The Lancet Weight Determines Wheal Diameter in Response to Skin Prick Testing with Histamine
Open accessThe DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Skin prick test (SPT) is a common test for diagnosing immunoglobulin E-mediated allergies. In clinical routine, technicalities, human errors or patient-related biases, occasionally results in suboptimal diagnosis of sensitization. OBJECTIVE: Although not previously assessed qualitatively, lancet weight is hypothesized to be important when performing SPT to minimize the frequency of false positives, false negatives, and unwanted discomfort. METHODS: Accurate weight-controlled SPT was performed on the volar forearms and backs of 20 healthy subjects. Four predetermined lancet weights were applied (25 g, 85 g, 135 g and 265 g) using two positive control histamine solutions (1 mg/mL and 10 mg/mL) and one negative control (saline). A total of 400 SPTs were conducted. The outcome parameters were: wheal size, neurogenic inflammation (measured by superficial blood perfusion), frequency of bleeding, and the lancet provoked pain response. RESULTS: The mean wheal diameter increased significantly as higher weights were applied to the SPT lancet, e.g. from 3.2 ± 0.28 mm at 25 g to 5.4 ± 1.7 mm at 265 g (p<0.01). Similarly, the frequency of bleeding, the provoked pain, and the neurogenic inflammatory response increased significantly. At 265 g saline evoked two wheal responses (/160 pricks) below 3 mm. CONCLUSION AND CLINICAL RELEVANCE: The applied weight of the lancet during the SPT-procedure is an important factor. Higher lancet weights precipitate significantly larger wheal reactions with potential diagnostic implications. This warrants additional research of the optimal lancet weight in relation to SPT-guidelines to improve the specificity and sensitivity of the procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The sensitivity and specificity of SPT depends on the allergen tested, quality of reagents, the specific methodologies employed, technician expertise, and patient demographics.928,937-942”
From International Consensus Statement on Allergy and Rhinology: Allergic Rhinitis (2018) · cites this paper as [938]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“For example, SPT wheal size and sensitivity depend on the specific device selection and the choice of control reagents used for testing.928,938”
From International Consensus Statement on Allergy and Rhinology: Allergic Rhinitis (2018) · cites this paper as [938]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rolke, R., Baron, R., Maier, C., Tölle, T. R., Treede, D. R., Beyer, A., Binder, A., Birbaumer, N., Birklein, F., Bötefür, I. C., et al. (2006) · Pain · doi:10.1016/j.pain.2006.01.041 · Cited by 2,609
Maier, C., Baron, R., Tölle, T. R., Binder, A., Birbaumer, N., Birklein, F., Gierthmühlen, J., Flor, H., Geber, C., Huge, V., et al. (2010) · Pain · doi:10.1016/j.pain.2010.05.002 · Cited by 1,021
Allergic rhinitis: Definition, epidemiology, pathophysiology, detection, and diagnosis
Skoner, D. P. (2001) · Journal of Allergy and Clinical Immunology · doi:10.1067/mai.2001.115569 · Cited by 914
Position Paper: Allergen standardization and skin tests
Dreborg, S., & Frew, A. (1993) · Allergy · doi:10.1111/j.1398-9995.1993.tb04756.x · Cited by 753
Allergy Diagnostic Testing: An Updated Practice Parameter
Bernstein, I. L., Li, J. T., Bernstein, D. I., Hamilton, R., Spector, S. L., Tan, R., Sicherer, S., Golden, D. B. K., Khan, D. A., Nicklas, R. A., et al. (2008) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)60305-5 · Cited by 723 · cited 2×
“patients suffering from dermatographic urticaria from being falsely diagnosed with an allergy [15,16,21].”
BackgroundMethodThe Skin Prick Test—European Standards
Heinzerling, L., Mari, A., Bergmann, K., Bresciani, M., Burbach, G., Darsow, U., Durham, S., Fokkens, W., Gjomarkaj, M., Haahtela, T., et al. (2013) · Clinical and Translational Allergy · doi:10.1186/2045-7022-3-3 · Cited by 681 · cited 11×
“This setup is in line with the European recommendations of SPT standardization [13].”
BackgroundMethodResultInfluentialFatalities from immunotherapy (IT) and skin testing (ST)
Lockey, R. F., Benedict, L. M., Turkeltaub, P. C., & Bukantz, S. C. (1987) · Journal of Allergy and Clinical Immunology · doi:10.1016/s0091-6749(87)80164-1 · Cited by 570 · cited 1×
“Higher lancet weights are positively associated with several unwanted aspects of SPT such as patient discomfort, risk of adverse events (although rare in response to SPT they do occur [51,52]), blood drawing and likely the incidence of false positives.”
