Outcomes
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Prognostic models applied in medicine must be validated on independent samples, before their use can be recommended. The assessment of calibration, i.e., the model's ability to provide reliable predictions, is crucial in external validation studies. Besides having several shortcomings, statistical techniques such as the computation of the standardized mortality ratio (SMR) and its confidence intervals, the Hosmer-Lemeshow statistics, and the Cox calibration test, are all non-informative with respect to calibration across risk classes. Accordingly, calibration plots reporting expected versus observed outcomes across risk subsets have been used for many years. Erroneously, the points in the plot (frequently representing deciles of risk) have been connected with lines, generating false calibration curves. Here we propose a methodology to create a confidence band for the calibration curve based on a function that relates expected to observed probabilities across classes of risk. The calibration belt allows the ranges of risk to be spotted where there is a significant deviation from the ideal calibration, and the direction of the deviation to be indicated. This method thus offers a more analytical view in the assessment of quality of care, compared to other approaches.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Gall, J.-R. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.270.24.2957 · Cited by 7,773
Donabedian, A. (1988) · JAMA · doi:10.1001/jama.260.12.1743 · Cited by 5,895 · cited 1×
“Fair, reliable evaluation of quality of care has always been a crucial but difficult task. According to the classical approach proposed by Donabedian”
A REVIEW OF GOODNESS OF FIT STATISTICS FOR USE IN THE DEVELOPMENT OF LOGISTIC REGRESSION MODELS1
LEMESHOW, S., & HOSMER, D. W. (1982) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a113284 · Cited by 1,947
Kramer, A. A., & Zimmerman, J. E. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000275267.64078.b0 · Cited by 886 · cited 1×
“The main limitations of this approach [4,5] are overcome by Cox calibration analysis [6,7], although this method is less popular.”
MethodTwo Further Applications of a Model for Binary Regression
Cox, D. R. (1958) · Biometrika · doi:10.2307/2333203 · Cited by 557
Two further applications of a model for binary regression
COX, D. R. (1958) · Biometrika · doi:10.1093/biomet/45.3-4.562 · Cited by 556
Cited by
Predicting 5- and 10-year mortality risk in older adults with diabetes
Griffith, K. N., Prentice, J. C., Mohr, D. C., & Conlin, P. R. (2020) · Diabetes Care · doi:10.2337/dc19-1870 · Cited by 48
Bootstrap confidence intervals for loess-based calibration curves
Austin, P. C., & Steyerberg, E. W. (2014) · Statistics in Medicine · doi:10.1002/sim.6167 · Cited by 19
“In their letter, NFB described the use of a new graphical method, known as the calibration belt, to assess calibration [2, 3].”
MethodGazda, J., Janicko, M., Drazilova, S., Grgurevic, I., Kanizaj, T. F., Koller, T., Bodorovska, B., Mijic, M., Mikolasevic, I., Stromar, I. K., et al. (2021) · Canadian Journal of Gastroenterology and Hepatology · doi:10.1155/2021/9928065 · Cited by 6
Metadata
- Authors
- Finazzi, S., Poole, D., Luciani, D., Cogo, P. E., & Bertolini, G.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2011-02-23
- Volume
- 6
- Issue
- 2
- Pages
- e16110
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2054950265
- Cited by
- 162
- References
- 6
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calibration Belt for Quality-of-Care Assessment Based on Dichotomous Outcomes. https://app.cochat.ai/papers/10.1371/journal.pone.0016110
- The paper
- Finazzi, S., Poole, D., Luciani, D., Cogo, P. E., & Bertolini, G. (2011). Calibration Belt for Quality-of-Care Assessment Based on Dichotomous Outcomes. PLoS ONE. https://doi.org/10.1371/journal.pone.0016110
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.