The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Knee Adduction Moment and Medial Contact Force – Facts about Their Correlation during Gait
Open accessAbstract
The external knee adduction moment is considered a surrogate measure for the medial tibiofemoral contact force and is commonly used to quantify the load reducing effect of orthopedic interventions. However, only limited and controversial data exist about the correlation between adduction moment and medial force. The objective of this study was to examine whether the adduction moment is indeed a strong predictor for the medial force by determining their correlation during gait. Instrumented knee implants with telemetric data transmission were used to measure tibiofemoral contact forces in nine subjects. Gait analyses were performed simultaneously to the joint load measurements. Skeletal kinematics, as well as the ground reaction forces and inertial parameters, were used as inputs in an inverse dynamics approach to calculate the external knee adduction moment. Linear regression analysis was used to analyze the correlation between adduction moment and medial force for the whole stance phase and separately for the early and late stance phase. Whereas only moderate correlations between adduction moment and medial force were observed throughout the whole stance phase (R(2) = 0.56) and during the late stance phase (R(2) = 0.51), a high correlation was observed at the early stance phase (R(2) = 0.76). Furthermore, the adduction moment was highly correlated to the medial force ratio throughout the whole stance phase (R(2) = 0.75). These results suggest that the adduction moment is a surrogate measure, well-suited to predicting the medial force ratio throughout the whole stance phase or medial force during the early stance phase. However, particularly during the late stance phase, moderate correlations and high inter-individual variations revealed that the predictive value of the adduction moment is limited. Further analyses are necessary to examine whether a combination of other kinematic, kinetic or neuromuscular factors may lead to a more reliable prediction of the force magnitude.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miyazaki, T., Wada, M., Kawahara, H., Sato, M., Baba, H., & Shimada, S. (2002) · Annals of the Rheumatic Diseases · doi:10.1136/ard.61.7.617 · Cited by 1,441
A Framework for the in Vivo Pathomechanics of Osteoarthritis at the Knee
Andriacchi, T. P., Mündermann, A., Smith, R. L., Alexander, E. J., Dyrby, C. O., & Koo, S. (2004) · Annals of Biomedical Engineering · doi:10.1023/b:abme.0000017541.82498.37 · Cited by 1,062
Interaction between active and passive knee stabilizers during level walking
Schipplein, O. D., & Andriacchi, T. P. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090114 · Cited by 1,019
Loading of the Knee Joint during Activities of Daily Living Measured In Vivo in Five Subjects
Kutzner, I., Heinlein, B., Graichen, F., Bender, A., Rohlmann, A., Halder, A., Beier, A., & Bergmann, G. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.03.046 · Cited by 798
Sharma, L., Hurwitz, D. E., Thonar, E. J.-M. A., Sum, J. A., Lenz, M. E., Dunlop, D. D., Schnitzer, T. J., Kirwan-Mellis, G., & Andriacchi, T. P. (1998) · Arthritis & Rheumatism · doi:10.1002/1529-0131(199807)41:7<1233::aid-art14>3.0.co;2-l · Cited by 708
Gait characteristics of patients with knee osteoarthritis
Kaufman, K. R., Hughes, C., Morrey, B. F., Morrey, M., & An, K.-N. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00036-7 · Cited by 676
Zhao, D., Banks, S. A., Mitchell, K. H., D'Lima, D. D., Colwell, C. W., & Fregly, B. J. (2007) · Journal of Orthopaedic Research · doi:10.1002/jor.20379 · Cited by 520
Biomechanical considerations in the pathogenesis of osteoarthritis of the knee
Heijink, A., Gomoll, A. H., Madry, H., Drobnič, M., Filardo, G., Espregueira‐Mendes, J., & Van Dijk, C. N. (2012) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-011-1818-0 · Cited by 416
Decreased knee adduction moment does not guarantee decreased medial contact force during gait
Walter, J. P., D'Lima, D. D., Colwell, C. W., & Fregly, B. J. (2010) · Journal of Orthopaedic Research · doi:10.1002/jor.21142 · Cited by 367
Tibio‐femoral loading during human gait and stair climbing
Taylor, W. R., Heller, M. O., Bergmann, G., & Duda, G. N. (2004) · Journal of Orthopaedic Research · doi:10.1016/j.orthres.2003.09.003 · Cited by 366
Self-citationGait modification strategies for altering medial knee joint load: A systematic review
Simic, M., Hinman, R. S., Wrigley, T. V., Bennell, K. L., & Hunt, M. A. (2011) · Arthritis Care & Research · doi:10.1002/acr.20380 · Cited by 278
Foroughi, N., Smith, R., & Vanwanseele, B. (2009) · The Knee · doi:10.1016/j.knee.2008.12.007 · Cited by 270
Heinlein, B., Kutzner, I., Graichen, F., Bender, A., Rohlmann, A., Halder, A. M., Beier, A., & Bergmann, G. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2009.01.011 · Cited by 200
Self-citationWada, M., Maezawa, Y., Baba, H., Shimada, S., Sasaki, S., & Nose, Y. (2001) · Rheumatology · doi:10.1093/rheumatology/40.5.499 · Cited by 197
Implantable 9-Channel Telemetry System for In Vivo Load Measurements With Orthopedic Implants
Graichen, F., Arnold, R., Rohlmann, A., & Bergmann, G. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886857 · Cited by 173
Self-citationInfluence of Limb Alignment on Mediolateral Loading in Total Knee Replacement
Halder, A. M., Kutzner, I., Graichen, F., Heinlein, B., Beier, A., & Bergmann, G. (2012) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.k.00927 · Cited by 156
Self-citationDesign, calibration and pre-clinical testing of an instrumented tibial tray
Heinlein, B., Graichen, F., Bender, A., Rohlmann, A., & Bergmann, G. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.02.014 · Cited by 150
Self-citationTaylor, W. R., Kornaropoulos, E., Duda, G. N., Kratzenstein, S., Ehrig, R. M., Arampatzis, A., & Heller, M. O. W. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.05.005 · Cited by 120
Self-citationPatellofemoral joint contact forces during activities with high knee flexion
Trepczynski, A., Kutzner, I., Kornaropoulos, E., Taylor, W. R., Duda, G. N., Bergmann, G., & Heller, M. O. W. (2011) · Journal of Orthopaedic Research® · doi:10.1002/jor.21540 · Cited by 104
Self-citationThe influence of alignment on the musculo-skeletal loading conditions at the knee
Heller, M. O. W., Taylor, W. R., Perka, C., & Duda, G. N. (2003) · Langenbeck s Archives of Surgery · doi:10.1007/s00423-003-0406-2 · Cited by 70
Self-citationMandeville, D. S., Osternig, L. R., Lantz, B. A., Mohler, C. G., & Chou, L. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.04.011 · Cited by 62
Determination of typical patterns from strongly varying signals
Bender, A., & Bergmann, G. (2011) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2011.560841 · Cited by 51
Self-citationDeuretzbacher, G., & Rehder, U. (1995) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1995.40.4.93 · Cited by 19
Cited by
Chang, A. H., Moisio, K. C., Chmiel, J. S., Eckstein, F., Guermazi, A., Prasad, P. V., Zhang, Y., Almagor, O., Belisle, L., Hayes, K., et al. (2015) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2015.02.005 · Cited by 274
Metadata
- Authors
- Kutzner, I., Trepczynski, A., Heller, M. O., & Bergmann, G.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2013-12-02
- Volume
- 8
- Issue
- 12
- Pages
- e81036
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W1980912454
- Cited by
- 256
- References
- 23
- FWCI
- 6.55
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.