CoChat

A Novel Algorithm for Movement Artifact Removal in ECG Signals Acquired from Wearable Systems Applied to Horses

Open access

The DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.

Abstract

This study reports on a novel method to detect and reduce the contribution of movement artifact (MA) in electrocardiogram (ECG) recordings gathered from horses in free movement conditions. We propose a model that integrates cardiovascular and movement information to estimate the MA contribution. Specifically, ECG and physical activity are continuously acquired from seven horses through a wearable system. Such a system employs completely integrated textile electrodes to monitor ECG and is also equipped with a triaxial accelerometer for movement monitoring. In the literature, the most used technique to remove movement artifacts, when noise bandwidth overlaps the primary source bandwidth, is the adaptive filter. In this study we propose a new algorithm, hereinafter called Stationary Wavelet Movement Artifact Reduction (SWMAR), where the Stationary Wavelet Transform (SWT) decomposition algorithm is employed to identify and remove movement artifacts from ECG signals in horses. A comparative analysis with the Normalized Least Mean Square Adaptive Filter technique (NLMSAF) is performed as well. Results achieved on seven hours of recordings showed a reduction greater than 40% of MA percentage (between before- and after- the application of the proposed algorithm). Moreover, the comparative analysis with the NLMSAF, applied to the same ECG recordings, showed a greater reduction of MA percentage in favour of SWMAR with a statistical significant difference (p-value < 0.0.5).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0140783

Cites

72 of 72 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig 1 Scheme of the electronic set up: placement of the proposed system.
Fig 1 Scheme of the electronic set up: placement of the proposed system.CC BY · PubMed Central
Fig 2 Block diagram of the proposed method. After a pre-processing phase, the SWT decomposition, the QRS complexes and motion detections are performed followed by the reconstruction of the signal affected by artifacts, that is used to reduce and/or remove MAs.
Fig 2 Block diagram of the proposed method. After a pre-processing phase, the SWT decomposition, the QRS complexes and motion detections are performed followed by the reconstruction of the signal affected by artifacts, that is used to reduce and/or remove MAs.CC BY · PubMed Central
Fig 3 Block diagram of the QRS-complexes detection. The method employes a threshold to detect QRS complexes based on an estimate of the energy of the second derivative of the ECG signals.
Fig 3 Block diagram of the QRS-complexes detection. The method employes a threshold to detect QRS complexes based on an estimate of the energy of the second derivative of the ECG signals.CC BY · PubMed Central
Fig 4 Example of two consecutive QRS complexes detected by the proposed method. Letter A indicates the stating time-instant while B indicates the ending time-instant.
Fig 4 Example of two consecutive QRS complexes detected by the proposed method. Letter A indicates the stating time-instant while B indicates the ending time-instant.CC BY · PubMed Central
Fig 5 Block diagram of the Motion-detection procedure. After the signal is rectified and subtracted by its mean value, strong movement segments are detected through a threshold as estimated in Eq (2). These motion signal segments can introduce MAs.
Fig 5 Block diagram of the Motion-detection procedure. After the signal is rectified and subtracted by its mean value, strong movement segments are detected through a threshold as estimated in Eq (2). These motion signal segments can introduce MAs.CC BY · PubMed Central
Fig 6 The graph at the top shows the acceleration module with an event of remarkable movement, while at the bottom the ECG with the corresponding MA is reported.
Fig 6 The graph at the top shows the acceleration module with an event of remarkable movement, while at the bottom the ECG with the corresponding MA is reported.CC BY · PubMed Central
Fig 7 Histograms of the distribution of maxima (right) and minima (left) for a given decomposition level. In red the relative thresholds are displayed.
Fig 7 Histograms of the distribution of maxima (right) and minima (left) for a given decomposition level. In red the relative thresholds are displayed.CC BY · PubMed Central
Fig 8 Recursive scheme of an Adaptive filter.
Fig 8 Recursive scheme of an Adaptive filter.CC BY · PubMed Central
Fig 9 Bland-Altman plot comparing QRS complex starting time instant series between the SWMAR algorithm with those provided by PhysioNet Database. The black line indicates the bias (mean difference), the red lines are limits of agreement (mean ± 2 SD), whilst the blue line indicates the trend of the data. Mean = −0.0204 (95% CI: −0.0195 to −0.0213); limits of agreement between 0.0036 and −0.0372.
Fig 9 Bland-Altman plot comparing QRS complex starting time instant series between the SWMAR algorithm with those provided by PhysioNet Database. The black line indicates the bias (mean difference), the red lines are limits of agreement (mean ± 2 SD), whilst the blue line indicates the trend of the data. Mean = −0.0204 (95% CI: −0.0195 to −0.0213); limits of agreement between 0.0036 and −0.0372.CC BY · PubMed Central
Fig 10 Bland-Altman plot comparing QRS complex ending time instant series between the SWMAR algorithm with those provided by PhysioNet Database. The black line indicates the bias (mean difference), the red lines are limits of agreement (mean ± 2 SD), whilst the blue line indicates the trend of the data. Mean = 0.0105 (95% CI: 0.0115 to 0.0094); limits of agreement between −0.0309 and −0.0099.
Fig 10 Bland-Altman plot comparing QRS complex ending time instant series between the SWMAR algorithm with those provided by PhysioNet Database. The black line indicates the bias (mean difference), the red lines are limits of agreement (mean ± 2 SD), whilst the blue line indicates the trend of the data. Mean = 0.0105 (95% CI: 0.0115 to 0.0094); limits of agreement between −0.0309 and −0.0099.CC BY · PubMed Central
Fig 11 Decomposition of a clean ECG segment. At the top the original ECG signal is plotted, following the 5 decomposition detail signals and the approximation regarding the 5th level. Red and yellow lines represent the threshold levels as calculated according to Eqs (19) and (20).
Fig 11 Decomposition of a clean ECG segment. At the top the original ECG signal is plotted, following the 5 decomposition detail signals and the approximation regarding the 5th level. Red and yellow lines represent the threshold levels as calculated according to Eqs (19) and (20).CC BY · PubMed Central
Fig 12 Decomposition of an ECG segment affected by artifacts. At the top the original ECG signal is plotted, following the 5 decomposition detail signals and the approximation regarding the 5th level. Red and yellow lines represent the threshold levels as calculated according to Eqs (19) and (20). The figure shows that MAs details and approximations coefficients that are out of the interval delimited by the two thresholds.
Fig 12 Decomposition of an ECG segment affected by artifacts. At the top the original ECG signal is plotted, following the 5 decomposition detail signals and the approximation regarding the 5th level. Red and yellow lines represent the threshold levels as calculated according to Eqs (19) and (20). The figure shows that MAs details and approximations coefficients that are out of the interval delimited by the two thresholds.CC BY · PubMed Central
Fig 13 The upper plot reports the accelerometric signal (in red) along with the ECG signal with the corresponding artifact. The lower plot shows the ECG signal after applying the MA removal algorithm.
Fig 13 The upper plot reports the accelerometric signal (in red) along with the ECG signal with the corresponding artifact. The lower plot shows the ECG signal after applying the MA removal algorithm.CC BY · PubMed Central
Fig 14 Boxplot of the MAs percentage before and after the method of removal MAs.
Fig 14 Boxplot of the MAs percentage before and after the method of removal MAs.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 72 references

