Automated Detection and Segmentation of Synaptic Contacts in Nearly Isotropic Serial Electron Microscopy Images
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
We describe a protocol for fully automated detection and segmentation of asymmetric, presumed excitatory, synapses in serial electron microscopy images of the adult mammalian cerebral cortex, taken with the focused ion beam, scanning electron microscope (FIB/SEM). The procedure is based on interactive machine learning and only requires a few labeled synapses for training. The statistical learning is performed on geometrical features of 3D neighborhoods of each voxel and can fully exploit the high z-resolution of the data. On a quantitative validation dataset of 111 synapses in 409 images of 1948×1342 pixels with manual annotations by three independent experts the error rate of the algorithm was found to be comparable to that of the experts (0.92 recall at 0.89 precision). Our software offers a convenient interface for labeling the training data and the possibility to visualize and proofread the results in 3D. The source code, the test dataset and the ground truth annotation are freely available on the website http://www.ilastik.org/synapse-detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
An empirical comparison of supervised learning algorithms
Caruana, R., & Niculescu-Mizil, A. (2006) · Proceedings of the 23rd international conference on Machine learning - ICML '06 · doi:10.1145/1143844.1143865 · Cited by 2,780
Serial section scanning electron microscopy of adult brain tissue using focused ion beam milling
Knott, G., Marchman, H., Wall, D., & Lich, B. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.3189-07.2008 · Cited by 692
Self-citationConvolutional Networks Can Learn to Generate Affinity Graphs for Image Segmentation
Turaga, S. C., Murray, J. F., Jain, V., Roth, F., Helmstaedter, M., Briggman, K., Denk, W., & Seung, H. S. (2010) · Neural Computation · doi:10.1162/neco.2009.10-08-881 · Cited by 376
Cardona, A., Saalfeld, S., Preibisch, S., Schmid, B., Cheng, A., Pulokas, J., Tomancak, P., & Hartenstein, V. (2010) · PLoS Biology · doi:10.1371/journal.pbio.1000502 · Cited by 372 · cited 1×
“TrakEM2 plug-in of the FIJI framework [31] was Figure 3.”
BackgroundMerchan-Pérez, A. (2009) · Frontiers in Neuroanatomy · doi:10.3389/neuro.05.018.2009 · Cited by 191 · cited 1×
“A protocol for manual synapse detection in FIB/SEM data has recently been proposed in [7].”
Method
Cited by
Hammond, T. R., Dufort, C., Dissing-Olesen, L., Giera, S., Young, A., Wysoker, A., Walker, A. J., Segel, M., Nemesh, J., Saunders, A., et al. (2018) · doi:10.1101/406140 · Cited by 2,225
Quantitative neuroanatomy for connectomics in Drosophila
Schneider-Mizell, C. M., Gerhard, S., Longair, M., Kazimiers, T., Li, F., Zwart, M. F., Champion, A., Midgley, F. M., Fetter, R. D., Saalfeld, S., et al. (2016) · eLife · doi:10.7554/elife.12059 · Cited by 332
A Review of User Interface Design for Interactive Machine Learning
Dudley, J. J., & Kristensson, P. O. (2018) · ACM Transactions on Interactive Intelligent Systems · doi:10.1145/3185517 · Cited by 343
Exploring the third dimension: Volume electron microscopy comes of age
Peddie, C. J., & Collinson, L. M. (2014) · Micron · doi:10.1016/j.micron.2014.01.009 · Cited by 330
Cellular-resolution connectomics: challenges of dense neural circuit reconstruction
Helmstaedter, M. (2013) · Nature Methods · doi:10.1038/nmeth.2476 · Cited by 313
Whole-cell organelle segmentation in volume electron microscopy
Heinrich, L., Bennett, D., Ackerman, D., Park, W., Bogovic, J., Eckstein, N., Petruncio, A., Clements, J., Pang, S., Xu, C. S., et al. (2021) · Nature · doi:10.1038/s41586-021-03977-3 · Cited by 292
Load Adaptation of Lamellipodial Actin Networks
Mueller, J., Szep, G., Nemethova, M., de Vries, I., Lieber, A. D., Winkler, C., Kruse, K., Small, J. V., Schmeiser, C., Keren, K., et al. (2017) · Cell · doi:10.1016/j.cell.2017.07.051 · Cited by 245
Machine Learning of Hierarchical Clustering to Segment 2D and 3D Images
Nunez-Iglesias, J., Kennedy, R., Parag, T., Shi, J., & Chklovskii, D. B. (2013) · PLoS ONE · doi:10.1371/journal.pone.0071715 · Cited by 170
“Classifier predictions for synapses and vesicles might give further improvements [42].”
BackgroundAutomated synaptic connectivity inference for volume electron microscopy
Dorkenwald, S., Schubert, P. J., Killinger, M. F., Urban, G., Mikula, S., Svara, F., & Kornfeld, J. (2017) · Nature Methods · doi:10.1038/nmeth.4206 · Cited by 132
Heinrich, L., Funke, J., Pape, C., Nunez-Iglesias, J., & Saalfeld, S. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-00934-2_36 · Cited by 117
A resource for the Drosophila antennal lobe provided by the connectome of glomerulus VA1v
Horne, J. A., Langille, C., McLin, S., Wiederman, M., Lu, Z., Xu, C. S., Plaza, S. M., Scheffer, L. K., Hess, H. F., & Meinertzhagen, I. A. (2018) · eLife · doi:10.7554/elife.37550 · Cited by 46
“To demarcate the specific glomerulus we first used an algorithm that identified the presynaptic organelles, T-bar ribbons (Fröhlich, 1985; Hamanaka and Meinertzhagen, 2010), to enable large-scale, automated imaging of synaptic contacts (Huang and Plaza, 2014; Kreshuk et al., 2011).”
MethodSynEM, automated synapse detection for connectomics
Staffler, B., Berning, M., Boergens, K. M., Gour, A., Smagt, P. V. D., & Helmstaedter, M. (2017) · eLife · doi:10.7554/elife.26414 · Cited by 57
Fully-Automatic Synapse Prediction and Validation on a Large Data Set
Huang, G. B., Scheffer, L. K., & Plaza, S. M. (2018) · Frontiers in Neural Circuits · doi:10.3389/fncir.2018.00087 · Cited by 46
“An automated approach for synapse identification in EM images using machine learning was first proposed by Kreshuk et al ., who use a Random Forest (RF) classifier on hand-selected image features to detect synapses [7].”
BackgroundMethodInfluentialWho Is Talking to Whom: Synaptic Partner Detection in Anisotropic Volumes of Insect Brain
Kreshuk, A., Funke, J., Cardona, A., & Hamprecht, F. A. (2015) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-24553-9_81 · Cited by 19
Self-citationSynaptic Partner Prediction from Point Annotations in Insect Brains
Buhmann, J., Krause, R., Lentini, R. C., Eckstein, N., Cook, M., Turaga, S., & Funke, J. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-00934-2_35 · Cited by 15
Metadata
- Authors
- Kreshuk, A., Straehle, C. N., Sommer, C., Koethe, U., Cantoni, M., Knott, G., & Hamprecht, F. A.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2011-10-21
- Volume
- 6
- Issue
- 10
- Pages
- e24899
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2072350275
- Cited by
- 140
- References
- 6
- FWCI
- 7.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.