Microcirculation-on-a-Chip: A Microfluidic Platform for Assaying Blood- and Lymphatic-Vessel Permeability
Open accessThe DOI matches its Crossref record; 58 of the 59 references it cites were found in a registry or an index.
Abstract
We developed a microfluidic model of microcirculation containing both blood and lymphatic vessels for examining vascular permeability. The designed microfluidic device harbors upper and lower channels that are partly aligned and are separated by a porous membrane, and on this membrane, blood vascular endothelial cells (BECs) and lymphatic endothelial cells (LECs) were cocultured back-to-back. At cell-cell junctions of both BECs and LECs, claudin-5 and VE-cadherin were detected. The permeability coefficient measured here was lower than the value reported for isolated mammalian venules. Moreover, our results showed that the flow culture established in the device promoted the formation of endothelial cell-cell junctions, and that treatment with histamine, an inflammation-promoting substance, induced changes in the localization of tight and adherens junction-associated proteins and an increase in vascular permeability in the microdevice. These findings indicated that both BECs and LECs appeared to retain their functions in the microfluidic coculture platform. Using this microcirculation device, the vascular damage induced by habu snake venom was successfully assayed, and the assay time was reduced from 24 h to 30 min. This is the first report of a microcirculation model in which BECs and LECs were cocultured. Because the micromodel includes lymphatic vessels in addition to blood vessels, the model can be used to evaluate both vascular permeability and lymphatic return rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bertrand, N., Wu, J., Xu, X., Kamaly, N., & Farokhzad, O. C. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.11.009 · Cited by 2,824 · cited 1×
“Studies on drug-delivery systems (DDSs) have previously investigated the enhanced permeation and retention effect, which is caused by the presence of imperfect tumor blood vessels and poor lymphatic drainage in tumor tissues [54,55], and a lymphatic system-targeted DDS has also attracted research attention [56].”
BackgroundMaeda, H., Nakamura, H., & Fang, J. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.10.002 · Cited by 2,376 · cited 1×
“Studies on drug-delivery systems (DDSs) have previously investigated the enhanced permeation and retention effect, which is caused by the presence of imperfect tumor blood vessels and poor lymphatic drainage in tumor tissues [54,55], and a lymphatic system-targeted DDS has also attracted research attention [56].”
BackgroundAngiosarcomas Express Mixed Endothelial Phenotypes of Blood and Lymphatic Capillaries
Breiteneder-Geleff, S., Soleiman, A., Kowalski, H., Horvat, R., Amann, G., Kriehuber, E., Diem, K., Weninger, W., Tschachler, E., Alitalo, K., et al. (1999) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)65285-6 · Cited by 1,090 · cited 1×
“Cells cultured in microchannels were immunostained for the lymphatic marker podoplanin [39], and for VE-cadherin/CD144 [40] and claudin-5 [41], which are key components of endothelial adherens and tight junctions, respectively.”
BackgroundIn vitro microvessels for the study of angiogenesis and thrombosis
Zheng, Y., Chen, J., Craven, M., Choi, N. W., Totorica, S., Diaz-Santana, A., Kermani, P., Hempstead, B., Fischbach-Teschl, C., López, J. A., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201240109 · Cited by 894 · cited 2×
“In these previous studies, the culture periods were much longer (4 d [45], 6–7 d [46], or 14 d [44]) than the present work (24 h).”
Engineering of functional, perfusable 3D microvascular networks on a chip
Kim, S., Lee, H., Chung, M., & Jeon, N. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41320a · Cited by 872
Morita, K., Sasaki, H., Furuse, M., & Tsukita, S. (1999) · The Journal of Cell Biology · doi:10.1083/jcb.147.1.185 · Cited by 869 · cited 1×
“Cells cultured in microchannels were immunostained for the lymphatic marker podoplanin [39], and for VE-cadherin/CD144 [40] and claudin-5 [41], which are key components of endothelial adherens and tight junctions, respectively.”
BackgroundCharacterization of a microfluidic in vitro model of the blood-brain barrier (μBBB)
Booth, R., & Kim, H. (2012) · Lab on a Chip · doi:10.1039/c2lc40094d · Cited by 739 · cited 1×
“In previous studies, the response to stimulation by inflammation-promoting substances was confirmed using a vascular model [21][29][46][49].”
