Model Free Approach to Kinetic Analysis of Real-Time Hyperpolarized 13C Magnetic Resonance Spectroscopy Data
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Real-time detection of the rates of metabolic flux, or exchange rates of endogenous enzymatic reactions, is now feasible in biological systems using Dynamic Nuclear Polarization Magnetic Resonance. Derivation of reaction rate kinetics from this technique typically requires multi-compartmental modeling of dynamic data, and results are therefore model-dependent and prone to misinterpretation. We present a model-free formulism based on the ratio of total areas under the curve (AUC) of the injected and product metabolite, for example pyruvate and lactate. A theoretical framework to support this novel analysis approach is described, and demonstrates that the AUC ratio is proportional to the forward rate constant k. We show that the model-free approach strongly correlates with k for whole cell in vitro experiments across a range of cancer cell lines, and detects response in cells treated with the pan-class I PI3K inhibitor GDC-0941 with comparable or greater sensitivity. The same result is seen in vivo with tumor xenograft-bearing mice, in control tumors and following drug treatment with dichloroacetate. An important finding is that the area under the curve is independent of both the input function and of any other metabolic pathways arising from the injected metabolite. This model-free approach provides a robust and clinically relevant alternative to kinetic model-based rate measurements in the clinical translation of hyperpolarized (13)C metabolic imaging in humans, where measurement of the input function can be problematic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Understanding the Warburg Effect: The Metabolic Requirements of Cell Proliferation
Vander Heiden, M. G., Cantley, L. C., & Thompson, C. B. (2009) · Science · doi:10.1126/science.1160809 · Cited by 16,197 · cited 1×
“energy metabolism evident in cancer, known as the Warburg effect [7].”
BackgroundIncrease in signal-to-noise ratio of > 10,000 times in liquid-state NMR
Ardenkjær-Larsen, J. H., Fridlund, B., Gram, A., Hansson, G., Hansson, L., Lerche, M. H., Servin, R., Thaning, M., & Golman, K. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1733835100 · Cited by 2,861 · cited 1×
“Dynamic Nuclear Polarization (DNP) provides a factor of 10(4)–10(5) MRS signal enhancement [6], which allows for real-time metabolic imaging of enzyme kinetics in biological systems using (13)C MRS.”
Reaction Rates by Nuclear Magnetic Resonance
McConnell, H. M. (1958) · The Journal of Chemical Physics · doi:10.1063/1.1744152 · Cited by 1,624 · cited 2×
“These apparent reaction rate constants are typically determined by kinetic modeling of the dynamic data using the McConnell equations (modified Bloch equations) [11].”
MethodBonnet, S., Archer, S. L., Allalunis-Turner, J., Haromy, A., Beaulieu, C., Thompson, R., Lee, C. T., Lopaschuk, G. D., Puttagunta, L., Bonnet, S., et al. (2007) · Cancer Cell · doi:10.1016/j.ccr.2006.10.020 · Cited by 1,530 · cited 1×
“DCA has been shown to induce apoptosis, decrease proliferation and inhibit tumor growth, without apparent toxicity [17].”
BackgroundGuidelines for the welfare and use of animals in cancer research
An ad hoc committee of the National Cancer Research Institute, Workman, P., Aboagye, E. O., Balkwill, F., Balmain, A., Bruder, G., Chaplin, D. J., Double, J. A., Everitt, J., Farningham, D. A. H., et al. (2010) · British Journal of Cancer · doi:10.1038/sj.bjc.6605642 · Cited by 1,442 · cited 1×
“All procedures performed on mice were approved by the Institute of Cancer Research Ethical Review Committee and with the authority of Personal and Project Licences issued by the UK Home Office under the Animals (Scientific Procedures) Act 1986, and in accordance with the United Kingdom National Cancer Research Institu…”
MethodDay, S. E., Kettunen, M. I., Gallagher, F. A., Hu, D.-E., Lerche, M., Wolber, J., Golman, K., Ardenkjaer-Larsen, J. H., & Brindle, K. M. (2007) · Nature Medicine · doi:10.1038/nm1650 · Cited by 883 · cited 3×
“In vivo kPL values are consistent with those previously reported for various preclinical cancer models [9,12,14,27,28].”
