Effect of Time of Day on Performance, Hormonal and Metabolic Response during a 1000-M Cycling Time Trial
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The aim of this study was to determine the effect of time of day on performance, pacing, and hormonal and metabolic responses during a 1000-m cycling time-trial. Nine male, recreational cyclists visited the laboratory four times. During the 1st visit the participants performed an incremental test and during the 2nd visit they performed a 1000-m cycling familiarization trial. On the 3rd and 4th visits, the participants performed a 1000-m TT at either 8 am or 6 pm, in randomized, repeated-measures, crossover design. The time to complete the time trial was lower in the evening than in the morning (88.2±8.7 versus 94.7±10.9 s, respectively, p<0.05), but there was no significant different in pacing. However, oxygen uptake and aerobic mechanical power output at 600 and 1000 m tended to be higher in the evening (p<0.07 and 0.09, respectively). There was also a main effect of time of day for insulin, cortisol, and total and free testosterone concentration, which were all higher in the morning (+60%, +26%, +31% and +22%, respectively, p<0.05). The growth hormone, was twofold higher in the evening (p<0.05). The plasma glucose was ∼11% lower in the morning (p<0.05). Glucagon, norepinephrine, epinephrine and lactate were similar for the morning and evening trials (p>0.05), but the norepinephrine response to the exercise was increased in the morning (+46%, p<0.05), and it was accompanied by a 5-fold increase in the response of glucose. Muscle recruitment, as measured by electromyography, was similar between morning and evening trials (p>0.05). Our findings suggest that performance was improved in the evening, and it was accompanied by an improved hormonal and metabolic milieu.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of recommendations for SEMG sensors and sensor placement procedures
Hermens, H. J., Freriks, B., Disselhorst-Klug, C., & Rau, G. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00027-4 · Cited by 7,213 · cited 1×
“The skin preparation, placement and location of the electrodes were in accordance with the recommendations of SENIAM [21].”
MethodMeasures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635 · cited 1×
“The sample size required was estimated from the equation n = 8e(2)/d(2) [23], where n, e, and d denote predicted sample size, coefficient of variation, and the magnitude of the treatment effect, respectively.”
MethodNeural adaptation to resistance training
SALE, D. G. (1988) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198810001-00009 · Cited by 1,421
Impact of the human circadian system, exercise, and their interaction on cardiovascular function
Scheer, F. A. J. L., Hu, K., Evoniuk, H., Kelly, E. E., Malhotra, A., Hilton, M. F., & Shea, S. A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1006749107 · Cited by 332
Relationship between fatty acid delivery and fatty acid oxidation during strenuous exercise
Romijn, J. A., Coyle, E. F., Sidossis, L. S., Zhang, X. J., & Wolfe, R. R. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.79.6.1939 · Cited by 248 · cited 1×
“A reduced GH concentration in the morning may have contributed to the reduced plasma glucose concentration [28,29,30].”
BackgroundHormonal and metabolic responses to exercise across time of day and menstrual cycle phase
Galliven, E. A., Singh, A., Michelson, D., Bina, S., Gold, P. W., & Deuster, P. A. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.6.1822 · Cited by 116 · cited 1×
“On the other hand, growth hormone (GH) seems to be slightly reduced in the morning, but its response to exercise is not altered [13].”
Background
Cited by
Circadian rhythms and exercise — re-setting the clock in metabolic disease
Gabriel, B. M., & Zierath, J. R. (2019) · Nature Reviews Endocrinology · doi:10.1038/s41574-018-0150-x · Cited by 382
Caffeine and Exercise: What Next?
Pickering, C., & Grgic, J. (2019) · Sports Medicine · doi:10.1007/s40279-019-01101-0 · Cited by 158
Noone, J., Mucinski, J. M., DeLany, J. P., Sparks, L. M., & Goodpaster, B. H. (2024) · Cell Metabolism · doi:10.1016/j.cmet.2023.12.025 · Cited by 128
How much does sleep deprivation impair endurance performance? A systematic review and meta-analysis
Lopes, T. R., Pereira, H. M., Bittencourt, L. R. A., & Silva, B. M. (2023) · European Journal of Sport Science · doi:10.1080/17461391.2022.2155583 · Cited by 30
Metadata
- Authors
- Fernandes, A. L., Lopes-Silva, J. P., Bertuzzi, R., Casarini, D. E., Arita, D. Y., Bishop, D. J., & Lima-Silva, A. E.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2014-10-07
- Volume
- 9
- Issue
- 10
- Pages
- e109954
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W1982600989
- Cited by
- 108
- References
- 6
- FWCI
- 7.21
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.