BackgroundSTUDIES ON THE QUANTITATIVE METHOD FOR DETERMINATION OF HEMORRHAGIC ACTIVITY OF HABU SNAKE VENOM
KONDO, H., KONDO, S., IKEZAWA, H., MURATA, R., & OHSAKA, A. (1960) · Japanese Journal of Medical Science and Biology · doi:10.7883/yoken1952.13.43 · Cited by 586 · cited 1×
“The anti-hemorrhagic potency test is a major test used for measuring anti-venom activity, and in this test, rabbits are used [50]:}.”
MethodFormation of perfused, functional microvascular tubes in vitro
Chrobak, K. M., Potter, D. R., & Tien, J. (2006) · Microvascular Research · doi:10.1016/j.mvr.2006.02.005 · Cited by 553
Griep, L. M., Wolbers, F., de Wagenaar, B., ter Braak, P. M., Weksler, B. B., Romero, I. A., Couraud, P. O., Vermes, I., van der Meer, A. D., & van den Berg, A. (2013) · Biomedical Microdevices · doi:10.1007/s10544-012-9699-7 · Cited by 537
Cited by
Microfluidic Model Porous Media: Fabrication and Applications
Anbari, A., Chien, H., Datta, S. S., Deng, W., Weitz, D. A., & Fan, J. (2018) · Small · doi:10.1002/smll.201703575 · Cited by 248
Microfluidic modelling of the tumor microenvironment for anti-cancer drug development
Shang, M., Soon, R. H., Lim, C. T., Khoo, B. L., & Han, J. (2019) · Lab on a Chip · doi:10.1039/c8lc00970h · Cited by 227
Azizgolshani, H., Coppeta, J. R., Vedula, E. M., Marr, E. E., Cain, B. P., Luu, R. J., Lech, M. P., Kann, S. H., Mulhern, T. J., Tandon, V., et al. (2021) · Lab on a Chip · doi:10.1039/d1lc00067e · Cited by 225
Organ-on-chip models of cancer metastasis for future personalized medicine: From chip to the patient
Caballero, D., Kaushik, S., Correlo, V. M., Oliveira, J. M., Reis, R. L., & Kundu, S. C. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.005 · Cited by 221
Mechanisms of Nanoparticle Transport across Intestinal Tissue: An Oral Delivery Perspective
Ejazi, S. A., Louisthelmy, R., & Maisel, K. (2023) · ACS Nano · doi:10.1021/acsnano.3c02403 · Cited by 210
A Tumor‐on‐a‐Chip System with Bioprinted Blood and Lymphatic Vessel Pair
Cao, X., Ashfaq, R., Cheng, F., Maharjan, S., Li, J., Ying, G., Hassan, S., Xiao, H., Yue, K., & Zhang, Y. S. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201807173 · Cited by 198
The Importance of Mechanical Forces for in vitro Endothelial Cell Biology
Gordon, E., Schimmel, L., & Frye, M. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00684 · Cited by 171
Cardiovascular organ-on-a-chip platforms for drug discovery and development
Ribas, J., Sadeghi, H., Manbachi, A., Leijten, J., Brinegar, K., Zhang, Y. S., Ferreira, L., & Khademhosseini, A. (2016) · Applied In Vitro Toxicology · doi:10.1089/aivt.2016.0002 · Cited by 161
Bioprinted 3D vascularized tissue model for drug toxicity analysis
Massa, S., Sakr, M. A., Seo, J., Bandaru, P., Arneri, A., Bersini, S., Zare-Eelanjegh, E., Jalilian, E., Cha, B.-H., Antona, S., et al. (2017) · Biomicrofluidics · doi:10.1063/1.4994708 · Cited by 158
In Vitro Strategies to Vascularize 3D Physiologically Relevant Models
Dellaquila, A., Le Bao, C., Letourneur, D., & Simon‐Yarza, T. (2021) · Advanced Science · doi:10.1002/advs.202100798 · Cited by 115
Blood Vessel Organoids for Development and Disease
Salewskij, K., & Penninger, J. M. (2023) · Circulation Research · doi:10.1161/circresaha.122.321768 · Cited by 111
van Dijk, C. G. M., Brandt, M. M., Poulis, N., Anten, J., van der Moolen, M., Kramer, L., Homburg, E. F. G. A., Louzao-Martinez, L., Pei, J., Krebber, M. M., et al. (2020) · Lab on a Chip · doi:10.1039/d0lc00059k · Cited by 103
Advances in microphysiological blood-brain barrier (BBB) models towards drug delivery
Lee, C. S., & Leong, K. W. (2020) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2020.06.009 · Cited by 94
“Physiological response to histamine can be replicated in BBB-chips with TEER drop and dextran permeability spike (Figure 4b) [14,17].”