BackgroundMethodResultRole of BAX in the Apoptotic Response to Anticancer Agents
Zhang, L., Yu, J., Park, B. H., Kinzler, K. W., & Vogelstein, B. (2000) · Science · doi:10.1126/science.290.5493.989 · Cited by 863 · cited 1×
“Paul Clarke, ICR, Sutton, UK [21], cultured in DMEM with glutamine and 1% non-essential amino acids (Invitrogen, UK)), HT29 colon carcinoma (from American Type Culture Collection, ATCC, cultured in McCoy 5A Medium with glutamine and HEPES (Invitrogen, UK)), PC3 prostate adenocarcinoma (from American Type Culture Colle…”
BackgroundHowe, F. A., Barton, S. J., Cudlip, S. A., Stubbs, M., Saunders, D. E., Murphy, M., Wilkins, P., Opstad, K. S., Doyle, V. L., McLean, M. A., et al. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10367 · Cited by 539 · cited 1×
“Compared with other imaging modalities, such as positron emission tomography (PET) or single photon emission computed tomography (SPECT), MRS has lower sensitivity, but its chemical specificity enables clinical identification of tumor types [1], steady state metabolomic investigations of health and disease [2] as well…”
BackgroundAlbers, M. J., Bok, R., Chen, A. P., Cunningham, C. H., Zierhut, M. L., Zhang, V. Y., Kohler, S. J., Tropp, J., Hurd, R. E., Yen, Y.-F., et al. (2008) · Cancer Research · doi:10.1158/0008-5472.can-08-0749 · Cited by 520 · cited 1×
“(demonstrated by the formation of [1-(13)C]bicarbonate, which is in equilibrium with carbon dioxide, under the action of the enzyme carbonic anhydrase (CA)), or converted to [1-(13)C]alanine in the cytosol by alanine transaminase (ALT) [10].”
BackgroundPattern recognition methods and applications in biomedical magnetic resonance
Lindon, J. C., Holmes, E., & Nicholson, J. K. (2001) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/s0079-6565(00)00036-4 · Cited by 425 · cited 1×
“Compared with other imaging modalities, such as positron emission tomography (PET) or single photon emission computed tomography (SPECT), MRS has lower sensitivity, but its chemical specificity enables clinical identification of tumor types [1], steady state metabolomic investigations of health and disease [2] as well…”
BackgroundMagnetic Resonance Spectroscopy
Gujar, S. K., Maheshwari, S., Bj??rkman-Burtscher, I., & Sundgren, P. C. (2005) · Journal of Neuro-Ophthalmology · doi:10.1097/01.wno.0000177307.21081.81 · Cited by 380
NMR-Based Metabolic Profiling and Metabonomic Approaches to Problems in Molecular Toxicology
Coen, M., Holmes, E., Lindon, J. C., & Nicholson, J. K. (2008) · Chemical Research in Toxicology · doi:10.1021/tx700335d · Cited by 304
Harris, T., Eliyahu, G., Frydman, L., & Degani, H. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0909049106 · Cited by 226 · cited 1×
“Furthermore, characteristics of pyruvate and lactate transport by MCT1 and MCT4 have been investigated using cell perfusion systems and hyperpolarized pyruvate [24,31].”
MethodMorris, M. E., & Felmlee, M. A. (2008) · The AAPS Journal · doi:10.1208/s12248-008-9035-6 · Cited by 192 · cited 1×
“This assumption is based on the relative affinities of the transporters for pyruvate and lactate respectively [20].”
BackgroundKinetic modeling of hyperpolarized 13C1-pyruvate metabolism in normal rats and TRAMP mice
Zierhut, M. L., Yen, Y.-F., Chen, A. P., Bok, R., Albers, M. J., Zhang, V., Tropp, J., Park, I., Vigneron, D. B., Kurhanewicz, J., et al. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2009.10.003 · Cited by 166 · cited 3×
“In vivo kPL values are consistent with those previously reported for various preclinical cancer models [9,12,14,27,28].”
