CoChat

Feasibility of Decentralised Deployment of Xpert MTB/RIF Test at Lower Level of Health System in India

Open access
Raizada, Neeraj, Sachdeva, K. S., Sreenivas, Achuthan, Vadera, Bhavin, Gupta, R. S., Parmar, Malik, Kulsange, Shubhangi, Babre, Ameet, Thakur, Rahul, Gray, Christen, Ramachandran, Ranjani, Alavadi, Umesh, Ghedia, Mayank, Vollepore, Balasangameshwara, Dewan, Puneet, Boehme, Catharina, Paramsivan, C. N. · 2014 · PLoS ONE
Cited by 79

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Xpert MTB/RIF is an automated cartridge-based nucleic acid amplification test that has demonstrated its potential to detect tuberculosis and rifampicin resistance with high accuracy. To assist scale-up decisions in India, a feasibility assessment of Xpert MTB/RIF implementation was conducted within microscopy centres of 18 RNTCP TB units. METHODS: As part of programme-based demonstration of Xpert MTB/RIF implementation, we recorded and analysed association between key implementation factors and the ability of test to produce valid results. Factors contributing to test failures were analysed from GeneXpert software data which provides 'failure codes' and causes for test failures. RESULTS: From March'12 to January'13, total 40,035 suspects were tested by Xpert MTB/RIF, and 39,680 (99.1%) received valid results (Cumulative: 37157 (92.8%) on first attempt, 39410 (98.4%) on second attempt, 39637 (99.0%) on third attempt and 39680 (99.1%) on more attempts). Overall initial test failure was 2,878 (7.2% (4%-17%)); of these, 2,594 (90.1%) were re-tested and produced valid results. Most frequent reason of test failure was inadequate sample processing or equipment malfunction (3.9%). Other reasons included power failure (1.1%), cartridge integrity/component failure (0.8%), device-computer communication error (0.5%), and temperature-related errors (0.08%). Significant variation was observed in failure rates both across instruments and over time; furthermore, substantial variation was observed in failure rate in two cartridges lots. CONCLUSION: Installation required minimal infrastructure modifications and concerns about adequacy of human resources under public sector facilities and temperature extremes proved unfounded. Under routine conditions, Xpert MTB/RIF provided 99.1% valid results in TB suspects with low overall failure rates (7.2% initial failure, 0.9% final failure); devices provided valuable real-time feedback on reasons for test failure, which were used for rapid corrective action. High modular replacement (32%) and inter-lot cartridge performance variation remain sources of concern, and warrant close monitoring of failure rates as a key quality indicator.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0089301

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 79

Metadata

Authors
Raizada, N., Sachdeva, K. S., Sreenivas, A., Vadera, B., Gupta, R. S., Parmar, M., Kulsange, S., Babre, A., Thakur, R., Gray, C., Ramachandran, R., Alavadi, U., Ghedia, M., Vollepore, B., Dewan, P., Boehme, C., & Paramsivan, C. N.
Venue
PLoS ONE
Published
2014-02-26
Volume
9
Issue
2
Pages
e89301
ISSN
1932-6203 (ISSN-L)
OpenAlex
W1979130615
Cited by
79
References
2
FWCI
7.57
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.