BackgroundDifferential Monocyte Actuation in a Three‐Organ Functional Innate Immune System‐on‐a‐Chip
Sasserath, T., Rumsey, J. W., McAleer, C. W., Bridges, L. R., Long, C. J., Elbrecht, D., Schuler, F., Roth, A., Bertinetti‐LaPatki, C., Shuler, M. L., et al. (2020) · Advanced Science · doi:10.1002/advs.202000323 · Cited by 91
Microfluidic-based vascularized microphysiological systems
Lee, S., Ko, J., Park, D., Lee, S.-R., Chung, M., Lee, Y., & Jeon, N. L. (2018) · Lab on a Chip · doi:10.1039/c8lc00285a · Cited by 91
Gong, M. M., Lugo-Cintron, K. M., White, B. R., Kerr, S. C., Harari, P. M., & Beebe, D. J. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119225 · Cited by 87
“Other microfluidic models have been developed for examining lymphatic vessel permeability and lymphangiogenesis [22,23]; however, they lack in vivo tubular structure.”
Lim, J., Ching, H., Yoon, J., Jeon, N. L., & Kim, Y. (2021) · Nano Convergence · doi:10.1186/s40580-021-00261-y · Cited by 91
Integration of Extracellular Matrices into Organ‐on‐Chip Systems
Kutluk, H., Bastounis, E. E., & Constantinou, I. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202203256 · Cited by 84
Tumour-vessel-on-a-chip models for drug delivery
Caballero, D., Blackburn, S. M., de Pablo, M., Samitier, J., & Albertazzi, L. (2017) · Lab on a Chip · doi:10.1039/c7lc00574a · Cited by 78
Microfluidic lumen-based systems for advancing tubular organ modeling
Virumbrales-Muñoz, M., Ayuso, J. M., Gong, M. M., Humayun, M., Livingston, M. K., Lugo-Cintrón, K. M., McMinn, P., Álvarez-García, Y. R., & Beebe, D. J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00705f · Cited by 76
In Vitro Immune Organs-on-Chip for Drug Development: A Review
Shanti, A., Teo, J., & Stefanini, C. (2018) · Pharmaceutics · doi:10.3390/pharmaceutics10040278 · Cited by 65
“Lymphatic vessels Microcirculation Exchange of substances between circulatory and lymphatic system occur through lymphatic vessels therefore, models examining how pharmaceutical drugs leave bloodstream and enter into nearby afferent lymphatics are highly desirable [42]”
BackgroundA Robust Method for Perfusable Microvascular Network Formation In Vitro
Wan, Z., Zhong, A. X., Zhang, S., Pavlou, G., Coughlin, M. F., Shelton, S. E., Nguyen, H. T., Lorch, J. H., Barbie, D. A., & Kamm, R. D. (2022) · Small Methods · doi:10.1002/smtd.202200143 · Cited by 64
3D Immunocompetent Organ‐on‐a‐Chip Models
Maharjan, S., Cecen, B., & Zhang, Y. S. (2020) · Small Methods · doi:10.1002/smtd.202000235 · Cited by 62
Modeling Immunity In Vitro: Slices, Chips, and Engineered Tissues
Hammel, J. H., Cook, S. R., Belanger, M. C., Munson, J. M., & Pompano, R. R. (2021) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-082420-124920 · Cited by 64
“This reduced tightness of the cell–cell junctions of both the BECs and the LECs, leading to an increase in vascular permeability (176).”
