Foldscope: Origami-Based Paper Microscope
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Here we describe an ultra-low-cost origami-based approach for large-scale manufacturing of microscopes, specifically demonstrating brightfield, darkfield, and fluorescence microscopes. Merging principles of optical design with origami enables high-volume fabrication of microscopes from 2D media. Flexure mechanisms created via folding enable a flat compact design. Structural loops in folded paper provide kinematic constraints as a means for passive self-alignment. This light, rugged instrument can survive harsh field conditions while providing a diversity of imaging capabilities, thus serving wide-ranging applications for cost-effective, portable microscopes in science and education.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Folding DNA to create nanoscale shapes and patterns
Rothemund, P. W. K. (2006) · Nature · doi:10.1038/nature04586 · Cited by 7,354
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Mobile Phone Based Clinical Microscopy for Global Health Applications
Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006320 · Cited by 694
Baron, E. J., Miller, J. M., Weinstein, M. P., Richter, S. S., Gilligan, P. H., Thomson, R. B., Bourbeau, P., Carroll, K. C., Kehl, S. C., Dunne, W. M., et al. (2013) · Clinical Infectious Diseases · doi:10.1093/cid/cit278 · Cited by 592
The Challenge of Education and Learning in the Developing World
Kremer, M., Brannen, C., & Glennerster, R. (2013) · Science · doi:10.1126/science.1235350 · Cited by 493
Geometric Folding Algorithms: Linkages, Origami, Polyhedra
Demaine, E. D., & O'Rourke, J. (2007) · doi:10.1017/cbo9780511735172 · Cited by 433
Geometric Folding Algorithms: Linkages, Origami, Polyhedra
Demaine, E. D., & O’Rourke, J. (2007) · Cited by 410
Optical imaging techniques for point-of-care diagnostics
Zhu, H., Isikman, S. O., Mudanyali, O., Greenbaum, A., & Ozcan, A. (2013) · Lab Chip · doi:10.1039/c2lc40864c · Cited by 364
Cell-Phone-Based Platform for Biomedical Device Development and Education Applications
Smith, Z. J., Chu, K., Espenson, A. R., Rahimzadeh, M., Gryshuk, A., Molinaro, M., Dwyre, D. M., Lane, S., Matthews, D., & Wachsmann-Hogiu, S. (2011) · PLoS ONE · doi:10.1371/journal.pone.0017150 · Cited by 339
Whitney, J. P., Sreetharan, P. S., Ma, K. Y., & Wood, R. J. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/11/115021 · Cited by 242
Cited by
Ozcan, A., & McLeod, E. (2016) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-092515-010849 · Cited by 352
Open Labware: 3-D Printing Your Own Lab Equipment
Baden, T., Chagas, A. M., Gage, G., Marzullo, T., Prieto-Godino, L. L., & Euler, T. (2015) · PLOS Biology · doi:10.1371/journal.pbio.1002086 · Cited by 332
Hand-powered ultralow-cost paper centrifuge
Bhamla, M. S., Benson, B., Chai, C., Katsikis, G., Johri, A., & Prakash, M. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0009 · Cited by 305
Self-citationA review of origami applications in mechanical engineering
Turner, N., Goodwine, B., & Sen, M. (2016) · Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science · doi:10.1177/0954406215597713 · Cited by 223
“Another application of optigami is the Foldscope, which is a flat microscope that can be used to achieve 2000 magnification and submicron resolution.(28) This device can be assembled in about 10min from a flat Figure 8.”
MethodRobotic microscopy for everyone: the OpenFlexure microscope
Collins, J. T., Knapper, J., Stirling, J., Mduda, J., Mkindi, C., Mayagaya, V., Mwakajinga, G. A., Nyakyi, P. T., Sanga, V. L., Carbery, D., et al. (2020) · Biomedical Optics Express · doi:10.1364/boe.385729 · Cited by 189
A versatile and customizable low-cost 3D-printed open standard for microscopic imaging
Diederich, B., Lachmann, R., Carlstedt, S., Marsikova, B., Wang, H., Uwurukundo, X., Mosig, A. S., & Heintzmann, R. (2020) · Nature Communications · doi:10.1038/s41467-020-19447-9 · Cited by 164
Detecting Biothreat Agents: From Current Diagnostics to Developing Sensor Technologies
Walper, S. A., Lasarte Aragonés, G., Sapsford, K. E., Brown, C. W., Rowland, C. E., Breger, J. C., & Medintz, I. L. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00420 · Cited by 161
Metadata
- Authors
- Cybulski, J. S., Clements, J., & Prakash, M.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2014-06-18
- Volume
- 9
- Issue
- 6
- Pages
- e98781
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2028664820
- Cited by
- 388
- References
- 17
- FWCI
- 12.42
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.