CoChat

Microcirculation-on-a-Chip: A Microfluidic Platform for Assaying Blood- and Lymphatic-Vessel Permeability

Open access
Sato, Miwa, Sasaki, Naoki, Ato, Manabu, Hirakawa, Satoshi, Sato, Kiichi, Sato, Kae · 2015 · PLOS ONE

The DOI matches its Crossref record; 58 of the 59 references it cites were found in a registry or an index.

Abstract

We developed a microfluidic model of microcirculation containing both blood and lymphatic vessels for examining vascular permeability. The designed microfluidic device harbors upper and lower channels that are partly aligned and are separated by a porous membrane, and on this membrane, blood vascular endothelial cells (BECs) and lymphatic endothelial cells (LECs) were cocultured back-to-back. At cell-cell junctions of both BECs and LECs, claudin-5 and VE-cadherin were detected. The permeability coefficient measured here was lower than the value reported for isolated mammalian venules. Moreover, our results showed that the flow culture established in the device promoted the formation of endothelial cell-cell junctions, and that treatment with histamine, an inflammation-promoting substance, induced changes in the localization of tight and adherens junction-associated proteins and an increase in vascular permeability in the microdevice. These findings indicated that both BECs and LECs appeared to retain their functions in the microfluidic coculture platform. Using this microcirculation device, the vascular damage induced by habu snake venom was successfully assayed, and the assay time was reduced from 24 h to 30 min. This is the first report of a microcirculation model in which BECs and LECs were cocultured. Because the micromodel includes lymphatic vessels in addition to blood vessels, the model can be used to evaluate both vascular permeability and lymphatic return rate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0137301