BackgroundEpidemiology of hypersensitivity drug reactions
Gomes, E. R., & Demoly, P. (2005) · Current Opinion in Allergy & Clinical Immunology · doi:10.1097/01.all.0000173785.81024.33 · Cited by 410
Gergen, P. J., Turkeltaub, P. C., & Kovar, M. G. (1987) · Journal of Allergy and Clinical Immunology · doi:10.1016/0091-6749(87)90286-7 · Cited by 281
The Cutaneous Microcirculation: Ultrastructure and Microanatomical Organization
Braverman, I. M. (1997) · Microcirculation · doi:10.3109/10739689709146797 · Cited by 239 · cited 1×
“5 mm below the upper layer of epidermis [47,48].”
Background
Cited by
International Consensus Statement on Allergy and Rhinology: Allergic Rhinitis
Wise, S. K., Lin, S. Y., Toskala, E., Orlandi, R. R., Akdis, C. A., Alt, J. A., Azar, A., Baroody, F. M., Bachert, C., Canonica, G. W., et al. (2018) · International Forum of Allergy & Rhinology · doi:10.1002/alr.22073 · Cited by 557
International consensus statement on allergy and rhinology: Allergic rhinitis – 2023
Wise, S. K., Damask, C., Roland, L. T., Ebert, C., Levy, J. M., Lin, S., Luong, A., Rodriguez, K., Sedaghat, A. R., Toskala, E., et al. (2023) · International Forum of Allergy & Rhinology · doi:10.1002/alr.23090 · Cited by 507
Nonhistaminergic and mechanical itch sensitization in atopic dermatitis
Andersen, H. H., Elberling, J., Sølvsten, H., Yosipovitch, G., & Arendt‐Nielsen, L. (2017) · Pain · doi:10.1097/j.pain.0000000000000980 · Cited by 96
Self-citationJensen-Jarolim, E., Jensen, A. N., & Canonica, G. W. (2017) · World Allergy Organization Journal · doi:10.1186/s40413-017-0162-3 · Cited by 49
“Importantly, the mean wheal diameter resulting from the prick has been shown to be affected by the personnel testing and by the lancet weight [21], and is differing between test centers, naturally depending on the concentration of the histamine solution used: a 1 mg/ml solution with wheals between 3 and 6.”
MethodModulation of Itch by Conditioning Itch and Pain Stimulation in Healthy Humans
Andersen, H. H., van Laarhoven, A. I. M., Elberling, J., & Arendt‐Nielsen, L. (2017) · Journal of Pain · doi:10.1016/j.jpain.2017.07.002 · Cited by 35
Self-citationAndersen, H. H., Sřrensen, A., Nielsen, G., Mřlgaard, M., Stilling, P., Boudreau, S. A., Elberling, J., & Arendt‐Nielsen, L. (2016) · Acta Dermato Venereologica · doi:10.2340/00015555-2502 · Cited by 29
“The controlled pressure applied was aimed at increasing reliability and based on an initial pilot study showing that 120 g was sufficient to establish a wheal > 3 mm in diameter in all participants, while minimizing the occurrence of bleeding (34, 35).”
MethodSelf-citationEpinephrine auto-injector needle lengths
Dreborg, S. K. G., Kim, L., Tsai, G., & Kim, H. L. (2018) · Annals of Allergy Asthma & Immunology · doi:10.1016/j.anai.2018.02.028 · Cited by 25
Robust automated reading of the skin prick test via 3D imaging and parametric surface fitting
Pineda, J. D., Vargas, R., Romero, L. A., Marrugo, J., Meneses, J. E., & Marrugo, A. G. (2019) · PLoS ONE · doi:10.1371/journal.pone.0223623 · Cited by 19
“Hence, the need for continuous optimization of related diagnostic tools and therapies [5].”
BackgroundMedical devices in allergy practice
Popov, T. A., Passalacqua, G., Díaz, S. N. G., Plavec, D., Braido, F., Garcia‐Abujeta, J. L., DuBuske, L. M., Rouadi, P. W., Morais‐Almeida, M., Bonini, S., et al. (2020) · World Allergy Organization Journal · doi:10.1016/j.waojou.2020.100466 · Cited by 23
“Again, another study evaluated the influence of the weight of the devices used (lancets and needles) and concluded that lighter devices could provide more reproducible results.(12) A meta-analysis focusing the diagnostic accuracy of SPT included 7 studies.”
BackgroundRøikjer, J., Croosu, S. S., Hansen, T. M., Frøkjær, J. B., Andersen, H. H., Arendt‐Nielsen, L., Mørch, C. D., & Ejskjær, N. (2022) · Journal of Pain · doi:10.1016/j.jpain.2022.01.002 · Cited by 17
Self-citationImplications of variation of epinephrine auto-injector needle length
Dreborg, S. K. G., Tsai, G., & Kim, H. L. (2019) · Annals of Allergy Asthma & Immunology · doi:10.1016/j.anai.2019.04.027 · Cited by 14
Andersen, H. H., Elberling, J., Sharma, N., Hauberg, L. E., Gazerani, P., & Arendt‐Nielsen, L. (2017) · European Journal of Pain · doi:10.1002/ejp.1013 · Cited by 14
“A droplet of histamine solution was placed on the skin and the SPT lancet was pierced through the histamine with 120 g of pressure as previously described (Andersen et al., 2016).”
