The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Raman Spectroscopy Provides a Powerful Diagnostic Tool for Accurate Determination of Albumin Glycation
Open accessAbstract
We present the first demonstration of glycated albumin detection and quantification using Raman spectroscopy without the addition of reagents. Glycated albumin is an important marker for monitoring the long-term glycemic history of diabetics, especially as its concentrations, in contrast to glycated hemoglobin levels, are unaffected by changes in erythrocyte life times. Clinically, glycated albumin concentrations show a strong correlation with the development of serious diabetes complications including nephropathy and retinopathy. In this article, we propose and evaluate the efficacy of Raman spectroscopy for determination of this important analyte. By utilizing the pre-concentration obtained through drop-coating deposition, we show that glycation of albumin leads to subtle, but consistent, changes in vibrational features, which with the help of multivariate classification techniques can be used to discriminate glycated albumin from the unglycated variant with 100% accuracy. Moreover, we demonstrate that the calibration model developed on the glycated albumin spectral dataset shows high predictive power, even at substantially lower concentrations than those typically encountered in clinical practice. In fact, the limit of detection for glycated albumin measurements is calculated to be approximately four times lower than its minimum physiological concentration. Importantly, in relation to the existing detection methods for glycated albumin, the proposed method is also completely reagent-free, requires barely any sample preparation and has the potential for simultaneous determination of glycated hemoglobin levels as well. Given these key advantages, we believe that the proposed approach can provide a uniquely powerful tool for quantification of glycation status of proteins in biopharmaceutical development as well as for glycemic marker determination in routine clinical diagnostics in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Diabetes Care · doi:10.2337/dc11-9998 · Cited by 718
Toward a Glucose Biosensor Based on Surface-Enhanced Raman Scattering
Shafer-Peltier, K. E., Haynes, C. L., Glucksberg, M. R., & Van Duyne, R. P. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028255v · Cited by 653
The glycation of albumin: Structural and functional impacts
Rondeau, P., & Bourdon, E. (2011) · Biochimie · doi:10.1016/j.biochi.2010.12.003 · Cited by 433
A new look at screening and diagnosing diabetes mellitus
Saudek, C. D., Herman, W. H., Sacks, D. B., Bergenstal, R. M., Edelman, D., & Davidson, M. B. (2008) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2007-2174 · Cited by 432
Comparison of glycated albumin and hemoglobin A1c levels in diabetic subjects on hemodialysis
Peacock, T. P., Shihabi, Z. K., Bleyer, A. J., Dolbare, E. L., Byers, J. R., Knovich, M. A., Calles-Escandon, J., Russell, G. B., & Freedman, B. I. (2008) · Kidney International · doi:10.1038/ki.2008.25 · Cited by 323
Freedman, B. I., Shenoy, R. N., Planer, J. A., Clay, K. D., Shihabi, Z. K., Burkart, J. M., Cardona, C. Y., Andries, L., Peacock, T. P., Sabio, H., et al. (2010) · Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis · doi:10.3747/pdi.2008.00243 · Cited by 121
Cited by
Review: Glycation of human serum albumin
Anguizola, J., Matsuda, R., Barnaby, O. S., Hoy, K. S., Wa, C., DeBolt, E., Koke, M., & Hage, D. S. (2013) · Clinica Chimica Acta · doi:10.1016/j.cca.2013.07.013 · Cited by 395
Surface-enhanced Raman spectroscopy for bioanalysis and diagnosis
Tahir, M. A., Dina, N. E., Cheng, H., Valev, V. K., & Zhang, L. (2021) · Nanoscale · doi:10.1039/d1nr00708d · Cited by 257
In Vitro and In Vivo SERS Biosensing for Disease Diagnosis
Moore, T. J., Moody, A. S., Payne, T. D., Sarabia, G. M., Daniel, A. R., & Sharma, B. (2018) · Biosensors · doi:10.3390/bios8020046 · Cited by 161
Quantification of protein glycation using vibrational spectroscopy
McAvan, B. S., France, A. P., Bellina, B., Barran, P. E., Goodacre, R., & Doig, A. J. (2020) · The Analyst · doi:10.1039/c9an02318f · Cited by 35
Metadata
- Authors
- Dingari, N. C., Horowitz, G. L., Kang, J. W., Dasari, R. R., & Barman, I.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2012-02-29
- Volume
- 7
- Issue
- 2
- Pages
- e32406
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2024895662
- Cited by
- 168
- References
- 6
- FWCI
- 6.75
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Raman Spectroscopy Provides a Powerful Diagnostic Tool for Accurate Determination of Albumin Glycation. https://app.cochat.ai/papers/10.1371/journal.pone.0032406
- The paper
- Dingari, N. C., Horowitz, G. L., Kang, J. W., Dasari, R. R., & Barman, I. (2012). Raman Spectroscopy Provides a Powerful Diagnostic Tool for Accurate Determination of Albumin Glycation. PLoS ONE. https://doi.org/10.1371/journal.pone.0032406
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.