Cites

58 of 58 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig 1 Experimental design. (a) Schematic of a membrane-integrated microfluidic device. (b) Experimental procedure used for coculturing BECs (cells in red) and LECs (cells in green) on opposite sides of the membrane in the microfluidic device.
Fig 1 Experimental design. (a) Schematic of a membrane-integrated microfluidic device. (b) Experimental procedure used for coculturing BECs (cells in red) and LECs (cells in green) on opposite sides of the membrane in the microfluidic device.CC BY · PubMed Central
Fig 2 Characterization of BECs and LECs cocultured in the microfluidic device. (a) Schematic of the microfluidic device. The cells in red are BECs and the cells in green are LECs. (b) Live/dead analysis. (c) Detection of the lymphatic endothelium by immunostaining for a lymphatic marker, podoplanin. (d) Detection of an endothelial-specific protein, claudin-5, by immunostaining. (e) Detection of an endothelial-specific adhesion molecule, VE-cadherin, by immunostaining.
Fig 2 Characterization of BECs and LECs cocultured in the microfluidic device. (a) Schematic of the microfluidic device. The cells in red are BECs and the cells in green are LECs. (b) Live/dead analysis. (c) Detection of the lymphatic endothelium by immunostaining for a lymphatic marker, podoplanin. (d) Detection of an endothelial-specific protein, claudin-5, by immunostaining. (e) Detection of an endothelial-specific adhesion molecule, VE-cadherin, by immunostaining.CC BY · PubMed Central
Fig 3 Permeability measured using the microfluidic system lacking or containing BECs and LECs. No cells (x), BEC monolayer (yellow triangles), BEC-LEC coculture (blue diamonds), and BEC-BEC coculture (pink squares). The values are presented as means ± SD. The fluorescent tracers used were (a) TRITC-dextran and (b) Lucifer Yellow. The statistical significance of the differences between the values obtained at 60 min was evaluated using t tests: (a) P < 0.005, between No cells and BEC monolayer; P < 0.001, between BEC monolayer and BEC-LEC coculture; and P < 0.32, between BEC-LEC coculture and BEC-BEC coculture. (b) P < 0.001, between No cells and BEC monolayer; P < 0.001, between BEC monolayer and BEC-LEC coculture; and P < 0.45, between BEC-LEC coculture and BEC-BEC coculture. Each data point was obtained from three devices (n = 3).
Fig 3 Permeability measured using the microfluidic system lacking or containing BECs and LECs. No cells (x), BEC monolayer (yellow triangles), BEC-LEC coculture (blue diamonds), and BEC-BEC coculture (pink squares). The values are presented as means ± SD. The fluorescent tracers used were (a) TRITC-dextran and (b) Lucifer Yellow. The statistical significance of the differences between the values obtained at 60 min was evaluated using t tests: (a) P < 0.005, between No cells and BEC monolayer; P < 0.001, between BEC monolayer and BEC-LEC coculture; and P < 0.32, between BEC-LEC coculture and BEC-BEC coculture. (b) P < 0.001, between No cells and BEC monolayer; P < 0.001, between BEC monolayer and BEC-LEC coculture; and P < 0.45, between BEC-LEC coculture and BEC-BEC coculture. Each data point was obtained from three devices (n = 3).CC BY · PubMed Central
Fig 4 Permeability measured using the microfluidic system containing BECs and LECs cultured under 3 conditions. Permeability tests were performed after cells were cultured for 24 h (BEC-LEC coculture) under a 1-μL/h pulsating-flow condition generated using a miniaturized infusion pump (pink triangles), a 1-μL/h continuous-flow condition generated using a syringe pump (yellow squares), or the static condition (blue diamonds). The values are presented as means ± SD. The fluorescent tracers used were (a) TRITC-dextran and (b) Lucifer Yellow. The significance of differences between the 60-min values was assessed by performing t tests: (a) P < 0.05, between static condition and continuous-flow condition; and (b) P < 0.05, between static condition and both flow conditions. Each data point was obtained from four devices (n = 4).
Fig 4 Permeability measured using the microfluidic system containing BECs and LECs cultured under 3 conditions. Permeability tests were performed after cells were cultured for 24 h (BEC-LEC coculture) under a 1-μL/h pulsating-flow condition generated using a miniaturized infusion pump (pink triangles), a 1-μL/h continuous-flow condition generated using a syringe pump (yellow squares), or the static condition (blue diamonds). The values are presented as means ± SD. The fluorescent tracers used were (a) TRITC-dextran and (b) Lucifer Yellow. The significance of differences between the 60-min values was assessed by performing t tests: (a) P < 0.05, between static condition and continuous-flow condition; and (b) P < 0.05, between static condition and both flow conditions. Each data point was obtained from four devices (n = 4).CC BY · PubMed Central
Fig 5 Effects of histamine stimulation on BECs and LECs cultured in the microfluidic system. A single-channel device without the permeable membrane was used instead of the coculture device. (a) Fluorescence imaging of BODIPY-FL-histamine bound to its receptor on BECs and LECs. (b) The time course of Ca2+ responses to histamine stimulation observed in BECs and LECs. (c) Immunostaining for claudin-5 and VE-cadherin after histamine stimulation for 30 min.
Fig 5 Effects of histamine stimulation on BECs and LECs cultured in the microfluidic system. A single-channel device without the permeable membrane was used instead of the coculture device. (a) Fluorescence imaging of BODIPY-FL-histamine bound to its receptor on BECs and LECs. (b) The time course of Ca2+ responses to histamine stimulation observed in BECs and LECs. (c) Immunostaining for claudin-5 and VE-cadherin after histamine stimulation for 30 min.CC BY · PubMed Central
Fig 6 Permeability of BECs and LECs measured using the microfluidic system, with or without histamine stimulation. Permeability tests were performed after a 24-h cell culture (BEC-LEC coculture). Histamine (100 mM, red triangles) and control (blue diamonds). The values are presented as means ± SD. The fluorescent tracers used were (a) TRITC-dextran and (b) Lucifer Yellow. The results of t tests showed that the values obtained at 60 min with and without histamine stimulation were significantly different: (a) P < 0.001 and (b) P < 0.01. Each data point was obtained from seven devices (n = 7).
Fig 6 Permeability of BECs and LECs measured using the microfluidic system, with or without histamine stimulation. Permeability tests were performed after a 24-h cell culture (BEC-LEC coculture). Histamine (100 mM, red triangles) and control (blue diamonds). The values are presented as means ± SD. The fluorescent tracers used were (a) TRITC-dextran and (b) Lucifer Yellow. The results of t tests showed that the values obtained at 60 min with and without histamine stimulation were significantly different: (a) P < 0.001 and (b) P < 0.01. Each data point was obtained from seven devices (n = 7).CC BY · PubMed Central
Fig 7 Permeability of BECs and LECs stimulated with or without habu snake venom. Permeability tests were performed after a 24-h cell culture (BEC-LEC coculture). Samples: (yellow squares) and control (blue diamonds). The values are presented as means ± SD. The fluorescent tracers used were (a) TRITC-dextran and (b) Lucifer Yellow. The t-test results showed that the 60-min values obtained without (control) and with stimulation with habu snake venom were significantly different: P < 0.0001, for both (a) and (b). Each data point was obtained from three devices (n = 3).
Fig 7 Permeability of BECs and LECs stimulated with or without habu snake venom. Permeability tests were performed after a 24-h cell culture (BEC-LEC coculture). Samples: (yellow squares) and control (blue diamonds). The values are presented as means ± SD. The fluorescent tracers used were (a) TRITC-dextran and (b) Lucifer Yellow. The t-test results showed that the 60-min values obtained without (control) and with stimulation with habu snake venom were significantly different: P < 0.0001, for both (a) and (b). Each data point was obtained from three devices (n = 3).CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 58 references

