Quantification of Influenza Virus RNA in Aerosols in Patient Rooms
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The potential for human influenza viruses to spread through fine particle aerosols remains controversial. The objective of our study was to determine whether influenza viruses could be detected in fine particles in hospital rooms. METHODS AND FINDINGS: We sampled the air in 2-bed patient isolation rooms for four hours, placing cyclone samplers at heights of 1.5m and 1.0m. We collected ten air samples each in the presence of at least one patient with confirmed influenza A virus infection, and tested the samples by reverse transcription polymerase chain reaction. We recovered influenza A virus RNA from 5/10 collections (50%); 4/5 were from particles>4 μm, 1/5 from 1-4 μm, and none in particles<1 μm. CONCLUSIONS: Detection of influenza virus RNA in aerosols at low concentrations in patient rooms suggests that healthcare workers and visitors might have frequent exposure to airborne influenza virus in proximity to infected patients. A limitation of our study was the small sample size. Further studies should be done to quantify the concentration of viable influenza virus in healthcare settings, and factors affecting the detection of influenza viruses in fine particles in the air.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Milton, D. K., Fabian, M. P., Cowling, B. J., Grantham, M. L., & McDevitt, J. J. (2013) · PLoS Pathogens · doi:10.1371/journal.ppat.1003205 · Cited by 669
Self-citationThe role of particle size in aerosolised pathogen transmission: a review
Gralton, J., Tovey, E., McLaws, M.-L., & Rawlinson, W. D. (2011) · Journal of Infection · doi:10.1016/j.jinf.2010.11.010 · Cited by 665
Exposure to Influenza Virus Aerosols During Routine Patient Care
Bischoff, W. E., Swett, K., Leng, I., & Peters, T. R. (2013) · The Journal of Infectious Diseases · doi:10.1093/infdis/jis773 · Cited by 226
A two-stage cyclone using microcentrifuge tubes for personal bioaerosol sampling.
Lindsley, W. G., Schmechel, D., & Chen, B. T. (2006) · Journal of Environmental Monitoring · doi:10.1039/b609083d · Cited by 117 · cited 5×
“The tripod, air tubing, sound-proof box and the meter were disinfected with Med-Clean (M&W International Ltd., Hong Kong), the NIOSH air samplers with 2% Citranox (Alconox Inc, NY, USA), and the filter cassettes were autoclaved.”
MethodInfluentialSelf-citation
Cited by
Transmissibility and transmission of respiratory viruses
Leung, N. H. L. (2021) · Nature Reviews Microbiology · doi:10.1038/s41579-021-00535-6 · Cited by 890
Self-citationRecognition of aerosol transmission of infectious agents: a commentary
Tellier, R., Li, Y., Cowling, B. J., & Tang, J. W. (2019) · BMC Infectious Diseases · doi:10.1186/s12879-019-3707-y · Cited by 746
Self-citationPaules, C., & Subbarao, K. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30129-0 · Cited by 740
Particle Sizes of Infectious Aerosols: Implications for Infection Control
Fennelly, K. P. (2020) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(20)30323-4 · Cited by 621
Shiu, E. Y. C., Leung, N. H. L., & Cowling, B. J. (2019) · Current Opinion in Infectious Diseases · doi:10.1097/qco.0000000000000563 · Cited by 235
Self-citation
Metadata
- Authors
- Leung, N. H. L., Zhou, J., Chu, D. K. W., Yu, H., Lindsley, W. G., Beezhold, D. H., Yen, H.-L., Li, Y., Seto, W.-H., Peiris, J. S. M., & Cowling, B. J.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2016-02-05
- Volume
- 11
- Issue
- 2
- Pages
- e0148669
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2255559468
- Cited by
- 63
- References
- 4
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantification of Influenza Virus RNA in Aerosols in Patient Rooms. https://app.cochat.ai/papers/10.1371/journal.pone.0148669
- The paper
- Leung, N. H. L., Zhou, J., Chu, D. K. W., Yu, H., Lindsley, W. G., Beezhold, D. H., Yen, H.-L., Li, Y., Seto, W.-H., Peiris, J. S. M., & Cowling, B. J. (2016). Quantification of Influenza Virus RNA in Aerosols in Patient Rooms. PLOS ONE. https://doi.org/10.1371/journal.pone.0148669
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.