MethodResultWard, C. S., Venkatesh, H. S., Chaumeil, M. M., Brandes, A., Criekinge, M. V., Dafni, H., Sukumar, S., Nelson, S. J., Vigneron, D. B., Kurhanewicz, J. V., et al. (2010) · Cancer Research · doi:10.1158/0008-5472.can-09-2251 · Cited by 155 · cited 2×
“The AUC ratio method detected response to GDC-0941 treatment with slightly greater significance than 2-site and 3-site kinetic models, and this reduction in AUC ratio and kPL is consistent with previous work relating to PI3K inhibition in cancer [8].”
BackgroundResultKinetic Modeling of Hyperpolarized 13C Label Exchange between Pyruvate and Lactate in Tumor Cells
Witney, T. H., Kettunen, M. I., & Brindle, K. M. (2011) · Journal of Biological Chemistry · doi:10.1074/jbc.m111.237727 · Cited by 152
Imaging of blood flow using hyperpolarized [13C]Urea in preclinical cancer models
von Morze, C., Larson, P. E. Z., Hu, S., Keshari, K. R., Wilson, D. M., Ardenkjær‐Larsen, J. H., Goga, A., Bok, R., Kurhanewicz, J. V., & Vigneron, D. B. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22484 · Cited by 127 · cited 1×
“urea) [13] and signal localization on a suitable vessel [12], but these methods involve more complex experimental or acquisition designs that will, in practice, decrease the overall robustness of the technique.”
MethodComparison of kinetic models for analysis of pyruvate‐to‐lactate exchange by hyperpolarized 13C NMR
Harrison, C., Yang, C., Jindal, A., DeBerardinis, R. J., Hooshyar, M. A., Merritt, M., Dean Sherry, A., & Malloy, C. R. (2012) · NMR in Biomedicine · doi:10.1002/nbm.2801 · Cited by 112 · cited 3×
“In the 3site model, intracellular and extracellular lactate effective relaxation rates were assumed to be the same [19].”
BackgroundMethodResultHaas-Kogan, D. A., Yount, G. L., Haas, M., Levi, D., Kogan, S. C., Hu, L. J., Vidair, C. A., Deen, D. F., Dewey, W. C., & Israel, M. A. (1996) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(96)00244-1 · Cited by 112 · cited 1×
“Daphne HaasKogan, UCSF, San Francisco, CA, USA [22], cultured in DMEM/F12 Ham’s medium (Invitrogen, UK), without penicillin & streptomycin), SW1222 colon carcinoma (from The European Collection of Cell Cultures, ECACC, cultured in DMEM with glutamine (Invitrogen, UK)), WM266-4 melanoma (from American Type Culture Coll…”
MethodKeshari, K. R., Sriram, R., Koelsch, B. L., Criekinge, M. V., Wilson, D. M., Kurhanewicz, J. V., & Wang, Z. J. (2013) · Cancer Research · doi:10.1158/0008-5472.can-12-3461 · Cited by 104 · cited 1×
“Furthermore, characteristics of pyruvate and lactate transport by MCT1 and MCT4 have been investigated using cell perfusion systems and hyperpolarized pyruvate [24,31].”
MethodKeshari, K. R., Kurhanewicz, J. V., Jeffries, R. E., Wilson, D. M., Dewar, B. J., Criekinge, M. V., Zierhut, M. L., Vigneron, D. B., & Macdonald, J. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22225 · Cited by 86
On-target Inhibition of Tumor Fermentative Glycolysis as Visualized by Hyperpolarized Pyruvate
Seth, P., Grant, A., Tang, J., Vinogradov, E., Wang, X., Lenkinski, R., & Sukhatme, V. P. (2011) · Neoplasia · doi:10.1593/neo.101020 · Cited by 81
Functional imaging in adult and paediatric brain tumours
Peet, A. C., Arvanitis, T. N., Leach, M. O., & Waldman, A. D. (2012) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2012.187 · Cited by 74
Self-citationSpielman, D. M., Mayer, D., Yen, Y., Tropp, J. S., Hurd, R. E., & Pfefferbaum, A. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21998 · Cited by 69 · cited 1×
“The most commonly used models in the literature are 2-site exchange [9,14,18] and 3-site exchange [19], which are based on the modified Bloch equations [11].”
