CoChat

Perceiving Nasal Patency through Mucosal Cooling Rather than Air Temperature or Nasal Resistance

Open access

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

Adequate perception of nasal airflow (i.e., nasal patency) is an important consideration for patients with nasal sinus diseases. The perception of a lack of nasal patency becomes the primary symptom that drives these patients to seek medical treatment. However, clinical assessment of nasal patency remains a challenge because we lack objective measurements that correlate well with what patients perceive. The current study examined factors that may influence perceived patency, including air temperature, humidity, mucosal cooling, nasal resistance, and trigeminal sensitivity. Forty-four healthy subjects rated nasal patency while sampling air from three facial exposure boxes that were ventilated with untreated room air, cold air, and dry air, respectively. In all conditions, air temperature and relative humidity inside each box were recorded with sensors connected to a computer. Nasal resistance and minimum airway cross-sectional area (MCA) were measured using rhinomanometry and acoustic rhinometry, respectively. General trigeminal sensitivity was assessed through lateralization thresholds to butanol. No significant correlation was found between perceived patency and nasal resistance or MCA. In contrast, air temperature, humidity, and butanol threshold combined significantly contributed to the ratings of patency, with mucosal cooling (heat loss) being the most heavily weighted predictor. Air humidity significantly influences perceived patency, suggesting that mucosal cooling rather than air temperature alone provides the trigeminal sensation that results in perception of patency. The dynamic cooling between the airstream and the mucosal wall may be quantified experimentally or computationally and could potentially lead to a new clinical evaluation tool.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0024618

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Temperature (left) and relative humidity (right) measurement during each subject exposure session. The temperature in the cold air exposure box was significantly lower than in the other exposure boxes, and the RH in the dry air exposure box was significantly lower than in the others (both p<0.01). The temperature difference between room air and dry air and the humidity difference between room air and cold air were both non-significant.
Figure 1 Temperature (left) and relative humidity (right) measurement during each subject exposure session. The temperature in the cold air exposure box was significantly lower than in the other exposure boxes, and the RH in the dry air exposure box was significantly lower than in the others (both p<0.01). The temperature difference between room air and dry air and the humidity difference between room air and cold air were both non-significant.CC BY · PubMed Central
Figure 2 Air exposure boxes and the visual analog scale used in the study. The visual analogue scale includes a negative range to account for subjects that may rate their nasal patency as completely clear and then experience even less congestion in later exposures.
Figure 2 Air exposure boxes and the visual analog scale used in the study. The visual analogue scale includes a negative range to account for subjects that may rate their nasal patency as completely clear and then experience even less congestion in later exposures.CC BY · PubMed Central
Figure 3 Flow chart of the test sequence for each participant: box exposure and patency rating (top), followed by rhinometry, rhinomanometry, and trigeminal assessment by butanol lateralization threshold (bottom).
Figure 3 Flow chart of the test sequence for each participant: box exposure and patency rating (top), followed by rhinometry, rhinomanometry, and trigeminal assessment by butanol lateralization threshold (bottom).CC BY · PubMed Central
Figure 4 Bilateral and unilateral subjective patency ratings and standard errors in room air, dry air, and cold air exposure boxes. Subjects perceived significantly less nasal congestion (greater patency), both unilaterally and bilaterally, in the cold air box and unilaterally in the dry air box, compared to the room air box (p<0.01), with the cold air box having a larger effect (p<0.01) (Wilcoxon match pairs test, with Holm–Bonferroni correction to control for multiple comparison.)
Figure 4 Bilateral and unilateral subjective patency ratings and standard errors in room air, dry air, and cold air exposure boxes. Subjects perceived significantly less nasal congestion (greater patency), both unilaterally and bilaterally, in the cold air box and unilaterally in the dry air box, compared to the room air box (p<0.01), with the cold air box having a larger effect (p<0.01) (Wilcoxon match pairs test, with Holm–Bonferroni correction to control for multiple comparison.)CC BY · PubMed Central
Figure 5 Averaged total nasal heat loss versus patency visual analog scale (VAS) ratings for the three exposure box conditions. Nasal heat loss is calculated assuming that, at the end of the breath, inspired air is always warmed and humidified to 35°C and 90% RH [13], [14]. Data are averaged over subjects for the three exposure conditions.
Figure 5 Averaged total nasal heat loss versus patency visual analog scale (VAS) ratings for the three exposure box conditions. Nasal heat loss is calculated assuming that, at the end of the breath, inspired air is always warmed and humidified to 35°C and 90% RH [13], [14]. Data are averaged over subjects for the three exposure conditions.CC BY · PubMed Central
Figure 6 Within subject, there was a significant difference in perceived patency between the high and low resistance nostrils.
Figure 6 Within subject, there was a significant difference in perceived patency between the high and low resistance nostrils.CC BY · PubMed Central
Figure 7 Contour plot of nasal mucosal heat flux (J/m2) for a subject that received a nasal/sinus CT scan immediately before testing. A CFD model was created for this subject using the method described by Zhao et al. [16] in which nasal airflow and mucosal heat exchange are then simulated. The wall boundary condition at the mucosal surface is set similar to that described by Naftali et al. [14]: fully saturated with water vapor and at body temperature, with an unlimited supply of heat and water vapor.
Figure 7 Contour plot of nasal mucosal heat flux (J/m2) for a subject that received a nasal/sinus CT scan immediately before testing. A CFD model was created for this subject using the method described by Zhao et al. [16] in which nasal airflow and mucosal heat exchange are then simulated. The wall boundary condition at the mucosal surface is set similar to that described by Naftali et al. [14]: fully saturated with water vapor and at body temperature, with an unlimited supply of heat and water vapor.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Research works printed but not linked: 1