Vessel-on-a-chip models for studying microvascular physiology, transport, and function in vitro
Moses, S. R., Adorno, J. J., Palmer, A. F., & Song, J. W. (2020) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00355.2020 · Cited by 80
“are not limited to sprouting angiogenesis (118, 119), vessel permeability (120, 121), and tumor cell–vessel interactions”
BackgroundHenderson, A. R., Choi, H., & Lee, E. (2020) · Micromachines · doi:10.3390/mi11020147 · Cited by 64
Singh, Y. P., Moses, J. C., Bhardwaj, N., & Mandal, B. B. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100961 · Cited by 57
Ebola Hemorrhagic Shock Syndrome-on-a-Chip
Junaid, A., Tang, H., van Reeuwijk, A., Abouleila, Y., Wuelfroth, P., van Duinen, V., Stam, W., van Zonneveld, A. J., Hankemeier, T., & Mashaghi, A. (2019) · iScience · doi:10.1016/j.isci.2019.100765 · Cited by 59
Emerging Roles of Mast Cells in the Regulation of Lymphatic Immuno-Physiology
Pal, S., Nath, S., Meininger, C. J., & Gashev, A. A. (2020) · Frontiers in Immunology · doi:10.3389/fimmu.2020.01234 · Cited by 57
The Biophysics of Lymphatic Transport: Engineering Tools and Immunological Consequences
O’Melia, M. J., Lund, A. W., & Thomas, S. N. (2019) · iScience · doi:10.1016/j.isci.2019.11.005 · Cited by 52
“quantify permeability across both blood and lymphatic capillaries (Sato et al., 2015).”
BackgroundMethodNizamutdinova, I. T., Dusio, G. F., Gasheva, O. Y., Skoog, H., Tobin, R. P., Peddaboina, C. S., Meininger, C. J., Zawieja, D. C., Newell‐Rogers, M. K., & Gashev, A. A. (2016) · Aging · doi:10.18632/aging.101113 · Cited by 49
Endothelial monolayer permeability under controlled oxygen tension
Funamoto, K., Yoshino, D., Matsubara, K., Zervantonakis, I. K., Funamoto, K., NAKAYAMA, M., Masamune, J., Kimura, Y., & Kamm, R. D. (2017) · Integrative Biology · doi:10.1039/c7ib00068e · Cited by 54
Biomimetic channel modeling local vascular dynamics of pro-inflammatory endothelial changes
Thomas, A., Daniel Ou-Yang, H., Lowe-Krentz, L., Muzykantov, V. R., & Liu, Y. (2016) · Biomicrofluidics · doi:10.1063/1.4936672 · Cited by 46
Engineering approaches for cardiac organoid formation and their characterization
Joddar, B., Natividad-Diaz, S. L., Padilla, A. E., Esparza, A., Ramirez, S. P., Chambers, D. R., & Ibaroudene, H. (2022) · Translational research · doi:10.1016/j.trsl.2022.08.009 · Cited by 51
Sato, K., Nitta, M., & Ogawa, A. (2018) · Inventions · doi:10.3390/inventions4010001 · Cited by 45
Self-citationRecent Advances in Drug Delivery System Fabricated by Microfluidics for Disease Therapy
Jia, F., Gao, Y., & Wang, H. (2022) · Bioengineering · doi:10.3390/bioengineering9110625 · Cited by 43
Recent Progress in the Development of Microfluidic Vascular Models
Sato, K., & Sato, K. (2018) · Analytical Sciences · doi:10.2116/analsci.17r006 · Cited by 41
Self-citationCancer Metastasis‐on‐a‐Chip for Modeling Metastatic Cascade and Drug Screening
Brooks, A., Zhang, Y., Chen, J., & Zhao, C. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202302436 · Cited by 44
Frenkel, N. C., Poghosyan, S., Alarcon, C. R., García, S. B., Queiroz, K. C. S., van den Bent, L., Laoukili, J., Rinkes, I. H. M. B., Vulto, P., Kranenburg, O., et al. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c01378 · Cited by 43
Lymphatic Vessel on a Chip with Capability for Exposure to Cyclic Fluidic Flow
Fathi, P., Holland, G. E., Pan, D., & Esch, M. B. (2020) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c00609 · Cited by 35
Shou, Y., Johnson, S. C., Quek, Y. J., Li, X., & Tay, A. K. P. (2022) · Materials Today Bio · doi:10.1016/j.mtbio.2022.100269 · Cited by 35
Selahi, A., Fernando, T., Chakraborty, S., Muthuchamy, M., Zawieja, D. C., & Jain, A. (2021) · Lab on a Chip · doi:10.1039/d1lc00720c · Cited by 37
Luque‐González, M. A., Reis, R. L., Kundu, S. C., & Caballero, D. (2020) · Advanced Biosystems · doi:10.1002/adbi.202000045 · Cited by 36
Engineered fluidic systems to understand lymphatic cancer metastasis
Greenlee, J. D., & King, M. R. (2020) · Biomicrofluidics · doi:10.1063/1.5133970 · Cited by 31
Highly scalable and standardized organ-on-chip platform with TEER for biological barrier modeling
Nguyen, H.-T., Rissanen, S.-L., Peltokangas, M., Laakkonen, T., Kettunen, J., Barthod, L., Sivakumar, R., Palojärvi, A., Junttila, P., Talvitie, J., et al. (2024) · Tissue Barriers · doi:10.1080/21688370.2024.2315702 · Cited by 31
“It provides perfusion at lower flow rates, which helps to deliver nutrients and oxygen to cells, and removes waste products 13–18 .”
