Robust T1-Weighted Structural Brain Imaging and Morphometry at 7T Using MP2RAGE
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
PURPOSE: To suppress the noise, by sacrificing some of the signal homogeneity for numerical stability, in uniform T1 weighted (T1w) images obtained with the magnetization prepared 2 rapid gradient echoes sequence (MP2RAGE) and to compare the clinical utility of these robust T1w images against the uniform T1w images. MATERIALS AND METHODS: 8 healthy subjects (29.0 ± 4.1 years; 6 Male), who provided written consent, underwent two scan sessions within a 24 hour period on a 7T head-only scanner. The uniform and robust T1w image volumes were calculated inline on the scanner. Two experienced radiologists qualitatively rated the images for: general image quality; 7T specific artefacts; and, local structure definition. Voxel-based and volume-based morphometry packages were used to compare the segmentation quality between the uniform and robust images. Statistical differences were evaluated by using a positive sided Wilcoxon rank test. RESULTS: The robust image suppresses background noise inside and outside the skull. The inhomogeneity introduced was ranked as mild. The robust image was significantly ranked higher than the uniform image for both observers (observer 1/2, p-value = 0.0006/0.0004). In particular, an improved delineation of the pituitary gland, cerebellar lobes was observed in the robust versus uniform T1w image. The reproducibility of the segmentation results between repeat scans improved (p-value = 0.0004) from an average volumetric difference across structures of ≈ 6.6% to ≈ 2.4% for the uniform image and robust T1w image respectively. CONCLUSIONS: The robust T1w image enables MP2RAGE to produce, clinically familiar T1w images, in addition to T1 maps, which can be readily used in uniform morphometry packages.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Alzheimer’s disease neuroimaging initiative (ADNI): MRI methods
Jack, C. R., Bernstein, M. A., Fox, N. C., Thompson, P., Alexander, G., Harvey, D., Borowski, B., Britson, P. J., L. Whitwell, J., Ward, C., et al. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21049 · Cited by 4,347 · cited 1×
“The scoring system was based on the ADNI rating system: 0 = severe, 1 = moderate, 2 = mild and 3 = none [15].”
MethodThe rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494 · cited 1×
“This, added to the fact that the phase points in any arbitrary direction when the SNR is very low [12] means that the noise takes on a ‘‘salt and pepper’’ characteristic, spreading across the range of 20.”
BackgroundMP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high field
Marques, J. P., Kober, T., Krueger, G., van der Zwaag, W., Van de Moortele, P.-F., & Gruetter, R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.002 · Cited by 1,453 · cited 5×
“In addition to the estimation of a quantitative T1map, the ratio of the two image volumes was shown to correct for the proton density, T2* contrast, and B1 inhomogeneities [4,7].”
BackgroundMethodInfluentialSelf-citationThree‐dimensional magnetization‐prepared rapid gradient‐echo imaging (3D MP RAGE)
Mugler, J. P., & Brookeman, J. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910150117 · Cited by 1,265 · cited 7×
“Whilst in the robust T1w image it appears as a signal loss, similar to MPRAGE.”
BackgroundInfluentialMueller, S. G., Weiner, M. W., Thal, L. J., Petersen, R. C., Jack, C. R., Jagust, W., Trojanowski, J. Q., Toga, A. W., & Beckett, L. (2005) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2005.06.003 · Cited by 1,233 · cited 2×
“The anonymized and randomized images were rated for: i) general image quality, in line with the quality rating procedure employed in ADNI [14], ii) 7T specific artifacts including residual inversion, susceptibility and intensity inhomogeneity, and; iii) the definition of local structures including the hippocampus, tha…”
Method7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890 · cited 1×
“At high magnetic fields, structural whole brain T1-weighted (T1w) images are more prone to signal variations due to presence of larger inhomogeneity of the static magnetic field (DB0), the transmit (B1) and the receive (B1(2)) radio frequency field inhomogeneities [1].”
BackgroundB1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil
Van de Moortele, P., Akgun, C., Adriany, G., Moeller, S., Ritter, J., Collins, C. M., Smith, M. B., Vaughan, J. T., & Uğurbil, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20708 · Cited by 468 · cited 1×
“3T) the B1+ and B1(2) field variations are more pronounced [6].”
BackgroundVan de Moortele, P.-F., Auerbach, E. J., Olman, C., Yacoub, E., Uğurbil, K., & Moeller, S. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.009 · Cited by 265 · cited 6×
“In addition to the estimation of a quantitative T1map, the ratio of the two image volumes was shown to correct for the proton density, T2* contrast, and B1 inhomogeneities [4,7].”
BackgroundMethodInfluentialIntensity non-uniformity correction in MRI: Existing methods and their validation
Belaroussi, B., Milles, J., Carme, S., Zhu, Y. M., & Benoit-Cattin, H. (2006) · Medical Image Analysis · doi:10.1016/j.media.2005.09.004 · Cited by 249
Rapid three‐dimensional T1‐weighted MR imaging with the MP‐RAGE sequence
Mugler, J. P., & Brookeman, J. R. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010509 · Cited by 174 · cited 7×
“Whilst in the robust T1w image it appears as a signal loss, similar to MPRAGE.”
BackgroundInfluential
Cited by
Kim, E., Di Censo, D., Baraldo, M., Simmons, C., Rosa, I., Randall, K., Ballard, C., Dickie, B. R., Williams, S. C. R., Killick, R., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-91899-5 · Cited by 15
Nguyen, J. Q., Riddle, T., Nguyen, N., Chao, S., Dutta, D., Hill, A., Yu, R., Rowland, K., & Shi, Z. (2025) · Scientific Reports · doi:10.1038/s41598-025-15547-y · Cited by 3
Metadata
- Authors
- O'Brien, K. R., Kober, T., Hagmann, P., Maeder, P., Marques, J., Lazeyras, F., Krueger, G., & Roche, A.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2014-06-16
- Volume
- 9
- Issue
- 6
- Pages
- e99676
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2052115682
- Cited by
- 179
- References
- 13
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robust T1-Weighted Structural Brain Imaging and Morphometry at 7T Using MP2RAGE. https://app.cochat.ai/papers/10.1371/journal.pone.0099676
- The paper
- O'Brien, K. R., Kober, T., Hagmann, P., Maeder, P., Marques, J., Lazeyras, F., Krueger, G., & Roche, A. (2014). Robust T1-Weighted Structural Brain Imaging and Morphometry at 7T Using MP2RAGE. PLoS ONE. https://doi.org/10.1371/journal.pone.0099676
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.