Systolic Peak Detection in Acceleration Photoplethysmograms Measured from Emergency Responders in Tropical Conditions
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Photoplethysmogram (PPG) monitoring is not only essential for critically ill patients in hospitals or at home, but also for those undergoing exercise testing. However, processing PPG signals measured after exercise is challenging, especially if the environment is hot and humid. In this paper, we propose a novel algorithm that can detect systolic peaks under challenging conditions, as in the case of emergency responders in tropical conditions. Accurate systolic-peak detection is an important first step for the analysis of heart rate variability. Algorithms based on local maxima-minima, first-derivative, and slope sum are evaluated, and a new algorithm is introduced to improve the detection rate. With 40 healthy subjects, the new algorithm demonstrates the highest overall detection accuracy (99.84% sensitivity, 99.89% positive predictivity). Existing algorithms, such as Billauer's, Li's and Zong's, have comparable although lower accuracy. However, the proposed algorithm presents an advantage for real-time applications by avoiding human intervention in threshold determination. For best performance, we show that a combination of two event-related moving averages with an offset threshold has an advantage in detecting systolic peaks, even in heat-stressed PPG signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Braunwald's Heart Disease: A Textbook of Cardiovascular Medicine
Mann, D. L., Zipes, D. P., Libby, P., Bonow, R. O., & D, E. B. M. (2011) · Medical Entomology and Zoology · Cited by 3,745
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206 · cited 1×
“A zero-phase second-order Butterworth filter, with bandpass 0.5–8 Hz, is implemented to remove the baseline wander and high frequencies that do not contribute to the systolic peaks [33].”
MethodInfluentialSelf-citationNoninvasive determination of age-related changes in the human arterial pulse.
Kelly, R., Hayward, C., Avolio, A., & O'Rourke, M. (1989) · Circulation · doi:10.1161/01.cir.80.6.1652 · Cited by 1,141
Advanced Methods And Tools for ECG Data Analysis
Clifford, G. D., Azuaje, F. J., & McSharry, P. (2006) · Cited by 808
Takazawa, K., Tanaka, N., Fujita, M., Matsuoka, O., Saiki, T., Aikawa, M., Tamura, S., & Ibukiyama, C. (1998) · Hypertension · doi:10.1161/01.hyp.32.2.365 · Cited by 589
Darne, B., Girerd, X., Safar, M., Cambien, F., & Guize, L. (1989) · Hypertension · doi:10.1161/01.hyp.13.4.392 · Cited by 542
Heart Disease: A Textbook of Cardiovascular Medicine. 7th Edition
Bonow, R. O., Zipes, D. P., Libby, P., Ro, B., & Braunwald, E. (2004) · Cited by 397
An open-source algorithm to detect onset of arterial blood pressure pulses
Zong, W., Heldt, T., Moody, G. B., & Mark, R. G. (2003) · Computers in Cardiology, 2003 · doi:10.1109/cic.2003.1291140 · Cited by 320
Bortolotto, L. A., Blacher, J., Kondo, T., Takazawa, K., & Safar, M. E. (2000) · American Journal of Hypertension · doi:10.1016/s0895-7061(99)00192-2 · Cited by 273
Fast QRS Detection with an Optimized Knowledge-Based Method: Evaluation on 11 Standard ECG Databases
Elgendi, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073557 · Cited by 264
Self-citationOn an automatic delineator for arterial blood pressure waveforms
Li, B. N., Dong, M. C., & Vai, M. I. (2010) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2009.06.002 · Cited by 166
Identification of pharmaceutical tablets by Raman spectroscopy and chemometrics
Roggo, Y., Dégardin, K., & Margot, P. A. (2010) · Talanta · doi:10.1016/j.talanta.2010.01.046 · Cited by 150
O’Rourke, M. F., Kelly, R. P., & Avolio, A. P. (1991) · Cited by 148
FREQUENCY BANDS EFFECTS ON QRS DETECTION
Elgendi, M., Jonkman, M., & Boer, F. D. (2010) · International Conference on Bio-inspired Systems and Signal Processing · doi:10.5220/0002742704280431 · Cited by 147
Self-citationIMANAGA, I., HARA, H., KOYANAGI, S., & TANAKA, K. (1998) · Japanese Heart Journal · doi:10.1536/ihj.39.775 · Cited by 118
Cholesterol and Arterial Distensibility in the First Decade of Life