A novel porous media-based approach to outflow boundary resistances of 1D arterial blood flow models
Coccarelli, A., Prakash, A. K., & Nithiarasu, P. (2019) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-019-01122-8 · Cited by 29
Wu, Y., Fortunato, G. M., Okesola, B. O., di Brocchetti, F. L. P., Suntornnond, R., Connelly, J. T., Maria, C. D., Rodríguez‐Cabello, J. C., Vozzi, G., Wang, W., et al. (2021) · Biofabrication · doi:10.1088/1758-5090/abe4c3 · Cited by 34
“4× 10−6cm s−1) [36], an hUVECcontaining Transwell (∼5 × 10−6 cm s−1) [37], and organ-on-chip devices of the blood-brain-barrier (∼5× 10−5 cm s−1) [38].”
Central conducting lymphatic anomaly: from bench to bedside
Torales, L. D. G., Sempowski, B. A., Krikorian, G. L., Woodis, K. M., Paulissen, S. M., Smith, C. L., & Sheppard, S. E. (2024) · Journal of Clinical Investigation · doi:10.1172/jci172839 · Cited by 30
“More-advanced techniques such as “organ on a chip” will allow for affected-individual specific cellular models that can mimic in vivo assays (102–104).”
Microfluidic devices for studying coagulation biology
Trevisan, B., Porada, C. D., Atala, A., & Almeida-Porada, G. D. (2020) · Seminars in Cell and Developmental Biology · doi:10.1016/j.semcdb.2020.06.002 · Cited by 26
“This platform also reproduced the perturbations in endothelial permeability that are known to occur in response to various chemical stimuli [92].”
BackgroundGo with the flow: modeling unique biological flows in engineered in vitro platforms
Wasson, E. M., Dubbin, K., & Moya, M. L. (2021) · Lab on a Chip · doi:10.1039/d1lc00014d · Cited by 29
Relationship between G proteins coupled receptors and tight junctions
González‐Mariscal, L., Raya‐Sandino, A., González-González, L., & Hernández-Guzmán, C. (2018) · Tissue Barriers · doi:10.1080/21688370.2017.1414015 · Cited by 30
Modeling 3D Human Tumor Lymphatic Vessel Network Using High‐Throughput Platform
Lee, S., Kang, H., Park, D., Yu, J., Koh, S. K., Cho, D., Kim, D., Kang, K., & Jeon, N. L. (2021) · Advanced Biology · doi:10.1002/adbi.202000195 · Cited by 33
Endothelial Protrusions in Junctional Integrity and Barrier Function
Alves, N. G., Motawe, Z. Y., Yuan, S. Y., & Breslin, J. W. (2018) · Current topics in membranes · doi:10.1016/bs.ctm.2018.08.006 · Cited by 29
“Microfluidic membrane chip methodology has been applied by other studies targeting blood and lymphatic permeability (Srigunapalan et al., 2011; Sato et al., 2015; Thomas et al., 2017).”
