Abstract
We developed a microfluidic model of microcirculation containing both blood and lymphatic vessels for examining vascular permeability. The designed microfluidic device harbors upper and lower channels that are partly aligned and are separated by a porous membrane, and on this membrane, blood vascular endothelial cells (BECs) and lymphatic endothelial cells (LECs) were cocultured back-to-back. At cell-cell junctions of both BECs and LECs, claudin-5 and VE-cadherin were detected. The permeability coefficient measured here was lower than the value reported for isolated mammalian venules. Moreover, our results showed that the flow culture established in the device promoted the formation of endothelial cell-cell junctions, and that treatment with histamine, an inflammation-promoting substance, induced changes in the localization of tight and adherens junction-associated proteins and an increase in vascular permeability in the microdevice. These findings indicated that both BECs and LECs appeared to retain their functions in the microfluidic coculture platform. Using this microcirculation device, the vascular damage induced by habu snake venom was successfully assayed, and the assay time was reduced from 24 h to 30 min. This is the first report of a microcirculation model in which BECs and LECs were cocultured. Because the micromodel includes lymphatic vessels in addition to blood vessels, the model can be used to evaluate both vascular permeability and lymphatic return rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bertrand, N., Wu, J., Xu, X., Kamaly, N., & Farokhzad, O. C. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.11.009 · Cited by 2,824
Maeda, H., Nakamura, H., & Fang, J. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.10.002 · Cited by 2,376 · cited 1×
“Studies on drug-delivery systems (DDSs) have previously investigated the enhanced permeation and retention effect, which is caused by the presence of imperfect tumor blood vessels and poor lymphatic drainage in tumor tissues [54,55], and a lymphatic system-targeted DDS has also attracted research attention [56].”
BackgroundAngiosarcomas Express Mixed Endothelial Phenotypes of Blood and Lymphatic Capillaries
Breiteneder-Geleff, S., Soleiman, A., Kowalski, H., Horvat, R., Amann, G., Kriehuber, E., Diem, K., Weninger, W., Tschachler, E., Alitalo, K., et al. (1999) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)65285-6 · Cited by 1,090
In vitro microvessels for the study of angiogenesis and thrombosis
Zheng, Y., Chen, J., Craven, M., Choi, N. W., Totorica, S., Diaz-Santana, A., Kermani, P., Hempstead, B., Fischbach-Teschl, C., López, J. A., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201240109 · Cited by 894
Engineering of functional, perfusable 3D microvascular networks on a chip
Kim, S., Lee, H., Chung, M., & Jeon, N. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41320a · Cited by 872
Morita, K., Sasaki, H., Furuse, M., & Tsukita, S. (1999) · The Journal of Cell Biology · doi:10.1083/jcb.147.1.185 · Cited by 869
Characterization of a microfluidic in vitro model of the blood-brain barrier (μBBB)
Booth, R., & Kim, H. (2012) · Lab on a Chip · doi:10.1039/c2lc40094d · Cited by 739
STUDIES ON THE QUANTITATIVE METHOD FOR DETERMINATION OF HEMORRHAGIC ACTIVITY OF HABU SNAKE VENOM
KONDO, H., KONDO, S., IKEZAWA, H., MURATA, R., & OHSAKA, A. (1960) · Japanese Journal of Medical Science and Biology · doi:10.7883/yoken1952.13.43 · Cited by 586
Formation of perfused, functional microvascular tubes in vitro
Chrobak, K. M., Potter, D. R., & Tien, J. (2006) · Microvascular Research · doi:10.1016/j.mvr.2006.02.005 · Cited by 553
Griep, L. M., Wolbers, F., de Wagenaar, B., ter Braak, P. M., Weksler, B. B., Romero, I. A., Couraud, P. O., Vermes, I., van der Meer, A. D., & van den Berg, A. (2013) · Biomedical Microdevices · doi:10.1007/s10544-012-9699-7 · Cited by 537
Fluid forces control endothelial sprouting
Song, J. W., & Munn, L. L. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1105316108 · Cited by 498
Report of a WHO workshop on the standardization and control of antivenoms
Theakston, R. D. G., Warrell, D. A., & Griffiths, E. (2003) · Toxicon · doi:10.1016/s0041-0101(02)00393-8 · Cited by 439
Saria, A., Lundberg, J. M., Skofitsch, G., & Lembeck, F. (1983) · Naunyn-Schmiedeberg's Archives of Pharmacology · doi:10.1007/bf00503897 · Cited by 422
Molecular mechanisms of endothelial hyperpermeability: implications in inflammation
Kumar, P., Shen, Q., Pivetti, C. D., Lee, E. S., Wu, M. H., & Yuan, S. Y. (2009) · Expert Reviews in Molecular Medicine · doi:10.1017/s1462399409001112 · Cited by 380
SyM-BBB: a microfluidic blood brain barrier model
Prabhakarpandian, B., Shen, M.-C., Nichols, J. B., Mills, I. R., Sidoryk-Wegrzynowicz, M., Aschner, M., & Pant, K. (2013) · Lab on a Chip · doi:10.1039/c2lc41208j · Cited by 339
Microfluidic Endothelium for Studying the Intravascular Adhesion of Metastatic Breast Cancer Cells
Song, J. W., Cavnar, S. P., Walker, A. C., Luker, K. E., Gupta, M., Tung, Y.-C., Luker, G. D., & Takayama, S. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005756 · Cited by 317
Mechanisms of tumor cell extravasation in an in vitro microvascular network platform
Chen, M. B., Whisler, J. A., Jeon, J. S., & Kamm, R. D. (2013) · Integrative Biology · doi:10.1039/c3ib40149a · Cited by 308 · cited 2×
“In these previous studies, the culture periods were much longer (4 d [45], 6–7 d [46], or 14 d [44]) than the present work (24 h).”
