A Novel Algorithm for Movement Artifact Removal in ECG Signals Acquired from Wearable Systems Applied to Horses
Open accessThe DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Abstract
This study reports on a novel method to detect and reduce the contribution of movement artifact (MA) in electrocardiogram (ECG) recordings gathered from horses in free movement conditions. We propose a model that integrates cardiovascular and movement information to estimate the MA contribution. Specifically, ECG and physical activity are continuously acquired from seven horses through a wearable system. Such a system employs completely integrated textile electrodes to monitor ECG and is also equipped with a triaxial accelerometer for movement monitoring. In the literature, the most used technique to remove movement artifacts, when noise bandwidth overlaps the primary source bandwidth, is the adaptive filter. In this study we propose a new algorithm, hereinafter called Stationary Wavelet Movement Artifact Reduction (SWMAR), where the Stationary Wavelet Transform (SWT) decomposition algorithm is employed to identify and remove movement artifacts from ECG signals in horses. A comparative analysis with the Normalized Least Mean Square Adaptive Filter technique (NLMSAF) is performed as well. Results achieved on seven hours of recordings showed a reduction greater than 40% of MA percentage (between before- and after- the application of the proposed algorithm). Moreover, the comparative analysis with the NLMSAF, applied to the same ECG recordings, showed a greater reduction of MA percentage in favour of SWMAR with a statistical significant difference (p-value < 0.0.5).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures














Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“By using additional sensors, such as triaxial accelerometers and gyroscopes, to synchronously monitor the movement, many methods have been proposed to detect and suppress the motion artifacts superimposed on MCG (ECG) signals, such as the adaptive filters (46) and the stationary wavelet transform (47, 48).”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [47]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A theory for multiresolution signal decomposition: the wavelet representation
Mallat, S. G. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.192463 · Cited by 21,372 · cited 1×
“[67], the signal was decomposed into various resolution levels.”
BackgroundGoldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939 · cited 1×
“It uses a “primary” input containing the corrupted signal (signal with artifacts) and a “reference” input containing artifacts correlated in some unknown way with the primary noise [30].”
MethodComparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,847
Robust Statistics: Theory and Methods
Maronna, R. A., Martin, R. D., & Yohai, V. J. (2006) · Wiley Series in Probability and Statistics · doi:10.1002/0470010940 · Cited by 1,655
A Wavelet-Based ECG Delineator: Evaluation on Standard Databases
Martinez, J. P., Almeida, R., Olmos, S., Rocha, A. P., & Laguna, P. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821031 · Cited by 1,605 · cited 1×
“In order to test the performance of the QRS detection algorithm proposed here, 19 ECG records (Fs = 250Hz) gathered from the human QT database [61, 62] provided by PhysioNet [63] (PN-DB) were used.”
MethodApplications of adaptive filtering to ECG analysis: noise cancellation and arrhythmia detection
Thakor, N. V., & Zhu, Y.-S. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83591 · Cited by 885 · cited 2×
“Successive implementations were then improved with the introduction of recursivity [31].”
BackgroundMethodA Real-Time Algorithm for Signal Analysis with the Help of the Wavelet Transform
Holschneider, M., Kronland-Martinet, R., Morlet, J., & Tchamitchian, P. (1989) · Inverse Problems and Theoretical Imaging · doi:10.1007/978-3-642-97177-8_28 · Cited by 633
Research works printed but not linked: 3
- Thakor N, Webster J. The origin of skin potential and its variations. In: Proc. Ann. Conf. Eng. Biol. Med. vol. 20; 1978. p. 212.
- Petersen E, et al. Prevalence of arrhythmias during and immediately after racing in Standardbred trotters–is there an association between arrhythmias and myocardial hypertrophy. In: Proceedings of the BEVA Congress, Liverpool, United Kingdom; 2008. p. 138.
- S Li, 2009, Computer Science and Information Engineering, 2009 WRI World Congress on. vol. 6, 469
Cited by
Toward a new generation of smart skins
Someya, T., & Amagai, M. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0079-1 · Cited by 474
Wearable Smart Textiles for Long-Term Electrocardiography Monitoring—A Review
Nigusse, A. B., Mengistie, D. A., Malengier, B., Tseghai, G. B., & Langenhove, L. V. (2021) · Sensors · doi:10.3390/s21124174 · Cited by 184
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
“…sensors, such as triaxial accelerometers and gyroscopes, to synchronously monitor the movement, many methods have been proposed to detect and suppress the motion artifacts superimposed on MCG (ECG) signals, such as the adaptive filters ( 46 ) and the stationary wavelet transform ( 47 , 48 ).”
Appathurai, A., Carol, J. J., Raja, C., Kumar, S. N., Daniel, A. V., Malar, A. J. G., Fred, A. L., & Krishnamoorthy, S. (2019) · Measurement · doi:10.1016/j.measurement.2019.02.040 · Cited by 94
Steenkiste, G. V., van Loon, G., & Crevecoeur, G. (2020) · Scientific Reports · doi:10.1038/s41598-019-57025-2 · Cited by 64
Metadata
- Authors
- Lanata, A., Guidi, A., Baragli, P., Valenza, G., & Scilingo, E. P.
- Affiliations
- University of Pisa (IT)
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-10-20
- Volume
- 10
- Issue
- 10
- Pages
- e0140783
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC4618928
- OpenAlex
- W2100756879
- Cited by
- 42
- References
- 72
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 1 · 2023: 5 · 2022: 4 · 2021: 2 · 2020: 4 · 2019: 6 · 2018: 4 · 2017: 6 · 2016: 4
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Florence Research (University of Florence) (submittedVersion, other-oa)
- RePEc: Research Papers in Economics (submittedVersion)
- CINECA IRIS Institutial research information system (University of Pisa) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- ECG denoising, horses, wearable ECG monitoring, stationary wavelet transform, adaptive filtering, triaxial accelerometer, textile electrodes, equine electrocardiography
- MeSH terms
- Algorithms, Animals, Electrocardiography, Horses, Movement, Signal Processing, Computer-Assisted, Artifacts, Wavelet Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Novel Algorithm for Movement Artifact Removal in ECG Signals Acquired from Wearable Systems Applied to Horses. https://app.cochat.ai/papers/10.1371/journal.pone.0140783
- The paper
- Lanata, A., Guidi, A., Baragli, P., Valenza, G., & Scilingo, E. P. (2015). A Novel Algorithm for Movement Artifact Removal in ECG Signals Acquired from Wearable Systems Applied to Horses. PLOS ONE. https://doi.org/10.1371/journal.pone.0140783
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.