Cited by

See all 124

Metadata

Authors
Sato, M., Sasaki, N., Ato, M., Hirakawa, S., Sato, K., & Sato, K.
Affiliations
  • Japan Women's University (JP)
  • National Institute of Infectious Diseases (JP)
  • Hamamatsu University School of Medicine (JP)
  • Gunma University (JP)
Corresponding author
Sato, Kae
Venue
PLOS ONE
Published
2015-09-02
Volume
10
Issue
9
Pages
e0137301
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2152239270
Cited by
124
References
59
Citations by year
2026: 6 · 2025: 7 · 2024: 9 · 2023: 10 · 2022: 13 · 2021: 22 · 2020: 21 · 2019: 9 · 2018: 10 · 2017: 7 · 2016: 8 · 2015: 1
FWCI
4.63
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Figshare (submittedVersion, cc-by)
Funders
  • Suzuken Memorial Foundation
  • Tokyo Ohka Foundation for The Promotion of Science and Technology
  • Japan Society for the Promotion of Science (25600065, 24350035, 15K13719, CREST, 25293227, 15H03823)
  • Core Research for Evolutional Science and Technology
Topics
  • Life Sciences › Neuroscience › Neurology › Barrier Structure and Function Studies
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Health Sciences › Medicine › Oncology › Lymphatic System and Diseases
Keywords
vascular permeability, lymphatic vessels, lymphatic endothelial cells, blood endothelial cells, claudin-5, VE-cadherin, tight junctions, adherens junctions, histamine, inflammation, habu snake venom, microfluidics
MeSH terms
Animals, Capillary Permeability, Cattle, Cells, Cultured, Endothelium, Vascular, Histamine, Humans, Microcirculation, Coculture Techniques, Lymphatic Vessels, Lab-On-A-Chip Devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microcirculation-on-a-Chip: A Microfluidic Platform for Assaying Blood- and Lymphatic-Vessel Permeability. https://app.cochat.ai/papers/10.1371/journal.pone.0137301
The paper
Sato, M., Sasaki, N., Ato, M., Hirakawa, S., Sato, K., & Sato, K. (2015). Microcirculation-on-a-Chip: A Microfluidic Platform for Assaying Blood- and Lymphatic-Vessel Permeability. PLOS ONE. https://doi.org/10.1371/journal.pone.0137301

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.