MethodSelf-citationIgE-Mediated food allergy: Current diagnostic modalities and novel biomarkers with robust potential
Xie, Q., & Xue, W. (2022) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2022.2075312 · Cited by 14
“%) and positive (histamine, 10 mg/mL) controls are required (Andersen et al. 2016).”
BackgroundAllergic and Non-allergic Rhinitis
Al-Ahmad, M. S., Hassab, M., & Ansari, A. A. (2020) · Springer eBooks · doi:10.1007/978-3-030-54088-3_22 · Cited by 11
Ndlovu, V., Chimbari, M. J., Sibanda, E., & Ndarukwa, P. (2021) · Pilot and Feasibility Studies · doi:10.1186/s40814-021-00780-9 · Cited by 10
Almeida, A. L. M., Perger, E. L. P., Gomes, R. H. M., Sousa, G. D. S., Vasques, L. H., Rodokas, J. E. P., Neto, J. O., & Simões, R. P. (2020) · Journal of Immunological Methods · doi:10.1016/j.jim.2020.112870 · Cited by 7
Røikjer, J., Croosu, S. S., Borbjerg, M. K., Hansen, T. M., Frøkjær, J. B., Arendt‐Nielsen, L., Ejskjær, N., & Mørch, C. D. (2023) · Muscle & Nerve · doi:10.1002/mus.27925 · Cited by 7
“The application was followed by the application of a simple, handheld, skin-prick lancet (Aalborg University, Aalborg, Denmark) with a standardized 85 g pressure to allow the histamine to penetrate the skin.(25) Images of the dermal blood flow were captured using an FLPI-device (Moor Instruments, Axminster, UK) and an…”
MethodSelf-citationEpinephrine auto-injector needle length
Dreborg, S. K. G., Tsai, G., & Kim, H. L. (2020) · Allergy Asthma and Clinical Immunology · doi:10.1186/s13223-020-00422-4 · Cited by 7
Dreborg, S. K. G., & Kim, H. L. (2018) · Annals of Allergy Asthma & Immunology · doi:10.1016/j.anai.2018.09.456 · Cited by 7
Shoormasti, R. S., Mahloujirad, M., Sabetkish, N., Kazemnejad, A., Dana, V. G., Tayebi, B., Abbasi, J. M., Sadri, H., Fazlollahi, M. R., Pourpak, Z., et al. (2020) · Dermatologic Therapy · doi:10.1111/dth.14636 · Cited by 5
“Epidermal deposition of allergens will result in local reactions including wheal and flare.(7) Wheal is developed as a result of the linkage of histamine and their receptors and accordingly plasma extravasation around extract exposure.”
BackgroundHistamine Skin Prick Tests: From Established Diagnostic Technique to Advanced Experimental Biomarker
Bamps, D., Berdon, K., Hernandez, H., Schrijvers, R., & Hoon, J. N. J. M. D. (2023) · Skin Pharmacology and Physiology · doi:10.1159/000528772 · Cited by 5
The effect of applied force and device design on skin prick test performance
Chiaranairungroj, M., Chatchatee, P., & Srituravanich, W. (2022) · Annals of Allergy Asthma & Immunology · doi:10.1016/j.anai.2022.11.014 · Cited by 7
Dreborg, S. K. G. (2017) · Journal of Medical Diagnostic Methods · doi:10.4172/2168-9784.1000242 · Cited by 3
Deep Learning Method Applied to Autonomous Image Diagnosis for Prick Test
Gomes, R. H. M., Perger, E. L. P., Vasques, L. H., Gagete, E., & Simões, R. P. (2024) · Life · doi:10.3390/life14101256 · Cited by 4
“Skin pigmentation presents another complication, making it difficult to identify the reaction outline Additionally, wheal location (e.g., volar vs. infrascapular region) can influence the result [9].”
BackgroundSuh, M. J., Park, J. A., Ko, H., Kang, M., Kim, J., Lee, J.-I., Kim, J., Baek, S., Lee, K.-H., Hong, S.-C., et al. (2021) · American Journal of Rhinology and Allergy · doi:10.1177/19458924211032469 · Cited by 3
“10–14 Furthermore, allergen-induced skin prick reactions are well known for their variability due to factors such as age, gender, concomitant medications, and seasonal variations.(15) Based on the above, we have previously examined the effect of BMI on histamine skin reaction (HSR), which is used as a positive control.”