VE-cadherin: at the front, center, and sides of endothelial cell organization and function
Harris, E. S., & Nelson, W. J. (2010) · Current Opinion in Cell Biology · doi:10.1016/j.ceb.2010.07.006 · Cited by 291
Inflammation and the Microcirculation
Granger, D. N., & Senchenkova, E. Y. (2010) · Colloquium Series on Integrated Systems Physiology From Molecule to Function · doi:10.4199/c00013ed1v01y201006isp008 · Cited by 282
Amerongen, G. P. V. N., Draijer, R., Vermeer, M. A., & van Hinsbergh, V. W. M. (1998) · Circulation Research · doi:10.1161/01.res.83.11.1115 · Cited by 270
Lymph Flow, Shear Stress, and Lymphocyte Velocity in Rat Mesenteric Prenodal Lymphatics
DIXON, J. B., GREINER, S. T., GASHEV, A. A., COTE, G. L., MOORE, J. E., & ZAWIEJA, D. C. (2006) · Microcirculation · doi:10.1080/10739680600893909 · Cited by 267
Modelling the lymphatic system: challenges and opportunities
Margaris, K. N., & Black, R. A. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0751 · Cited by 229
Leakage-Free Bonding of Porous Membranes into Layered Microfluidic Array Systems
Chueh, B.-H., Huh, D., Kyrtsos, C. R., Houssin, T., Futai, N., & Takayama, S. (2007) · Analytical Chemistry · doi:10.1021/ac062118p · Cited by 207
Yeon, J. H., Ryu, H. R., Chung, M., Hu, Q. P., & Jeon, N. L. (2012) · Lab on a Chip · doi:10.1039/c2lc40131b · Cited by 179
Chen, M. B., Srigunapalan, S., Wheeler, A. R., & Simmons, C. A. (2013) · Lab on a Chip · doi:10.1039/c3lc00051f · Cited by 179
A microfluidic system to evaluate intestinal absorption
Imura, Y., Asano, Y., Sato, K., & Yoshimura, E. (2009) · Analytical Sciences · doi:10.2116/analsci.25.1403 · Cited by 159 · cited 1×
“The bubble trap was fabricated in accordance with published details [36] and was composed of 2 TYGON tubes of dimensions 0.”
MethodSelf-citationInstitute for Clinical and Experimental Surgery, U. O. S., Laschke, M., Vollmar, & Menger, M. (2011) · European Cells and Materials · doi:10.22203/ecm.v022a12 · Cited by 155
Booth, R., & Kim, H. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1086-5 · Cited by 132
Rigor, R. R., Shen, Q., Pivetti, C. D., Wu, M. H., & Yuan, S. Y. (2013) · Medicinal Research Reviews · doi:10.1002/med.21270 · Cited by 130
Kano, M. R., Komuta, Y., Iwata, C., Oka, M., Shirai, Y., Morishita, Y., Ouchi, Y., Kataoka, K., & Miyazono, K. (2009) · Cancer Science · doi:10.1111/j.1349-7006.2008.01003.x · Cited by 121
‘Go with the flow ’: A review of methods and advancements in blood flow imaging
Daly, S. M., & Leahy, M. J. (2013) · Journal of Biophotonics · doi:10.1002/jbio.201200071 · Cited by 115
van der Meer, A. D., Poot, A. A., Feijen, J., & Vermes, I. (2010) · Biomicrofluidics · doi:10.1063/1.3366720 · Cited by 108
Young, E. W. K., Watson, M. W. L., Srigunapalan, S., Wheeler, A. R., & Simmons, C. A. (2010) · Analytical Chemistry · doi:10.1021/ac901560w · Cited by 102
A BODIPY Fluorescent Microplate Assay for Measuring Activity of Calpains and Other Proteases
Thompson, V. F., Saldãna, S., Cong, J., & Goll, D. E. (2000) · Analytical Biochemistry · doi:10.1006/abio.1999.4475 · Cited by 101
Recent advances in lymphatic targeted drug delivery system for tumor metastasis.
