CoChat

Quantification Bias Caused by Plasmid DNA Conformation in Quantitative Real-Time PCR Assay

Open access

The DOI matches its Crossref record; 23 of the 24 references it cites were found in a registry or an index.

Abstract

Quantitative real-time PCR (qPCR) is the gold standard for the quantification of specific nucleic acid sequences. However, a serious concern has been revealed in a recent report: supercoiled plasmid standards cause significant over-estimation in qPCR quantification. In this study, we investigated the effect of plasmid DNA conformation on the quantification of DNA and the efficiency of qPCR. Our results suggest that plasmid DNA conformation has significant impact on the accuracy of absolute quantification by qPCR. DNA standard curves shifted significantly among plasmid standards with different DNA conformations. Moreover, the choice of DNA measurement method and plasmid DNA conformation may also contribute to the measurement error of DNA standard curves. Due to the multiple effects of plasmid DNA conformation on the accuracy of qPCR, efforts should be made to assure the highest consistency of plasmid standards for qPCR. Thus, we suggest that the conformation, preparation, quantification, purification, handling, and storage of standard plasmid DNA should be described and defined in the Minimum Information for Publication of Quantitative Real-Time PCR Experiments (MIQE) to assure the reproducibility and accuracy of qPCR absolute quantification.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0029101

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Preparation of plasmid samples. Lane M: 1 kb ladder DNA marker. Lane 1: S, supercoiled plasmid sample. Lane 2: L, linear plasmid sample (SspI treated). Lane 3: N, nicked-circular plasmid sample (Nt.BspQI treated). Lane 4: C, closed-circular plasmid sample (topoisomerase I treated). Lane 5: S-LB, supercoiled plasmid treated with SspI reaction buffer. Lane 6: S-NB, supercoiled plasmid treated with Nt.BspQI reaction buffer. Lane 7: S-CB, supercoiled plasmid treated with topoisomerase I reaction buffer.
Figure 1 Preparation of plasmid samples. Lane M: 1 kb ladder DNA marker. Lane 1: S, supercoiled plasmid sample. Lane 2: L, linear plasmid sample (SspI treated). Lane 3: N, nicked-circular plasmid sample (Nt.BspQI treated). Lane 4: C, closed-circular plasmid sample (topoisomerase I treated). Lane 5: S-LB, supercoiled plasmid treated with SspI reaction buffer. Lane 6: S-NB, supercoiled plasmid treated with Nt.BspQI reaction buffer. Lane 7: S-CB, supercoiled plasmid treated with topoisomerase I reaction buffer.CC BY · PubMed Central
Figure 2 Effect of plasmid DNA conformation on DNA measurement methods. (A) Comparison of various methods on supercoiled plasmid DNA quantification. (B) Hoechst dye-based DNA quantification method. (C) Quant-iT dsDNA BR quantification assay. (D) OD260 DNA quantification method. S-LB: supercoiled plasmid treated with SspI reaction buffer. S-NB: supercoiled plasmid treated with Nt.BspQI reaction buffer. S-CB: supercoiled plasmid treated with topoisomerase I reaction buffer. a, b, c, d and e : groups with significant difference to each other (Duncan's multiple range test, P<0.05).
Figure 2 Effect of plasmid DNA conformation on DNA measurement methods. (A) Comparison of various methods on supercoiled plasmid DNA quantification. (B) Hoechst dye-based DNA quantification method. (C) Quant-iT dsDNA BR quantification assay. (D) OD260 DNA quantification method. S-LB: supercoiled plasmid treated with SspI reaction buffer. S-NB: supercoiled plasmid treated with Nt.BspQI reaction buffer. S-CB: supercoiled plasmid treated with topoisomerase I reaction buffer. a, b, c, d and e : groups with significant difference to each other (Duncan's multiple range test, P<0.05).CC BY · PubMed Central
Figure 3 Effect of plasmid DNA conformation on qPCR calibration curves. Each data point was the average of three triplicate tests (n = 9). Blue lines: Supercoiled plasmid calibration curves. Red lines: Linear plasmid calibration curves. Gold lines: Nicked-circular plasmid calibration curves. Magenta lines: close-circular calibration curves. Grey lines: Buffer control (S-LB, S-NB and S-CB, supercoiled) plasmid calibration curves.
Figure 3 Effect of plasmid DNA conformation on qPCR calibration curves. Each data point was the average of three triplicate tests (n = 9). Blue lines: Supercoiled plasmid calibration curves. Red lines: Linear plasmid calibration curves. Gold lines: Nicked-circular plasmid calibration curves. Magenta lines: close-circular calibration curves. Grey lines: Buffer control (S-LB, S-NB and S-CB, supercoiled) plasmid calibration curves.CC BY · PubMed Central
Figure 4 Effect of plasmid DNA conformation on qPCR chemistries. Relative amplification was calculated by the ΔCt value to the corresponding supercoiled plasmid group. Each data point was the average of three triplicate tests (n = 9) with 200 copies of plasmid DNA sample. * : P<0.05. *** : P<0.001.
Figure 4 Effect of plasmid DNA conformation on qPCR chemistries. Relative amplification was calculated by the ΔCt value to the corresponding supercoiled plasmid group. Each data point was the average of three triplicate tests (n = 9) with 200 copies of plasmid DNA sample. * : P<0.05. *** : P<0.001.CC BY · PubMed Central
Figure 5 Three hypothetical type of DNA amplification in qPCR. Type I: The amplification from DNA template (plasmid). Type II : The amplification from PCR product of type I. Type III : The amplification of PCR product itself.
Figure 5 Three hypothetical type of DNA amplification in qPCR. Type I: The amplification from DNA template (plasmid). Type II : The amplification from PCR product of type I. Type III : The amplification of PCR product itself.CC BY · PubMed Central
Figure 6 The proposed and virtual effect of initial PCR efficiency (Ei) on qPCR amplification curves (assuming Eii = Eiii). Ei (initial PCR efficiency): the efficiency of type I amplification. Eii: the efficiency of type II amplification. Eiii: the efficiency of type III amplification. (A) Proposed amplification curves with 100% (theoretical), 10% and 1% Ei. (B) Proposed amplification curves of 100% and 20% Ei with 10 and 100 copies of DNA template (initial copy number, Ci). (C) Proposed amplification curves of 100% and 20% Ei with 10 and 100 Ci in PCR. Difference in Ei will consistently shift Ct value (by the change of Y-intercept). (D) PCR amplification curves of supercoiled and nicked-circular plasmid DNA with 2,000 and 20,000 Ci in this study.
Figure 6 The proposed and virtual effect of initial PCR efficiency (Ei) on qPCR amplification curves (assuming Eii = Eiii). Ei (initial PCR efficiency): the efficiency of type I amplification. Eii: the efficiency of type II amplification. Eiii: the efficiency of type III amplification. (A) Proposed amplification curves with 100% (theoretical), 10% and 1% Ei. (B) Proposed amplification curves of 100% and 20% Ei with 10 and 100 copies of DNA template (initial copy number, Ci). (C) Proposed amplification curves of 100% and 20% Ei with 10 and 100 Ci in PCR. Difference in Ei will consistently shift Ct value (by the change of Y-intercept). (D) PCR amplification curves of supercoiled and nicked-circular plasmid DNA with 2,000 and 20,000 Ci in this study.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Research works printed but not linked: 1