MethodHarnessing Biomaterials and the Lymphatic System for ImmunomodulationPreprint
Alderfer, L., Hall, E., & Hanjaya‐Putra, D. (2020) · SSRN Electronic Journal · doi:10.1016/j.actbio.2021.06.006 · Cited by 26
Aged Lymphatic Vessels and Mast Cells in Perilymphatic Tissues
Pal, S., Meininger, C. J., & Gashev, A. A. (2017) · International Journal of Molecular Sciences · doi:10.3390/ijms18050965 · Cited by 24
Miura, T., & Yokokawa, R. (2016) · Development Growth & Differentiation · doi:10.1111/dgd.12292 · Cited by 25
“tions (Sato et al. 2015) and the maintenance of liver”
MethodMicrofabricated Physiological Models for In Vitro Drug Screening Applications
Ugolini, G. S., Cruz‐Moreira, D., Visone, R., Redaelli, A. C. L., & Rasponi, M. (2016) · Micromachines · doi:10.3390/mi7120233 · Cited by 25
“[110] aspired for a more complete model and developed a highly biomimetic”
BackgroundMicrofluidics for Angiogenesis Research
Costa, L., Reis, R. L., Silva‐Correia, J., & Oliveira, J. M. (2020) · Advances in experimental medicine and biology · doi:10.1007/978-3-030-36588-2_7 · Cited by 25
Microfluidic techniques for mechanical measurements of biological samples
Salipante, P. F. (2023) · Biophysics Reviews · doi:10.1063/5.0130762 · Cited by 27
Rhyou, J., Youn, J., Eom, S., & Kim, D. S. (2021) · ACS Macro Letters · doi:10.1021/acsmacrolett.1c00256 · Cited by 26
Bazban‐Shotorbani, S., Khare, H. A., Kajtez, J., Basak, S., Lee, J., & Kamaly, N. (2021) · ACS Applied Nano Materials · doi:10.1021/acsanm.1c00397 · Cited by 20
Lymphatic Senescence: Current Updates and Perspectives
Filelfi, S. L., Onorato, A., Brix, B., & Goswami, N. (2021) · Biology · doi:10.3390/biology10040293 · Cited by 24
“For these reasons, it is believed that histamine has an important role in inflammatory activities in perilymphatic tissues [46].”
BackgroundVersatile Vessel-on-a-Chip Platform for Studying Key Features of Blood Vascular Tumors
Llenas, M., Paoli, R., Feiner‐Gracia, N., Albertazzi, L., Samitier, J., & Caballero, D. (2021) · Bioengineering · doi:10.3390/bioengineering8060081 · Cited by 23
Trapečar, M. (2021) · FEBS Letters · doi:10.1002/1873-3468.14260 · Cited by 22
Lacombe, J., Soldevila, M., & Zenhausern, F. (2022) · Progress in molecular biology and translational science · doi:10.1016/bs.pmbts.2021.07.019 · Cited by 25
Microphysiological systems: analysis of the current status, challenges and commercial future
Ribas, J., Pawlikowska, J., & Rouwkema, J. (2018) · Microphysiological Systems · doi:10.21037/mps.2018.10.01 · Cited by 23
Lim, J., Fang, H., Bupphathong, S., Sung, P.-C., Yeh, C.-E., Huang, W. R., & Lin, C.-H. (2024) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.3c01978 · Cited by 25
Carvalho, M. R., Maia, F. R., Silva‐Correia, J., Costa, B. M., Reis, R. L., & Oliveira, J. M. (2017) · Nanomedicine · doi:10.2217/nnm-2016-0344 · Cited by 21
In Vitro Models of Blood and Lymphatic Vessels—Connecting Tissues and Immunity
Bogseth, A., Ramirez, A., Vaughan, E., & Maisel, K. (2022) · Advanced Biology · doi:10.1002/adbi.202200041 · Cited by 20
Influence of Culture Conditions on Cell Proliferation in a Microfluidic Channel
Sato, K., Sato, M., Yokoyama, M., Hirai, M., & Furuta, A. (2018) · Analytical Sciences · doi:10.2116/analsci.18sdp04 · Cited by 17
Self-citationApplication of microscale culture technologies for studying lymphatic vessel biology
Chang, C.-S., Seibel, A. J., & Song, J. W. (2019) · Microcirculation · doi:10.1111/micc.12547 · Cited by 17
Fabrication of a Gelatin-Based Microdevice for Vascular Cell Culture
Sasaki, S., Suzuki, T., Morikawa, K., Matsusaki, M., & Sato, K. (2022) · Micromachines · doi:10.3390/mi14010107 · Cited by 21
