Estimation of Physical Activity Energy Expenditure during Free-Living from Wrist Accelerometry in UK Adults
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Wrist-worn accelerometers are emerging as the most common instrument for measuring physical activity in large-scale epidemiological studies, though little is known about the relationship between wrist acceleration and physical activity energy expenditure (PAEE). METHODS: 1695 UK adults wore two devices simultaneously for six days; a combined sensor and a wrist accelerometer. The combined sensor measured heart rate and trunk acceleration, which was combined with a treadmill test to yield a signal of individually-calibrated PAEE. Multi-level regression models were used to characterise the relationship between the two time-series, and their estimations were evaluated in an independent holdout sample. Finally, the relationship between PAEE and BMI was described separately for each source of PAEE estimate (wrist acceleration models and combined-sensing). RESULTS: Wrist acceleration explained 44-47% between-individual variance in PAEE, with RMSE between 34-39 J•min-1•kg-1. Estimations agreed well with PAEE in cross-validation (mean bias [95% limits of agreement]: 0.07 [-70.6:70.7]) but overestimated in women by 3% and underestimated in men by 4%. Estimation error was inversely related to age (-2.3 J•min-1•kg-1 per 10y) and BMI (-0.3 J•min-1•kg-1 per kg/m2). Associations with BMI were similar for all PAEE estimates (approximately -0.08 kg/m2 per J•min-1•kg-1). CONCLUSIONS: A strong relationship exists between wrist acceleration and PAEE in free-living adults, such that irrespective of the objective method of PAEE assessment, a strong inverse association between PAEE and BMI was observed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This device has demonstrated equivalent output49 to the GENEActiv accelerometer, which has been validated using both standard laboratory and free-living energy expenditure assessment methods50,51.”
From GWAS identifies 14 loci for device-measured physical activity and sleep duration (2018) · cites this paper as [51]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The total volume of PA was measured as the weekly average vector magnitude in milligravity (mg) units (field ID 90012), which is a wellvalidated surrogate for global PA.17,18”
From Joint association of physical activity and sleep duration with risk of all-cause and cause-specific mortality: A population-based cohort study using accelerometry (2023) · cites this paper as [17]
Experimental — accuracy not yet measuredIn the citing paper
“This variable has been shown to account for 44–47% explained variance vs. combined sensing heart-rate + trunk-acceleration (a proxy for free-living physical activity energy expenditure) in 1695 UK adults51.”
From GWAS identifies 14 loci for device-measured physical activity and sleep duration (2018) · cites this paper as [51]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lee, I.-M., Shiroma, E. J., Lobelo, F., Puska, P., Blair, S. N., & Katzmarzyk, P. T. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61031-9 · Cited by 8,215
Fit Yourself and Take Your Lungs to Heart
Palange, P., & Bonini, M. (2013) · Respiration · doi:10.1159/000350831 · Cited by 2,779
van Hees, V. T., Gorzelniak, L., Dean León, E. C., Eder, M., Pias, M., Taherian, S., Ekelund, U., Renström, F., Franks, P. W., Horsch, A., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0061691 · Cited by 926
Self-citationvan Hees, V. T., Fang, Z., Langford, J., Assah, F., Mohammad, A., da Silva, I. C. M., Trenell, M. I., White, T., Wareham, N. J., & Brage, S. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00421.2014 · Cited by 676
Self-citationReliability and validity of the combined heart rate and movement sensor Actiheart
Brage, S., Brage, N., Franks, P. W., Ekelund, U., & Wareham, N. J. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602118 · Cited by 667
