The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Highly Precise Measurement of HIV DNA by Droplet Digital PCR
Open accessAbstract
Deoxyribonucleic acid (DNA) of the human immunodeficiency virus (HIV) provides the most sensitive measurement of residual infection in patients on effective combination antiretroviral therapy (cART). Droplet digital PCR (ddPCR) has recently been shown to provide highly accurate quantification of DNA copy number, but its application to quantification of HIV DNA, or other equally rare targets, has not been reported. This paper demonstrates and analyzes the application of ddPCR to measure the frequency of total HIV DNA (pol copies per million cells), and episomal 2-LTR (long terminal repeat) circles in cells isolated from infected patients. Analysis of over 300 clinical samples, including over 150 clinical samples assayed in triplicate by ddPCR and by real-time PCR (qPCR), demonstrates a significant increase in precision, with an average 5-fold decrease in the coefficient of variation of pol copy numbers and a >20-fold accuracy improvement for 2-LTR circles. Additional benefits of the ddPCR assay over qPCR include absolute quantification without reliance on an external standard and relative insensitivity to mismatches in primer and probe sequences. These features make digital PCR an attractive alternative for measurement of HIV DNA in clinical specimens. The improved sensitivity and precision of measurement of these rare events should facilitate measurements to characterize the latent HIV reservoir and interventions to eradicate it.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid turnover of plasma virions and CD4 lymphocytes in HIV-1 infection
Ho, D. D., Neumann, A. U., Perelson, A. S., Chen, W., Leonard, J. M., & Markowitz, M. (1995) · Nature · doi:10.1038/373123a0 · Cited by 4,267
High-throughput droplet digital PCR system for absolute quantitation of DNA copy number
Hindson, B. J., Ness, K. D., Masquelier, D. A., Belgrader, P., Heredia, N. J., Makarewicz, A. J., Bright, I. J., Lucero, M. Y., Hiddessen, A. L., Legler, T. C., et al. (2011) · Analytical Chemistry · doi:10.1021/ac202028g · Cited by 2,792 · cited 4×
“Because the system works by counting positive reactions among approximately 15,000 droplets per sample well, the dynamic range is limited to between 4 and 5 log10 [8].”
BackgroundResultInfluentialKinetic PCR Analysis: Real-time Monitoring of DNA Amplification Reactions
Higuchi, R., Fockler, C., Dollinger, G., & Watson, R. (1993) · Nature Biotechnology · doi:10.1038/nbt0993-1026 · Cited by 2,159
Vogelstein, B., & Kinzler, K. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9236 · Cited by 1,770 · cited 1×
“Digital PCR (dPCR) [2], in which the amplification reaction is divided into thousands of microscopic reaction volumes, is a rapidly growing alternative that is potentially more accurate [3,4,5] and more precise [6,7].”
BackgroundHigh Levels of HIV-1 in Plasma During All Stages of Infection Determined By Competitive PCR
Piatak, M., Saag, M. S., Yang, L. C., Clark, S. J., Kappes, J. C., Luk, K.-C., Hahn, B. H., Shaw, G. M., & Lifson, J. D. (1993) · Science · doi:10.1126/science.8096089 · Cited by 1,237
A quantitative assay for HIV DNA integration in vivo
Butler, S. L., Hansen, M. S. T., & Bushman, F. D. (2001) · Nature Medicine · doi:10.1038/87979 · Cited by 687
Whale, A. S., Huggett, J. F., Cowen, S., Speirs, V., Shaw, J., Ellison, S., Foy, C. A., & Scott, D. J. (2012) · Nucleic Acids Research · doi:10.1093/nar/gks203 · Cited by 453 · cited 1×
“Digital PCR (dPCR) [2], in which the amplification reaction is divided into thousands of microscopic reaction volumes, is a rapidly growing alternative that is potentially more accurate [3,4,5] and more precise [6,7].”
