Insulin Pump Therapy Is Associated with Lower Rates of Retinopathy and Peripheral Nerve Abnormality
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To compare rates of microvascular complications in adolescents with type 1 diabetes treated with continuous subcutaneous insulin infusion (CSII) versus multiple daily injections (MDI). RESEARCH DESIGN AND METHODS: Prospective cohort of 989 patients (aged 12-20 years; diabetes duration >5 years) treated with CSII or MDI for >12 months. Microvascular complications were assessed from 2000-14: early retinopathy (seven-field fundal photography), peripheral nerve function (thermal and vibration threshold testing), autonomic nerve abnormality (heart rate variability analysis of electrocardiogram recordings) and albuminuria (albumin creatinine ratio/timed overnight albumin excretion). Generalized estimating equations (GEE) were used to examine the relationship between treatment and complications rates, adjusting for socio-economic status (SES) and known risk factors including HbA1c and diabetes duration. RESULTS: Comparing CSII with MDI: HbA1C was 8.6% [70mmol/mol] vs. 8.7% [72 mmol/mol]) (p = 0.7), retinopathy 17% vs. 22% (p = 0.06); microalbuminuria 1% vs. 4% (p = 0.07), peripheral nerve abnormality 27% vs. 33% (p = 0.108) and autonomic nerve abnormality 24% vs. 28% (p = 0.401). In multivariable GEE, CSII use was associated with lower rates of retinopathy (OR 0.66, 95% CI 0.45-0.95, p = 0.029) and peripheral nerve abnormality (OR 0.63, 95% CI 0.42-0.95, p = 0.026), but not albuminuria (OR 0.46, 95% CI 0.10-2.17, p = 0.33). SES was not associated with any of the complication outcomes. CONCLUSIONS: In adolescents, CSII use is associated with lower rates of retinopathy and peripheral nerve abnormality, suggesting an apparent benefit of CSII over MDI independent of glycemic control or SES.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Diabetes Control and Complications Trial Research Group (1995) · Diabetes · doi:10.2337/diab.44.8.968 · Cited by 1,301
Yeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-5-201209040-00508 · Cited by 493
Jeitler, K., Horvath, K., Berghold, A., Gratzer, T. W., Neeser, K., Pieber, T. R., & Siebenhofer, A. (2008) · Diabetologia · doi:10.1007/s00125-008-0974-3 · Cited by 375
(2015) · doi:10.1136/bmj.h3234 · Cited by 258
Safety and effectiveness of insulin pump therapy in children and adolescents with type 1 diabetes
Plotnick, L. P., Clark, L. M., Brancati, F. L., & Erlinger, T. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1142 · Cited by 216 · cited 2×
“The advantage of CSII is its ability to better mimic physiological insulin release, which may provide a more efficient supply of insulin to the tissues and minimize the risk of hypoglycemic events [4, 10].”
BackgroundThe possible role of postprandial hyperglycaemia in the pathogenesis of diabetic complications
Ceriello, A. (2003) · Diabetologia · doi:10.1007/s00125-002-0931-5 · Cited by 181 · cited 2×
“We speculate that CSII is likely to confer a more stable glycaemic profile independent of glycated haemoglobin [23, 24].”
BackgroundInsulin pump-associated adverse events in children and adolescents–a prospective study
Wheeler, B. J., Heels, K., Donaghue, K. C., Reith, D. M., & Ambler, G. R. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0388 · Cited by 64 · cited 1×
“In contrast to these advantages, adverse events have also been reported with insulin pump therapy including pump malfunction, infusion set/site failure and catheter infection [12, 13].”
BackgroundSelf-citationFamily Perceptions of Insulin Pump Adverse Events in Children and Adolescents
Wheeler, B. J., Donaghue, K. C., Heels, K., & Ambler, G. R. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0315 · Cited by 31 · cited 1×
“In contrast to these advantages, adverse events have also been reported with insulin pump therapy including pump malfunction, infusion set/site failure and catheter infection [12, 13].”
Self-citation
Cited by
Karges, B., Schwandt, A., Heidtmann, B., Kordonouri, O., Binder, E., Schierloh, U., Boettcher, C., Kapellen, T., Rosenbauer, J., & Holl, R. W. (2017) · JAMA · doi:10.1001/jama.2017.13994 · Cited by 452
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
7. Diabetes Technology: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s007 · Cited by 202
“There is also evidence that CSII may reduce DKA risk (143,148) and diabetes complications, in particular, retinopathy and peripheral neuropathy in youth, compared with MDI (65).”
BackgroundISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
van den Boom, L., Karges, B., Auzanneau, M., Rami-Merhar, B., Lilienthal, E., von Sengbusch, S., Datz, N., Schröder, C., Kapellen, T., Laimer, M., et al. (2019) · Diabetes Care · doi:10.2337/dc19-0345 · Cited by 191
“complications (3,4) as well as the risk of acute complications, such as severe hypoglycemia and diabetic ketoacidosis (2) in patients with type 1 diabetes.”
Background7. Diabetes Technology: Standards of Medical Care in Diabetes—2019
American Diabetes Association (2019) · Diabetes Care · doi:10.2337/dc19-s007 · Cited by 179
ISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Insulin delivery
Sherr, J. L., Schoelwer, M., Dos Santos, T. J., Reddy, L., Biester, T., Galderisi, A., van Dyk, J. C., Hilliard, M. E., Berget, C., & DiMeglio, L. A. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13421 · Cited by 152
Virk, S. A., Donaghue, K. C., Cho, Y. H., Benitez-Aguirre, P., Hing, S., Pryke, A., Chan, A., & Craig, M. E. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2015-3604 · Cited by 109
Self-citationCurrent trends of digital solutions for diabetes management
Neborachko, M., Pkhakadze, A., & Vlasenko, I. (2019) · Diabetes & Metabolic Syndrome: Clinical Research & Reviews · doi:10.1016/j.dsx.2018.07.014 · Cited by 36
Metadata
- Authors
- Zabeen, B., Craig, M. E., Virk, S. A., Pryke, A., Chan, A. K. F., Cho, Y. H., Benitez-Aguirre, P. Z., Hing, S., & Donaghue, K. C.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2016-04-06
- Volume
- 11
- Issue
- 4
- Pages
- e0153033
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2323362493
- Cited by
- 106
- References
- 8
- FWCI
- 10.97
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.