Self-citationValidation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625
Kilpeläinen, T. O., Qi, L., Brage, S., Sharp, S. J., Sonestedt, E., Demerath, E., Ahmad, T., Mora, S., Kaakinen, M., Sandholt, C. H., et al. (2011) · PLoS Medicine · doi:10.1371/journal.pmed.1001116 · Cited by 559
Self-citationBrage, S., Brage, N., Franks, P. W., Ekelund, U., Wong, M.-Y., Andersen, L. B., Froberg, K., & Wareham, N. J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00703.2003 · Cited by 473
Self-citationValidity and repeatability of the EPIC-Norfolk Physical Activity Questionnaire
Wareham, N. J., Jakes, R. W., Rennie, K. L., Mitchell, J., Hennings, S., & Day, N. E. (2002) · International Journal of Epidemiology · doi:10.1093/ije/31.1.168 · Cited by 435
Self-citationBrage, S., Ekelund, U., Brage, N., Hennings, M. A., Froberg, K., Franks, P. W., & Wareham, N. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00092.2006 · Cited by 303
Self-citation
Research works printed but not linked: 1
- Troiano R, McClain J. Objective measures of physical activity, sleep, and strength in US National Health and Nutrition Examination Survey (NHANES) 2011–2014. Proceedings of the 8th International Conference on Diet and Activity Methods. Rome, Italy; 2012. Available: http://www.fao.org/fileadmin/templates/food_composition/documents/ABSTRACT_BOOK.pdf
Cited by
Items 101–169 of 169
Perez-Pozuelo, I., White, T., Westgate, K. L., Wijndaele, K., Wareham, N. J., & Brage, S. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2019-0024 · Cited by 8
Self-citationA software system for the assessment of the sleep-wake rhythm using Axivity AX3
Scalera, M., Latrofa, S., Lomonte, N., Tauro, G., & Gentile, E. (2022) · International Conference on Smart and Sustainable Technologies (SpliTech) · doi:10.23919/splitech55088.2022.9854306 · Cited by 4
“Studies have been carried out on the efficiency of actigraphs with good results [23] [24] [25] [26] [27] [28] [29].”
BackgroundEstimation of the metabolic rate in the occupational field: a regression model using accelerometers
Falcone, T., Ferraro, S. D., Molinaro, V., Zollo, L., & Lenzuni, P. (2023) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2023.103454 · Cited by 5
Bayesian hierarchical modeling and analysis for actigraph data from wearable devices
Loro, P. A. D., Mingione, M., Lipsitt, J. M., Batteate, C., Jerrett, M., & Banerjee, S. (2023) · The Annals of Applied Statistics · doi:10.1214/23-aoas1742 · Cited by 8
“Among various metrics, we take the instantaneous body vector Magnitude of Acceleration (MAG) as the primary endpoint of our analysis [van Hees et al., 2011, White et al., 2016, Doherty et al., 2017].”
MethodChen, X., Zhou, M., Wang, J., Liu, M., Zhu, C., Wu, C., Dong, M., Liu, Y., Ai, S., Feng, H., et al. (2024) · General Hospital Psychiatry · doi:10.1016/j.genhosppsych.2024.08.005 · Cited by 4
Patterns of physical activity in hunter-gatherer children compared with US and UK children
Kretschmer, L., Dyble, M., Chaudhary, N., Bann, D., & Salalι, G. D. (2025) · Scientific Reports · doi:10.1038/s41598-024-81326-w · Cited by 9
Mendt, S., Zout, G., Rabuffetti, M., Gunga, H., Bunker, A., Barteit, S., & Maggioni, M. A. (2025) · Frontiers in Physiology · doi:10.3389/fphys.2025.1491401 · Cited by 5
“The same applies to EE GENEActiv , where acceleration data from GENEActiv was used to estimate EE using a prediction formula for physical activity energy expenditure (White et al., 2016).”
InfluentialMeasurement of Physical Activity by Shoe-Based Accelerometers—Calibration and Free-Living Validation
Fridolfsson, J., Arvidsson, D., & Grau, S. (2021) · Sensors · doi:10.3390/s21072333 · Cited by 4
“The calibration of the wrist output was performed using free-living data, with a multisensory solution combining a trunk positioned accelerometer and heart rate monitoring as reference [22].”