BackgroundMicrofluidics Digital PCR Reveals a Higher than Expected Fraction of Fetal DNA in Maternal Plasma
Lun, F. M. F., Chiu, R. W. K., Allen Chan, K. C., Yeung Leung, T., Kin Lau, T., & Dennis Lo, Y. M. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2008.111385 · Cited by 433
Yung, T. K. F., Chan, K. C. A., Mok, T. S. K., Tong, J., To, K.-F., & Lo, Y. M. D. (2009) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-08-2622 · Cited by 385
Evaluation of digital PCR for absolute DNA quantification
Sanders, R., Huggett, J. F., Bushell, C. A., Cowen, S., Scott, D. J., & Foy, C. A. (2011) · Analytical Chemistry · doi:10.1021/ac103230c · Cited by 338
Strain, M. C., Günthard, H. F., Havlir, D. V., Ignacio, C. C., Smith, D. M., Leigh-Brown, A. J., Macaranas, T. R., Lam, R. Y., Daly, O. A., Fischer, M., et al. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0736332100 · Cited by 254
Self-citationProbing Individual Environmental Bacteria for Viruses by Using Microfluidic Digital PCR
Tadmor, A. D., Ottesen, E. A., Leadbetter, J. R., & Phillips, R. (2011) · Science · doi:10.1126/science.1200758 · Cited by 230
Principle and applications of digital PCR
Pohl, G., & Shih, I.-M. (2004) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.4.1.41 · Cited by 206
Digital PCR provides sensitive and absolute calibration for high throughput sequencing
White, R. A., Blainey, P. C., Fan, H. C., & Quake, S. R. (2009) · BMC Genomics · doi:10.1186/1471-2164-10-116 · Cited by 195
Kreutz, J. E., Munson, T., Huynh, T., Shen, F., Du, W., & Ismagilov, R. F. (2011) · Analytical Chemistry · doi:10.1021/ac201658s · Cited by 148
Microfluidic digital PCR enables rapid prenatal diagnosis of fetal aneuploidy
Fan, H. C., Blumenfeld, Y. J., El-Sayed, Y. Y., Chueh, J. T., & Quake, S. R. (2009) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2009.03.002 · Cited by 111
Partly Nonparametric Approach for Determining the Limit of Detection
Línnet, K., & Kondratovich, M. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.029983 · Cited by 107
Digital PCR provides absolute quantitation of viral load for an occult RNA virus
White, R. A., III, Quake, S. R., & Curr, K. A. (2011) · Journal of Virological Methods · doi:10.1016/j.jviromet.2011.09.017 · Cited by 99
The cellular factor TRP‐185 regulates RNA polymerase II binding to HIV‐1 TAR RNA.
Wu-Baer, F., Lane, W. S., & Gaynor, R. B. (1995) · The EMBO Journal · doi:10.1002/j.1460-2075.1995.tb00288.x · Cited by 42
Everall, I., Hudson, L., Al‐Sarraj, S., Honavar, M., Lantos, P. L., & Kerwin, R. W. (1995) · Nature Medicine · doi:10.1038/nm1195-1174 · Cited by 38
Cited by
Defective proviruses rapidly accumulate during acute HIV-1 infection
Bruner, K. M., Murray, A. J., Pollack, R. A., Soliman, M. G., Laskey, S. B., Capoferri, A. A., Lai, J., Strain, M. C., Lada, S. M., Hoh, R., et al. (2016) · Nature Medicine · doi:10.1038/nm.4156 · Cited by 737
Self-citationRapid pathogen detection by metagenomic next-generation sequencing of infected body fluids
Gu, W., Deng, X., Lee, M., Sucu, Y. D., Arevalo, S., Stryke, D., Federman, S., Gopez, A., Reyes, K., Zorn, K., et al. (2021) · Nature Medicine · doi:10.1038/s41591-020-1105-z · Cited by 689
Quan, P.-L., Sauzade, M., & Brouzes, E. (2018) · Sensors · doi:10.3390/s18041271 · Cited by 664
Absence of Detectable HIV-1 Viremia after Treatment Cessation in an Infant
Persaud, D., Gay, H., Ziemniak, C., Chen, Y. H., Piatak, M., Chun, T.-W., Strain, M., Richman, D., & Luzuriaga, K. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1302976 · Cited by 581
Self-citationComparative Analysis of Measures of Viral Reservoirs in HIV-1 Eradication Studies
Eriksson, S., Graf, E. H., Dahl, V., Strain, M. C., Yukl, S. A., Lysenko, E. S., Bosch, R. J., Lai, J., Chioma, S., Emad, F., et al. (2013) · PLoS Pathogens · doi:10.1371/journal.ppat.1003174 · Cited by 567
Self-citation
Metadata
- Authors
- Strain, M. C., Lada, S. M., Luong, T., Rought, S. E., Gianella, S., Terry, V. H., Spina, C. A., Woelk, C. H., & Richman, D. D.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2013-04-03
- Volume
- 8
- Issue
- 4
- Pages
- e55943
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2128446740
- Cited by
- 504
- References
- 20
- FWCI
- 21.83
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.