BackgroundToward an automatic 3D measurement of skin wheals from skin prick tests
Marrugo, A. G., Romero, L. A., Pineda, J. D., Vargas, R., Altamar-Mercado, H., Marrugo, J., & Meneses, J. E. (2019) · Dimensional Optical Metrology and Inspection for Practical Applications · doi:10.1117/12.2519034 · Cited by 2
“(5) can model a wide range of wheal shapes and sizes, thus it is suitable for robust diameter measurement.”
BackgroundDiagnostic accuracy and safety of Dermatophagoides pteronyssinus extracts used for skin prick test
Tang, R., Lyu, X., Liu, Y., Wang, R., Wang, L., Li, H., Sun, J., Zhi, Y., Gu, J., Guan, K., et al. (2022) · Chinese Medical Journal · doi:10.1097/cm9.0000000000002262 · Cited by 6
“In addition to the allergen allergy itself, the accuracy of the SPT results is affected by many factors, including skin reactivity, age,([23]) medication,([24]) needle material,([25]) and manipulation.”
BackgroundTind, P., Larsen, A., Borbjerg, M. K., Vecchio, S. L., Frahm, K. S., Ejskjær, N., Mørch, C. D., & Røikjer, J. (2024) · Muscle & Nerve · doi:10.1002/mus.28325 · Cited by 1
“…histamine-induced ARF response, one drop of histamine 10 mg/mL (ALK Soluprick, Denmark) was placed in the predefined area and applied in-traepidermally using a skin-prick lancet (Aalborg University, Aalborg, Denmark) with a fixed 80–85 g pressure to allow the histamine to penetrate the skin [19].”
Bartko, E. A., Elberling, J., & Mosbech, H. (2024) · World Allergy Organization Journal · doi:10.1016/j.waojou.2024.100915 · Cited by 2
Self-citationWhite, K. (2023) · Annals of Allergy Asthma & Immunology · doi:10.1016/j.anai.2022.12.029
Røikjer, J. (2022) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau528830728
การพัฒนาเพื่อเพิ่มสมรรถนะของอุปกรณ์ทดสอบภูมิแพ้ทางผิวหนังประเภทพลาสติก
เจียระไนรุ่งโรจน์, ม. (2021) · Chula Digiverse · doi:10.58837/chula.the.2021.959
Vecchio, S. L., Aliotta, G. E., Okutani, H., Ammitzbøll, N., Wegeberg, A., Drewes, A. M., & Arendt‐Nielsen, L. (2025) · Experimental Dermatology · doi:10.1111/exd.70149
Self-citationNdlovu, V., Chimbari, M., Sibanda, E., & Ndarukwa, P. (2021) · Figshare · doi:10.6084/m9.figshare.14091547
Automated Image-Based Detection and Measurement of Wheal Responses in Skin Prick Test Images
Punamiya, Z., & DESAI, S. D. (2026) · Impact in Computics · doi:10.65500/computics-2026-006
Metadata
- Authors
- Andersen, H. H., Lundgaard, A. C., Petersen, A. S., Hauberg, L. E., Sharma, N., Hansen, S. D., Elberling, J., & Arendt-Nielsen, L.
- Affiliations
- Aalborg University (DK)
- Gentofte Hospital (DK)
- Corresponding author
- Andersen, Hjalte H.
- Lundgaard, Anna Charlotte
- Petersen, Anne S.
- Hauberg, Lise E.
- Sharma, Neha
- Hansen, Sofie D.
- Elberling, Jesper
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2016-05-23
- Volume
- 11
- Issue
- 5
- Pages
- e0156211
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC4877047
- OpenAlex
- W2404945632
- Cited by
- 35
- References
- 55
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 3 · 2023: 4 · 2022: 5 · 2021: 4 · 2020: 5 · 2019: 3 · 2018: 3 · 2017: 5 · 2016: 1
- FWCI
- 3.78
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- VBN Forskningsportal (Aalborg Universitet) (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Figshare (submittedVersion, cc-by)
- Funders
- Aalborg Universitet
- Gentofte Hospital
- Topics
- Health Sciences › Medicine › Immunology and Allergy › Allergic Rhinitis and Sensitization
- Health Sciences › Medicine › Immunology and Allergy › Food Allergy and Anaphylaxis Research
- Life Sciences › Immunology and Microbiology › Immunology › Mast cells and histamine
- Keywords
- skin prick test, wheal diameter, histamine, neurogenic inflammation, skin bleeding, allergy diagnosis, immunoglobulin E-mediated allergy, test reproducibility
- MeSH terms
- Adolescent, Adult, Female, Forearm, Histamine, Humans, Hypersensitivity, Immediate, Immunoglobulin E, Male, Middle Aged, Predictive Value of Tests, Sensitivity and Specificity, Skin Tests, Urticaria, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.