Zhang, X.-Y., & Lu, W. (2014) · PubMed Central · doi:10.7497/j.issn.2095-3941.2014.04.003 · Cited by 100
A bioengineered array of 3D microvessels for vascular permeability assay
Lee, H., Kim, S., Chung, M., Kim, J. H., & Jeon, N. L. (2013) · Microvascular Research · doi:10.1016/j.mvr.2013.12.001 · Cited by 95
VE-cadherin and β-catenin binding dynamics during histamine-induced endothelial hyperpermeability
Guo, M., Breslin, J. W., Wu, M. H., Gottardi, C. J., & Yuan, S. Y. (2008) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.90607.2007 · Cited by 89
Effect of cyclic AMP on barrier function of human lymphatic microvascular tubes
Price, G. M., Chrobak, K. M., & Tien, J. (2008) · Microvascular Research · doi:10.1016/j.mvr.2008.02.003 · Cited by 80 · cited 1×
“By contrast, only 2 reports have been published on a lymphatic vascular model, in which the permeation assay was performed with lymphatic flow effects [32,33].”
BackgroundWu, M. H., Ustinova, E., & Granger, H. J. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.0785e.x · Cited by 76
Artificial lymphatic drainage systems for vascularized microfluidic scaffolds
Wong, K. H. K., Truslow, J. G., Khankhel, A. H., Chan, K. L. S., & Tien, J. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34524 · Cited by 74
Lymphedema and Therapeutic Lymphangiogenesis
Saito, Y., Nakagami, H., Kaneda, Y., & Morishita, R. (2013) · BioMed Research International · doi:10.1155/2013/804675 · Cited by 69
A microfluidic membrane device to mimic critical components of the vascular microenvironment
Srigunapalan, S., Lam, C., Wheeler, A. R., & Simmons, C. A. (2011) · Biomicrofluidics · doi:10.1063/1.3530598 · Cited by 67
Kawai, Y., Yokoyama, Y., Kaidoh, M., & Ohhashi, T. (2009) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00249.2009 · Cited by 62
Recent advances in lymphatic targeted drug delivery system for tumor metastasis
Xiaoyu, Zhang, Z., Wei-yue, & Lu, L. (2014) · 癌症生物学与医学:英文版 · Cited by 61
Crosslinking of collagen scaffolds promotes blood and lymphatic vascular stability
Chan, K. L. S., Khankhel, A. H., Thompson, R. L., Coisman, B. J., Wong, K. H. K., Truslow, J. G., & Tien, J. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34990 · Cited by 59
Lymphatic Endothelial Cells Adapt Their Barrier Function in Response to Changes in Shear Stress
Breslin, J. W., & Kurtz, K. M. (2009) · Lymphatic Research and Biology · doi:10.1089/lrb.2009.0015 · Cited by 54
Culture and Leukocyte Adhesion Assay of Human Arterial Endothelial Cells in a Glass Microchip
Tanaka, Y., Kikukawa, Y., Sato, K., Sugii, Y., & Kitamori, T. (2007) · Analytical Sciences · doi:10.2116/analsci.23.261 · Cited by 51
Self-citationFarmer, P. J., Bernier, S. G., Lepage, A., Guillemette, G., Regoli, D. C., & Sirois, P. (2001) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.2001.280.4.l732 · Cited by 50
Tsuji, T., Sasaki, Y., Tanaka, M., Hanabata, N., Hada, R., & Munakata, A. (2002) · Laboratory Investigation · doi:10.1038/labinvest.3780450 · Cited by 46
A palmtop‐sized microfluidic cell culture system driven by a miniaturized infusion pump
Sasaki, N., Shinjo, M., Hirakawa, S., Nishinaka, M., Tanaka, Y., Mawatari, K., Kitamori, T., & Sato, K. (2012) · Electrophoresis · doi:10.1002/elps.201100691 · Cited by 45
Self-citationOno, N., Mizuno, R., & Ohhashi, T. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01084.2004 · Cited by 42
A microfluidic chip for permeability assays of endothelial monolayer
Shao, J., Wu, L., Wu, J., Zheng, Y., Zhao, H., Lou, X., Jin, Q., & Zhao, J. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9362-0 · Cited by 31
