Air Displacement Plethysmography versus Dual-Energy X-Ray Absorptiometry in Underweight, Normal-Weight, and Overweight/Obese Individuals
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Accurately estimating fat percentage is important for assessing health and determining treatment course. Methods of estimating body composition such as hydrostatic weighing or dual-energy x-ray absorptiometry (DXA), however, can be expensive, require extensive operator training, and, in the case of hydrostatic weighing, be highly burdensome for patients. Our objective was to evaluate air displacement plethysmography via the Bod Pod, a less burdensome method of estimating body fat percentage. In particular, we filled a gap in the literature by testing the Bod Pod at the lower extreme of the Body Mass Index (BMI) distribution. FINDINGS: Three BMI groups were recruited and underwent both air displacement plethysmography and dual-energy x-ray absorptiometry. We recruited 30 healthy adults at the lower BMI distribution from the Calorie Restriction (CR) Society and followers of the CR Way. We also recruited 15 normal weight and 19 overweight/obese healthy adults from the general population. Both Siri and Brozek equations derived body fat percentage from the Bod Pod, and Bland-Altman analyses assessed agreement between the Bod Pod and DXA. Compared to DXA, the Bod Pod overestimated body fat percentage in thinner participants and underestimated body fat percentage in heavier participants, and the magnitude of difference was larger for underweight BMI participants, reaching 13% in some. The Bod Pod and DXA had smaller discrepancies in normal weight and overweight/obese participants. CONCLUSIONS: While less burdensome, clinicians should be aware that Bod Pod estimates may deviate from DXA estimates particularly at the lower end of the BMI distribution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A new air displacement method for the determination of human body composition
DEMPSTER, P., & AITKENS, S. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199512000-00017 · Cited by 678
Body-composition assessment via air-displacement plethysmography in adults and children: a review
Fields, D. A., Goran, M. I., & McCrory, M. A. (2002) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/75.3.453 · Cited by 638 · cited 1×
“Second, while the Bod Pod has been validated in a number of studies for normal weight populations [7,8], much of the research focus in validating the Bod Pod has been in obese populations [9,10].”
Dual-energy X-ray absorptiometry body composition model: review of physical concepts
Pietrobelli, A., Formica, C., Wang, Z., & Heymsfield, S. B. (1996) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1996.271.6.e941 · Cited by 594
Use of dual-energy x-ray absorptiometry in body-composition studies: not yet a “gold standard”
Roubenoff, R., Kehayias, J., Dawson-Hughes, B., & Heymsfield, S. (1993) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/58.5.589 · Cited by 369
Vescovi, J. D., Zimmerman, S. L., Miller, W. C., Hildebrandt, L., Hammer, R. L., & Fernhall, B. (2001) · European Journal of Applied Physiology · doi:10.1007/s004210100459 · Cited by 98
Hames, K. C., Anthony, S. J., Thornton, J. C., Gallagher, D., & Goodpaster, B. H. (2014) · Obesity · doi:10.1002/oby.20655 · Cited by 24
Cited by
Garvey, W. T., Mechanick, J. I., Brett, E. M., Garber, A. J., Hurley, D. L., Jastreboff, A. M., Nadolsky, K., Pessah-Pollack, R., & Plodkowski, R. (2016) · Endocrine Practice · doi:10.4158/ep161365.gl · Cited by 1,914
Automated Abdominal Segmentation of CT Scans for Body Composition Analysis Using Deep Learning
Weston, A. D., Korfiatis, P., Kline, T. L., Philbrick, K. A., Kostandy, P., Sakinis, T., Sugimoto, M., Takahashi, N., & Erickson, B. J. (2019) · Radiology · doi:10.1148/radiol.2018181432 · Cited by 358
Kasper, A. M., Langan-Evans, C., Hudson, J. F., Brownlee, T. E., Harper, L. D., Naughton, R. J., Morton, J. P., & Close, G. L. (2021) · Nutrients · doi:10.3390/nu13041075 · Cited by 196
“When estimating adiposity in comparison to DXA, which will be covered later in this review, ADP diverges at the extremes of the BMI spectrum [24], which may be a cause for concern when used with certain athletic populations.”
BackgroundMeasuring Muscle Mass and Strength in Obesity: a Review of Various Methods
Sizoo, D., de Heide, L. J. M., Emous, M., van Zutphen, T., Navis, G., & van Beek, A. P. (2021) · Obesity Surgery · doi:10.1007/s11695-020-05082-2 · Cited by 77
Smartphone camera based assessment of adiposity: a validation study
Majmudar, M. D., Chandra, S., Yakkala, K., Kennedy, S., Agrawal, A., Sippel, M., Ramu, P., Chaudhri, A., Smith, B., Criminisi, A., et al. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00628-3 · Cited by 75
Metadata
- Authors
- Lowry, D. W., & Tomiyama, A. J.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-01-21
- Volume
- 10
- Issue
- 1
- Pages
- e0115086
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2157514554
- Cited by
- 63
- References
- 7
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.