Self-citationMimicking blood and lymphatic vasculatures using microfluidic systems
Hall, E., Mendiola, K., Lightsey, N. K., & Hanjaya‐Putra, D. (2024) · Biomicrofluidics · doi:10.1063/5.0175154 · Cited by 20
Modeling lymphangiogenesis: Pairing in vitro and in vivo metrics
Suarez, A. C., Hammel, J. H., & Munson, J. M. (2023) · Microcirculation · doi:10.1111/micc.12802 · Cited by 20
Building Blood Vessel Chips with Enhanced Physiological Relevance
Mu, X., Gerhard‐Herman, M. D., & Zhang, Y. S. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202201778 · Cited by 16
Stromal regulation of tumor-associated lymphatics
Munir, H., Mazzaglia, C., & Shields, J. D. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.08.001 · Cited by 15
A Microfluidic Model Artery for Studying the Mechanobiology of Endothelial Cells
Yu, H., Kang, D. W., Whang, M., Kim, T., & Kim, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100508 · Cited by 13
A biomimetic chip to assess subcutaneous bioavailability of monoclonal antibodies in humans
Suja, V. C., Qi, Q. M., Halloran, K. T., Zhang, J., Shaha, S., Prakash, S., Kumbhojkar, N., Deslandes, A., Huille, S., Gokarn, Y. R., et al. (2023) · PNAS Nexus · doi:10.1093/pnasnexus/pgad317 · Cited by 19
“Our experimental measurements of R 23 , on the order of 10 − 3 − 10 − 4 μ m/s, agree with in vivo (52, 53) and in vitro measurements (54), and confirm the formation of a physiological endothelial barrier.”
Sato, K., Nakajima, M., Tokuda, S., & Ogawa, A. (2016) · Analytical Sciences · doi:10.2116/analsci.32.1217 · Cited by 13
Self-citationSasaki, N., Tatanou, M., Suzuki, T., Anraku, Y., Kishimura, A., Kataoka, K., & Sato, K. (2016) · Analytical Sciences · doi:10.2116/analsci.32.1307 · Cited by 12
Self-citationMicrofluidic systems in cancer research
Caballero, D., Luque‐González, M. A., Reis, R. L., & Kundu, S. C. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818128-7.00015-0 · Cited by 13
Glomerular routing of tumor-derived extracellular vesicles substantiates urinary biopsy
Kawaguchi, S., Ajiri, T., Mitsuya, R., Tsuchiya, R., Kunitake, K., Tanaka, Y., Yokoyama, T., Sato, K., Sato, Y., Zhu, Z., et al. (2026) · Science Advances · doi:10.1126/sciadv.aeb0555 · Cited by 11
“S8) ( 37 ).”
Self-citationThe motion of long bubbles in microchannels using a meter-long, rectangular capillary on a chip
Nazari, N., Yun, W., & Kovscek, A. R. (2023) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2023.01.073 · Cited by 9
Gao, F., Sun, H., Li, X., & He, P. (2021) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00478.2021 · Cited by 11
Engineered models of the lymphatic vascular system: Past, present, and future
Selahi, A., & Jain, A. (2022) · Microcirculation · doi:10.1111/micc.12793 · Cited by 12
Kagawa, M., Morioka, K., Osashima, M., Hemmi, A., Yamamoto, S., Shoji, A., Uchiyama, K., & Nakajima, H. (2022) · Talanta · doi:10.1016/j.talanta.2023.124311 · Cited by 9
Mayo, L. N., & Kutys, M. L. (2022) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00173.2022 · Cited by 9
Advances and Applications of Organ-on-a-Chip and Tissue-on-a-Chip Technology
Moore, M., Sriram, S., Ku, J. C., & Li, Y. (2025) · Bioengineering · doi:10.3390/bioengineering13010009 · Cited by 10
“Vascular and lymphatic endothelial cells grown in microfluidic devices have been shown to mimic normal physiological functions by forming cell–cell junctions that increase permeability in response to histamine exposure [32].”
Sato, K., Maeda, M., Kamata, E., Ishii, S., Yanagisawa, K., Kitajima, K., & Hara, T. (2020) · Micromachines · doi:10.3390/mi11030305 · Cited by 7
“5 mm × 800 mm; Iwase, Kanagawa, Japan) via a bubble trap and fabricated as reported previously [28,29].”