Probing single cells using flow in microfluidic devices
Qi, D., Hoelzle, D. J., & Rowat, A. C. (2012) · The European Physical Journal Special Topics · doi:10.1140/epjst/e2012-01554-x · Cited by 29
Reed, A. L., Rowson, S. A., & Dixon, J. B. (2013) · Pharmaceutical Research · doi:10.1007/s11095-013-1218-x · Cited by 26
Morine, N., Matsuda, S., Terada, K., Eto, A., Ishida, I., & Oku, H. (2007) · Toxicon · doi:10.1016/j.toxicon.2007.10.009 · Cited by 19
Synergistic Effect of Histamine and TNF-α on Monocyte Adhesion to Vascular Endothelial Cells
Chen, C., & Khismatullin, D. B. (2012) · Inflammation · doi:10.1007/s10753-012-9548-0 · Cited by 18
(2012) · Lab on a Chip · doi:10.1039/c2lc90132c · Cited by 12
Characterization of nanoparticle permeability on a membrane-integrated microfluidic device
Sasaki, N., Tatanou, M., Anraku, Y., Kishimura, A., Kataoka, K., & Sato, K. (2013) · Cited by 1
Self-citation
Cited by
Microfluidic Model Porous Media: Fabrication and Applications
Anbari, A., Chien, H., Datta, S. S., Deng, W., Weitz, D. A., & Fan, J. (2018) · Small · doi:10.1002/smll.201703575 · Cited by 248
Microfluidic modelling of the tumor microenvironment for anti-cancer drug development
Shang, M., Soon, R. H., Lim, C. T., Khoo, B. L., & Han, J. (2019) · Lab on a Chip · doi:10.1039/c8lc00970h · Cited by 227
Azizgolshani, H., Coppeta, J. R., Vedula, E. M., Marr, E. E., Cain, B. P., Luu, R. J., Lech, M. P., Kann, S. H., Mulhern, T. J., Tandon, V., et al. (2021) · Lab on a Chip · doi:10.1039/d1lc00067e · Cited by 225
Organ-on-chip models of cancer metastasis for future personalized medicine: From chip to the patient
Caballero, D., Kaushik, S., Correlo, V. M., Oliveira, J. M., Reis, R. L., & Kundu, S. C. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.005 · Cited by 221
Mechanisms of Nanoparticle Transport across Intestinal Tissue: An Oral Delivery Perspective
Ejazi, S. A., Louisthelmy, R., & Maisel, K. (2023) · ACS Nano · doi:10.1021/acsnano.3c02403 · Cited by 210
Metadata
- Authors
- Sato, M., Sasaki, N., Ato, M., Hirakawa, S., Sato, K., & Sato, K.
- Affiliations
- Japan Women's University (JP)
- National Institute of Infectious Diseases (JP)
- Hamamatsu University School of Medicine (JP)
- Gunma University (JP)
- Corresponding author
- Sato, Kae
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-09-02
- Volume
- 10
- Issue
- 9
- Pages
- e0137301
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC4558006
- OpenAlex
- W2152239270
- Cited by
- 124
- References
- 59
- Citations by year
- 2026: 6 · 2025: 7 · 2024: 9 · 2023: 10 · 2022: 13 · 2021: 22 · 2020: 21 · 2019: 9 · 2018: 10 · 2017: 7 · 2016: 8 · 2015: 1
- FWCI
- 4.63
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- Suzuken Memorial Foundation
- Tokyo Ohka Foundation for The Promotion of Science and Technology
- Japan Society for the Promotion of Science (25600065, 24350035, 15K13719, CREST, 25293227, 15H03823)
- Core Research for Evolutional Science and Technology
- Topics
- Life Sciences › Neuroscience › Neurology › Barrier Structure and Function Studies
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Health Sciences › Medicine › Oncology › Lymphatic System and Diseases
- Keywords
- vascular permeability, lymphatic vessels, lymphatic endothelial cells, blood endothelial cells, claudin-5, VE-cadherin, tight junctions, adherens junctions, histamine, inflammation, habu snake venom, microfluidics
- MeSH terms
- Animals, Capillary Permeability, Cattle, Cells, Cultured, Endothelium, Vascular, Histamine, Humans, Microcirculation, Coculture Techniques, Lymphatic Vessels, Lab-On-A-Chip Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.