Musculoskeletal Geometry, Muscle Architecture and Functional Specialisations of the Mouse Hindlimb
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Mice are one of the most commonly used laboratory animals, with an extensive array of disease models in existence, including for many neuromuscular diseases. The hindlimb is of particular interest due to several close muscle analogues/homologues to humans and other species. A detailed anatomical study describing the adult morphology is lacking, however. This study describes in detail the musculoskeletal geometry and skeletal muscle architecture of the mouse hindlimb and pelvis, determining the extent to which the muscles are adapted for their function, as inferred from their architecture. Using I2KI enhanced microCT scanning and digital segmentation, it was possible to identify 39 distinct muscles of the hindlimb and pelvis belonging to nine functional groups. The architecture of each of these muscles was determined through microdissections, revealing strong architectural specialisations between the functional groups. The hip extensors and hip adductors showed significantly stronger adaptations towards high contraction velocities and joint control relative to the distal functional groups, which exhibited larger physiological cross sectional areas and longer tendons, adaptations for high force output and elastic energy savings. These results suggest that a proximo-distal gradient in muscle architecture exists in the mouse hindlimb. Such a gradient has been purported to function in aiding locomotor stability and efficiency. The data presented here will be especially valuable to any research with a focus on the architecture or gross anatomy of the mouse hindlimb and pelvis musculature, but also of use to anyone interested in the functional significance of muscle design in relation to quadrupedal locomotion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metscher, B. D. (2009) · BMC Physiology · doi:10.1186/1472-6793-9-11 · Cited by 1,086
Cited by
Kenjo, E., Hozumi, H., Makita, Y., Iwabuchi, K. A., Fujimoto, N., Matsumoto, S., Kimura, M., Amano, Y., Ifuku, M., Naoe, Y., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-26714-w · Cited by 300
Skeletal muscle and fiber type-specific intramyocellular lipid accumulation in obese mice
Umek, N., Horvat, S., & Cvetko, E. (2021) · Biomolecules and Biomedicine · doi:10.17305/bjbms.2021.5876 · Cited by 41
“However, in these investigations, antagonistic muscles were compared, which may influence the IMCL content due to the potential differential effect of increased body weight on skeletal muscle load during long-term high-fat diet treatment protocols [31].”
BackgroundA Whole-Body Musculoskeletal Model of the Mouse
Tata Ramalingasetty, S., Danner, S. M., Arreguit, J., Markin, S. N., Rodarie, D., Kathe, C., Courtine, G., Rybak, I. A., & Ijspeert, A. J. (2021) · IEEE Access · doi:10.1109/access.2021.3133078 · Cited by 35
“These steps were traditionally performed directly on cadavers [35]; later studies, used microCT scans along with digital segmentation, which lead to more detailed identification about muscle geometry and attachments, especially for deep muscles [49].”
BackgroundWang, X., Wei, Z., Gu, M., Zhu, L., Hai, C., Di, A., Wu, D., Bai, C., Su, G., Liu, X., et al. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms232415707 · Cited by 29
FARMS: Framework for Animal and Robot Modeling and Simulation
Arreguit, J., Tata Ramalingasetty, S., Danner, S. M., & Ijspeert, A. (2023) · doi:10.1101/2023.09.25.559130 · Cited by 12
Metadata
- Authors
- Charles, J. P., Cappellari, O., Spence, A. J., Hutchinson, J. R., & Wells, D. J.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2016-04-26
- Volume
- 11
- Issue
- 4
- Pages
- e0147669
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2343378530
- Cited by
- 164
- References
- 1
- FWCI
- 16.24
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.