MethodSelf-citationHuman Vascular Wall Microfluidic Model for Preclinical Evaluation of Drug-Induced Vascular Injury
Ersland, E., Ebrahim, N., Mwizerwa, O., Oba, T., Oku, K., Nishino, M., Hikimoto, D., Miyoshi, H., Tomotoshi, K., Rahmanian, O., et al. (2022) · Tissue Engineering Part C Methods · doi:10.1089/ten.tec.2021.0227 · Cited by 7
Bioengineered in vitro models of leukocyte–vascular interactions
Lee, J., Breuer, C. B., & Lee, E. (2021) · Biochemical Society Transactions · doi:10.1042/bst20200620 · Cited by 7
Peng, Y., & Lee, E. (2026) · Lab on a Chip · doi:10.1039/d5lc00875a · Cited by 10
Personalized Models of Biological Barriers and Their Diseases: Recent Progress with Organs‐On‐Chips
Buck, F., Bugter, J., Yorukoglu, G., Dastjerd, M. K., & Winkler, T. E. (2026) · Advanced Biology · doi:10.1002/adbi.202500536 · Cited by 10
Understanding the Lymphatic System: Tissue-on-Chip Modeling
Polacheck, W. J., Dixon, J. B., & Aw, W. Y. (2025) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110222-100246 · Cited by 9
Trends in biomaterials for three-dimensional cancer modeling
Caballero, D., Reis, R. L., & Kundu, S. C. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818128-7.00001-0 · Cited by 6
Development of a Simple Permeability Assay Method for Snake Venom-induced Vascular Damage
Sato, K., Kodama, A., Kase, C., Hirakawa, S., & Ato, M. (2018) · Analytical Sciences · doi:10.2116/analsci.34.323 · Cited by 5
Self-citationFabrication of Microfluidic Cell Culture Devices Using a Consumer Laser Cutter
SASAKI, N., Hayashi, T., INOUE, N., & Onishi, M. (2018) · BUNSEKI KAGAKU · doi:10.2116/bunsekikagaku.67.379 · Cited by 5
Self-citationLymphatic Tissue and Organ Engineering for In Vitro Modeling and In Vivo Regeneration
Kolarzyk, A. M., Wong, G., & Lee, E. (2022) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a041169 · Cited by 8
“3D; Sato et al. 2015).”
BackgroundHodges, N. A., Barr, R. W., & Murfee, W. L. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108923 · Cited by 5
Bachmann, B., Spitz, S., Jordan, C., Schuller, P., Wanzenböck, H. D., Haddadi, B., Harasek, M., Redl, H. R., Holnthoner, W., & Ertl, P. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.04.08.438936 · Cited by 7
Metadata
- Authors
- Sato, M., Sasaki, N., Ato, M., Hirakawa, S., Sato, K., & Sato, K.
- Affiliations
- Japan Women's University (JP)
- National Institute of Infectious Diseases (JP)
- Hamamatsu University School of Medicine (JP)
- Gunma University (JP)
- Corresponding author
- Sato, Kae
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-09-02
- Volume
- 10
- Issue
- 9
- Pages
- e0137301
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC4558006
- OpenAlex
- W2152239270
- Cited by
- 124
- References
- 59
- Citations by year
- 2026: 6 · 2025: 7 · 2024: 9 · 2023: 10 · 2022: 13 · 2021: 22 · 2020: 21 · 2019: 9 · 2018: 10 · 2017: 7 · 2016: 8 · 2015: 1
- FWCI
- 4.63
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- Suzuken Memorial Foundation
- Tokyo Ohka Foundation for The Promotion of Science and Technology
- Japan Society for the Promotion of Science (25600065, 24350035, 15K13719, CREST, 25293227, 15H03823)
- Core Research for Evolutional Science and Technology
- Topics
- Life Sciences › Neuroscience › Neurology › Barrier Structure and Function Studies
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Health Sciences › Medicine › Oncology › Lymphatic System and Diseases
- Keywords
- vascular permeability, lymphatic vessels, lymphatic endothelial cells, blood endothelial cells, claudin-5, VE-cadherin, tight junctions, adherens junctions, histamine, inflammation, habu snake venom, microfluidics
- MeSH terms
- Animals, Capillary Permeability, Cattle, Cells, Cultured, Endothelium, Vascular, Histamine, Humans, Microcirculation, Coculture Techniques, Lymphatic Vessels, Lab-On-A-Chip Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.