The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
An open-source algorithm to detect onset of arterial blood pressure pulses
Abstract
In this paper, we present an effective algorithm for detecting the onset of arterial blood pressure (ABP) pulses. The algorithm employs a windowed and weighted slope sum function (SSF) to extract ABP waveform features. Adaptive thresholding and search strategies are applied to the SSF signal to detect ABP pulses and to determine their onsets. Two evaluation procedures were employed. First, pulse detection accuracy was evaluated by comparing the algorithm's pulse detections with reference ECG annotations using the MIT-BIH Polysomnographic Database. The algorithm detected 99.31% of the 368,364 beats annotated in the ECG. Second, the accuracy of pulse onset determination was established using a newly created, manually-edited reference ABP signal database. For 96.41% of the 39,848 beats in the reference database, the difference between the manually-edited and algorithm-determined ABP pulse onset was less than or equal to 20 ms. The C source code of the algorithm has been contributed to PhysioToolkit and is freely available from the PhysioNet website (http://www.physionet.org).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Self-citationAsmar, R., Benetos, A., Topouchian, J., Laurent, P., Pannier, B., Brisac, A.-M., Target, R., & Levy, B. I. (1995) · Hypertension · doi:10.1161/01.hyp.26.3.485 · Cited by 1,376
Development of the polysomnographic database on CD‐ROM
Ichimaru, Y., & Moody, G. B. (1999) · Psychiatry and Clinical Neurosciences · doi:10.1046/j.1440-1819.1999.00527.x · Cited by 292
Self-citationO’Rourke, M. F., Kelly, R. P., & Avolio, A. P. (1991) · Cited by 148
Mechanisms of Blood Pressure Waves.
Resmini, D. C. D. (1985) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(85)80032-5 · Cited by 130
Online digital filters for biological signals: some fast designs for a small computer
Lynn, P. A. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442281 · Cited by 104
Mechanisms of blood pressure waves
(1986) · Comparative Biochemistry and Physiology Part A Physiology · doi:10.1016/0300-9629(86)90743-7 · Cited by 72
A real-time algorithm for the quantification of blood pressure waveforms
Navakatikyan, M., Barrett, C. J., Head, G. A., Ricketts, J. H., & Malpas, S. C. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.1010849 · Cited by 56
Assessment of arterial distensibility by automatic pulse wave velocity measurement.
Lehmann, E. D., Hopkins, K. D., & Gosling, R. G. (1996) · PubMed · Cited by 38
Cited by
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
How accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661
Li, Q., Mark, R. G., & Clifford, G. D. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/1/002 · Cited by 426
Self-citationToward a Robust Estimation of Respiratory Rate From Pulse Oximeters
Pimentel, M. A. F., Johnson, A. E. W., Charlton, P. H., Birrenkott, D., Watkinson, P. J., Tarassenko, L., & Clifton, D. A. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2613124 · Cited by 387
Bota, P. J., Wang, C., Fred, A. L. N., & Placido Da Silva, H. (2019) · IEEE Access · doi:10.1109/access.2019.2944001 · Cited by 322
Metadata
- Authors
- Zong, W., Heldt, T., Moody, G. B., & Mark, R. G.
- Venue
- Computers in Cardiology, 2003
- Publisher
- IEEE
- Published
- 2003
- Pages
- 259-262
- ISSN
- 0276-6574 (ISSN-L)
- OpenAlex
- W2170195027
- Cited by
- 320
- References
- 9
- FWCI
- 10.41
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An open-source algorithm to detect onset of arterial blood pressure pulses. https://app.cochat.ai/papers/10.1109/cic.2003.1291140
- The paper
- Zong, W., Heldt, T., Moody, G. B., & Mark, R. G. (2003). An open-source algorithm to detect onset of arterial blood pressure pulses. Computers in Cardiology, 2003. https://doi.org/10.1109/cic.2003.1291140
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.