MethodKazan, S. M., Reynolds, S., Kennerley, A. J., Wholey, E. G., Bluff, J. E., Berwick, J., Cunningham, V. J., Paley, M. N. J., & Tozer, G. M. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24546 · Cited by 61 · cited 3×
“In vivo kPL values are consistent with those previously reported for various preclinical cancer models [9,12,14,27,28].”
BackgroundMethodResultKettunen, M. I., Kennedy, B. W. C., Hu, D., & Brindle, K. M. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24591 · Cited by 52
Menichetti, L., Frijia, F., Flori, A., Wiesinger, F., Lionetti, V., Giovannetti, G., Aquaro, G. D., Recchia, F. A., Ardenkjær‐Larsen, J. H., Santarelli, M. F., et al. (2012) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.480 · Cited by 52 · cited 1×
“This approach removes the influence of the AIF [16].”
BackgroundPark, J. M., Josan, S., Jang, T., Merchant, M. J., Yen, Y., Hurd, R. E., Recht, L. D., Spielman, D. M., & Mayer, D. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24181 · Cited by 47
Diffusion MR of hyperpolarized 13C molecules in solution
Koelsch, B. L., Keshari, K. R., Peeters, T. H., Larson, P. E. Z., Wilson, D. M., & Kurhanewicz, J. V. (2013) · The Analyst · doi:10.1039/c2an36715g · Cited by 40
Beloueche‐Babari, M., Workman, P., & Leach, M. O. (2011) · Cell Cycle · doi:10.4161/cc.10.17.17192 · Cited by 22
Self-citationLarson, P. E. Z., Kerr, A. B., Swisher, C. L., Pauly, J. M., & Vigneron, D. B. (2012) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.09.014 · Cited by 21 · cited 1×
“In vivo kPL values are consistent with those previously reported for various preclinical cancer models [9,12,14,27,28].”
Result
Cited by
Rajeshkumar, N. V., Dutta, P., Yabuuchi, S., de Wilde, R. F., Martinez, G. V., Le, A., Kamphorst, J. J., Rabinowitz, J. D., Jain, S. K., Hidalgo, M., et al. (2015) · Cancer Research · doi:10.1158/0008-5472.can-15-0108 · Cited by 158
“The Lac/Pyr flux ratio was calculated from the area under the curve (as regarded a “Model-Free” approach) of the metabolic flux from the dynamic scan (30).”
Imaging of glucose metabolism by 13C-MRI distinguishes pancreatic cancer subtypes in mice
Kishimoto, S., Brender, J. R., Crooks, D. R., Matsumoto, S., Seki, T., Oshima, N., Merkle, H., Lin, P., Reed, G., Chen, A. P., et al. (2019) · eLife · doi:10.7554/elife.46312 · Cited by 41
“…in the time-averaged glucose to lactate ratio (Figure 3F, Mann-Whitney rank test, p=0.03, Cohen’s d = 1.20, large effect size), which is an approximate measure of the relative rates of the appearance of lactate and disappearance of glucose within the FOV of the scanner (Hill et al., 2013).”
InfluentialYamamoto, K., Brender, J. R., Seki, T., Kishimoto, S., Oshima, N., Choudhuri, R., Adler, S. S., Jagoda, E. M., Saito, K., Devasahayam, N., et al. (2020) · Cancer Research · doi:10.1158/0008-5472.can-19-0928 · Cited by 37
“Using the lactate/pyruvate ratios reduces this dependence, for in simplifiedmodels withfirst order kinetics, the ratio is strictly equal to the rate of the conversion of pyruvate to lactate (16).”
BackgroundWeighted averaging in spectroscopic studies improves statistical power
Miller, J. J., Cochlin, L., Clarke, K., & Tyler, D. J. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26615 · Cited by 16
Metadata
- Authors
- Hill, D. K., Orton, M. R., Mariotti, E., Boult, J. K. R., Panek, R., Jafar, M., Parkes, H. G., Jamin, Y., Miniotis, M. F., Al-Saffar, N. M. S., Beloueche-Babari, M., Robinson, S. P., Leach, M. O., Chung, Y.-L., & Eykyn, T. R.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2013-09-04
- Volume
- 8
- Issue
- 9
- Pages
- e71996
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W1966092661
- Cited by
- 164
- References
- 32
- FWCI
- 6.14
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.