  1. T Voets, 2007, TRPM8., HEP, 179, 329

Cited by

See all 151

Metadata

Authors
Zhao, K., Blacker, K., Luo, Y., Bryant, B., & Jiang, J.
Affiliations
Monell Chemical Senses Center (US)
Corresponding author
Zhao, Kai
Venue
PLoS ONE
Published
2011-10-13
Volume
6
Issue
10
Pages
e24618
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2096605630
Cited by
151
References
28
Citations by year
2026: 4 · 2025: 4 · 2024: 16 · 2023: 25 · 2022: 15 · 2021: 15 · 2020: 13 · 2019: 13 · 2018: 8 · 2017: 15 · 2016: 7 · 2015: 5 · 2014: 8 · 2013: 3
FWCI
3.57
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • National Institutes of Health (5p50dc006760-05, NIH P50)
  • National Institute on Deafness and Other Communication Disorders (P50-DC006760, P50 DC00006760, R03DC008187)
Topics
  • Health Sciences › Medicine › Surgery › Nasal Surgery and Airway Studies
  • Health Sciences › Medicine › Otorhinolaryngology › Sinusitis and nasal conditions
  • Life Sciences › Neuroscience › Sensory Systems › Olfactory and Sensory Function Studies
Keywords
nasal patency, air temperature, relative humidity, nasal resistance, trigeminal sensitivity, paranasal sinus disease, rhinomanometry, acoustic rhinometry, patient-reported symptoms
MeSH terms
Adult, Air, Airway Resistance, Body Temperature Regulation, Cold Temperature, Female, Humans, Humidity, Male, Middle Aged, Nasal Mucosa, Pain Measurement, Perception, Rhinomanometry, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Perceiving Nasal Patency through Mucosal Cooling Rather than Air Temperature or Nasal Resistance. https://app.cochat.ai/papers/10.1371/journal.pone.0024618
The paper
Zhao, K., Blacker, K., Luo, Y., Bryant, B., & Jiang, J. (2011). Perceiving Nasal Patency through Mucosal Cooling Rather than Air Temperature or Nasal Resistance. PLoS ONE. https://doi.org/10.1371/journal.pone.0024618

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.