  1. 2003, Regulation (EC) No. 1829/2003 and 1830/2003., Off J Eur Union, L268, 1

Cited by

See all 86

Metadata

Authors
Lin, C.-H., Chen, Y.-C., & Pan, T.-M.
Affiliations
National Taiwan University (TW)
Corresponding author
Pan, Tzu-Ming
Venue
PLoS ONE
Published
2011-12-14
Volume
6
Issue
12
Pages
e29101
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2073174343
Cited by
82
References
24
Citations by year
2026: 4 · 2025: 4 · 2024: 6 · 2023: 8 · 2022: 6 · 2021: 10 · 2020: 11 · 2019: 3 · 2018: 1 · 2017: 4 · 2016: 8 · 2015: 5 · 2014: 4 · 2013: 6 · 2012: 2
FWCI
1.56
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › DNA and Nucleic Acid Chemistry
  • Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
Keywords
supercoiled plasmid DNA, absolute quantification, calibration curve, measurement error, plasmid DNA preparation, MIQE guidelines, reproducibility
MeSH terms
Biological Assay, Calibration, Zea mays, Diamines, DNA, DNA, Superhelical, Nucleic Acid Conformation, Organic Chemicals, Plasmids, Quinolines, Bias, Plants, Genetically Modified, Benzothiazoles, Real-Time Polymerase Chain Reaction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantification Bias Caused by Plasmid DNA Conformation in Quantitative Real-Time PCR Assay. https://app.cochat.ai/papers/10.1371/journal.pone.0029101
The paper
Lin, C.-H., Chen, Y.-C., & Pan, T.-M. (2011). Quantification Bias Caused by Plasmid DNA Conformation in Quantitative Real-Time PCR Assay. PLoS ONE. https://doi.org/10.1371/journal.pone.0029101

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.