Research works printed but not linked: 3

  1. Thakor N, Webster J. The origin of skin potential and its variations. In: Proc. Ann. Conf. Eng. Biol. Med. vol. 20; 1978. p. 212.
  2. Petersen E, et al. Prevalence of arrhythmias during and immediately after racing in Standardbred trotters–is there an association between arrhythmias and myocardial hypertrophy. In: Proceedings of the BEVA Congress, Liverpool, United Kingdom; 2008. p. 138.
  3. S Li, 2009, Computer Science and Information Engineering, 2009 WRI World Congress on. vol. 6, 469

Cited by

See all 42

Metadata

Authors
Lanata, A., Guidi, A., Baragli, P., Valenza, G., & Scilingo, E. P.
Affiliations
University of Pisa (IT)
Venue
PLOS ONE
Published
2015-10-20
Volume
10
Issue
10
Pages
e0140783
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2100756879
Cited by
42
References
72
Citations by year
2026: 1 · 2025: 4 · 2024: 1 · 2023: 5 · 2022: 4 · 2021: 2 · 2020: 4 · 2019: 6 · 2018: 4 · 2017: 6 · 2016: 4
FWCI
3.40
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Florence Research (University of Florence) (submittedVersion, other-oa)
  • RePEc: Research Papers in Economics (submittedVersion)
  • CINECA IRIS Institutial research information system (University of Pisa) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
ECG denoising, horses, wearable ECG monitoring, stationary wavelet transform, adaptive filtering, triaxial accelerometer, textile electrodes, equine electrocardiography
MeSH terms
Algorithms, Animals, Electrocardiography, Horses, Movement, Signal Processing, Computer-Assisted, Artifacts, Wavelet Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Novel Algorithm for Movement Artifact Removal in ECG Signals Acquired from Wearable Systems Applied to Horses. https://app.cochat.ai/papers/10.1371/journal.pone.0140783
The paper
Lanata, A., Guidi, A., Baragli, P., Valenza, G., & Scilingo, E. P. (2015). A Novel Algorithm for Movement Artifact Removal in ECG Signals Acquired from Wearable Systems Applied to Horses. PLOS ONE. https://doi.org/10.1371/journal.pone.0140783

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.