CoChat

Mass Spectrometry Analysis of Hepcidin Peptides in Experimental Mouse Models

Open access
Tjalsma, Harold, Laarakkers, Coby M. M., van Swelm, Rachel P. L., Theurl, Milan, Theurl, Igor, Kemna, Erwin H., van der Burgt, Yuri E. M., Venselaar, Hanka, Dutilh, Bas E., Russel, Frans G. M., Weiss, Günter, Masereeuw, Rosalinde, Fleming, Robert E., Swinkels, Dorine W. · 2011 · PLoS ONE
Cited by 30

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

The mouse is a valuable model for unravelling the role of hepcidin in iron homeostasis, however, such studies still report hepcidin mRNA levels as a surrogate marker for bioactive hepcidin in its pivotal function to block ferroportin-mediated iron transport. Here, we aimed to assess bioactive mouse Hepcidin-1 (Hep-1) and its paralogue Hepcidin-2 (Hep-2) at the peptide level. To this purpose, Fourier transform ion cyclotron resonance (FTICR) and tandem-MS was used for hepcidin identification, after which a time-of-flight (TOF) MS-based methodology was exploited to routinely determine Hep-1 and -2 levels in mouse serum and urine. This method was biologically validated by hepcidin assessment in: i) 3 mouse strains (C57Bl/6; DBA/2 and BABL/c) upon stimulation with intravenous iron and LPS, ii) homozygous Hfe knock out, homozygous transferrin receptor 2 (Y245X) mutated mice and double affected mice, and iii) mice treated with a sublethal hepatotoxic dose of paracetamol. The results showed that detection of Hep-1 was restricted to serum, whereas Hep-2 and its presumed isoforms were predominantly present in urine. Elevations in serum Hep-1 and urine Hep-2 upon intravenous iron or LPS were only moderate and varied considerably between mouse strains. Serum Hep-1 was decreased in all three hemochromatosis models, being lowest in the double affected mice. Serum Hep-1 levels correlated with liver hepcidin-1 gene expression, while acute liver damage by paracetamol depleted Hep-1 from serum. Furthermore, serum Hep-1 appeared to be an excellent indicator of splenic iron accumulation. In conclusion, Hep-1 and Hep-2 peptide responses in experimental mouse agree with the known biology of hepcidin mRNA regulators, and their measurement can now be implemented in experimental mouse models to provide novel insights in post-transcriptional regulation, hepcidin function, and kinetics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0016762

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 30

Metadata

Authors
Tjalsma, H., Laarakkers, C. M. M., van Swelm, R. P. L., Theurl, M., Theurl, I., Kemna, E. H., van der Burgt, Y. E. M., Venselaar, H., Dutilh, B. E., Russel, F. G. M., Weiss, G., Masereeuw, R., Fleming, R. E., & Swinkels, D. W.
Venue
PLoS ONE
Published
2011-03-08
Volume
6
Issue
3
Pages
e16762
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2073354871
Cited by
30
References
15
FWCI
3.40
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mass Spectrometry Analysis of Hepcidin Peptides in Experimental Mouse Models. https://app.cochat.ai/papers/10.1371/journal.pone.0016762
The paper
Tjalsma, H., Laarakkers, C. M. M., van Swelm, R. P. L., Theurl, M., Theurl, I., Kemna, E. H., van der Burgt, Y. E. M., Venselaar, H., Dutilh, B. E., Russel, F. G. M., Weiss, G., Masereeuw, R., Fleming, R. E., & Swinkels, D. W. (2011). Mass Spectrometry Analysis of Hepcidin Peptides in Experimental Mouse Models. PLoS ONE. https://doi.org/10.1371/journal.pone.0016762

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.