Leeson, C. P. M., Whincup, P. H., Cook, D. G., Mullen, M., Donald, A. E., Seymour, C. A., & Deanfield, J. E. (2000) · Circulation · doi:10.1161/01.cir.101.13.1533 · Cited by 118
Otsuka, T., Kawada, T., Katsumata, M., & Ibuki, C. (2006) · Circulation Journal · doi:10.1253/circj.70.304 · Cited by 102
Standard Terminologies for Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312803217184 · Cited by 52
Self-citationR wave detection using Coiflets wavelets
Elgendi, M., Jonkman, M., & Boer, F. D. (2009) · IEEE Annual Northeast Bioengineering Conference (NEBEC) · doi:10.1109/nebc.2009.4967756 · Cited by 47
Self-citationDifferent effects of hypertension, atherosclerosis and hyperlipidaemia on arterial distensibility
Hoeks, A. P. G., Barenbrock, M., Spieker, C., Kerber, S., Vielhauer, C., Zidek, W., & Rahn, K. H. (1995) · Journal of Hypertension · doi:10.1097/00004872-199512010-00037 · Cited by 43
Kimm, S. Y. S., Payne, G. H., Stylianou, M. P., Waclawiw, M. A., & Lichtenstein, C. (1998) · PEDIATRICS · doi:10.1542/peds.102.5.e50 · Cited by 39
Heart Rate Variability and the Acceleration Plethysmogram Signals Measured at Rest
Elgendi, M., Jonkman, M., & Boer, F. D. (2011) · Communications in computer and information science · doi:10.1007/978-3-642-18472-7_21 · Cited by 35
Self-citationForearm arterial compliance: a new measure of arterial compliance?
Dh, F. (1984) · Cardiovascular Research · doi:10.1093/cvr/18.11.651 · Cited by 30
Measurement of the left ventricular ejection time by digital plethysmography
Chirife, R., Pigott, V. M., & Spodick, D. H. (1971) · American Heart Journal · doi:10.1016/0002-8703(71)90269-9 · Cited by 26
HEART RATE VARIABILITY MEASUREMENT USING THE SECOND DERIVATIVE PHOTOPLETHYSMOGRAM
Elgendi, M., Jonkman, M., & Boer, F. D. (2010) · International Conference on Bio-inspired Systems and Signal Processing · doi:10.5220/0002743300820087 · Cited by 24
Self-citationAn algorithm of echo steganalysis based on Bayes classifier
Zeng, W., Ai, H., Hu, R., et al. (2008) · International Conference on Information and Automation · doi:10.1109/icinfa.2008.4608272 · Cited by 20
Automatic Physiological Waveform Processing for fMRI Noise Correction and Analysis
Kelley, D. J., Oakes, T. R., Greischar, L. L., Chung, M. K., Ollinger, J. M., Alexander, A. L., Shelton, S. E., Kalin, N. H., & Davidson, R. J. (2008) · PLoS ONE · doi:10.1371/journal.pone.0001751 · Cited by 17
Measurement of a-a Intervals at Rest in the Second Derivative Plethysmogram
Elgendi, M., Jonkman, M., & Boer, F. D. (2009) · Cited by 16
Self-citationDevelopment of a stand-alone pulse oximeter
Domingues, A. R. C. (2009) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 3
Cited by
Blood Pressure Estimation from Photoplethysmogram Using a Spectro-Temporal Deep Neural Network
Slapničar, G., Mlakar, N., & Luštrek, M. (2019) · Sensors · doi:10.3390/s19153420 · Cited by 387
“The segmentation was conducted using a peak and valley detector proposed by Elgendi et al. [26].”
MethodOptimal Signal Quality Index for Photoplethysmogram Signals
Elgendi, M. (2016) · Bioengineering · doi:10.3390/bioengineering3040021 · Cited by 320
Self-citationWearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250
“moving average schemes can be designed according to the typical durations of the systolic peak and heartbeat, respectively [98].”
InfluentialAn optimal filter for short photoplethysmogram signals
Liang, Y., Elgendi, M., Chen, Z., & Ward, R. (2018) · Scientific Data · doi:10.1038/sdata.2018.76 · Cited by 242
Self-citationPhotoplethysmography and Deep Learning: Enhancing Hypertension Risk Stratification
Liang, Y., Chen, Z., Ward, R., & Elgendi, M. (2018) · Biosensors · doi:10.3390/bios8040101 · Cited by 166
“The limitations of using feature extraction are (1) the feature points of each heartbeat needed to be extracted correctly [25–27], (2) the ECG and PPG signals have to be of high quality, and (3) optimal filtering is required [28–31].”
MethodSelf-citation
Metadata
- Authors
- Elgendi, M., Norton, I., Brearley, M., Abbott, D., & Schuurmans, D.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2013-10-22
- Volume
- 8
- Issue
- 10
- Pages
- e76585
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2087522345
- Cited by
- 276
- References
- 30
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.