MethodFarina, N., Hughes, L., Thomas, S., Lowry, R., & Banerjee, S. (2021) · Journal of Aging and Physical Activity · doi:10.1123/japa.2021-0189 · Cited by 6
Physical Activity Patterns Within Dementia Care Dyads
Farina, N., Ardle, R. M., Lowry, R., & Banerjee, S. (2024) · Journal of Aging and Physical Activity · doi:10.1123/japa.2023-0078 · Cited by 4
“The device has previously been shown to be valid measure of physical activity and sedentary time (Pavey et al., 2016; White et al., 2016) and is commonly used in older adult populations (Broekhuizen et al., 2016; Ramires et al., 2017; Rowlands et al., 2014).”
Ellingson, L. D., Hibbing, P. R., Welk, G. J., Dailey, D. L., Rakel, B. A., Crofford, L. J., Sluka, K. A., & Frey‐Law, L. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0062 · Cited by 4
Song, Y., Wang, Z., Wang, H. T., Sun, G., Gong, B., & Zhang, F. (2025) · Scientific Reports · doi:10.1038/s41598-025-20195-3 · Cited by 3
“Studies have demonstrated that both time-domain and frequency-domain features extracted from acceleration signals can classify the intensity of different physical activities 31–33 .”
Prioreschi, A., Ong, K. K., Rolfe, E. D. L., Westgate, K. L., Micklesfield, L. K., & Brage, S. (2022) · Maternal and Child Health Journal · doi:10.1007/s10995-022-03406-5 · Cited by 3
Self-citationBourne, J. E., Foster, C. E., Forte, C., Aning, J. J., Potter, S., Hart, E. C., & Armstrong, M. E. G. (2023) · Pilot and Feasibility Studies · doi:10.1186/s40814-023-01293-3 · Cited by 3
“These monitors have been validated to assess PA energy expenditure [99].”
BackgroundDunn, R. C., Tamminen, K. A., Kim, J., & Vanderloo, L. M. (2023) · Psychology and Health · doi:10.1080/08870446.2023.2269422 · Cited by 2
“For example, women were found to engage in less PA compared to men in samples from the United states, United Kingdom, Thailand, and India (Arredondo et al., 2016; singh et al., 2021; Thanamee et al., 2017; White et al., 2016).”
Physical activity trajectories and incidence of cardiovascular risk factors: a prospective study
Naoum, N., & Marques-Vidal, P. M. (2025) · Nutrition Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2025.104201 · Cited by 3
He, Z., Sun, Y., Huang, H., Wellens, J., Liu, Y., Dan, L., Ruan, X., Fu, T., Li, Z., Wang, X., et al. (2025) · International Journal of Surgery · doi:10.1097/js9.0000000000003255 · Cited by 4
“The Axivity AX3 device has been validated in a previous study using multi-axis shaking tests and showed equivalent output to GENEActive accelerometer [21] , which has been validated in both laboratory and free-living assessments [ 22 , 23 ] .”
Zhou, T., Su, S., Yuan, C., Jiang, D., Qiu, Y., Xiao, J., Lu, X., Gu, D., & Liu, F. (2026) · Medicine Plus · doi:10.1016/j.medp.2026.100137 · Cited by 2
Energy expenditure and intensity of ritual jumping–dancing in male M aasai
Christensen, D. L., Westgate, K. L., Griffiths, L., Sironga, J., Maro, V. P., Helge, J. W., Larsen, S., Bygbjerg, I. C., Ramaiya, K. L., Jensen, J., et al. (2023) · American Journal of Human Biology · doi:10.1002/ajhb.23907 · Cited by 4
“2-Hz frequency threshold) to derive High-Pass Filtered Vector Magnitude (White et al., 2016).”
BackgroundInfluentialSelf-citation48th European Mathematical Genetics Meeting (EMGM) 2020
Kutalik, Z. (2019) · Human Heredity · doi:10.1159/000507248 · Cited by 1
Device-measured moderate-to-vigorous physical activity and prognosis of inflammatory bowel diseasePreprint
He, Z., Sun, Y., Huang, H., Liu, Y., Dan, L., Ruan, X., Fu, T., Li, Z., Wang, X., Chen, J., et al. (2024) · medRxiv · doi:10.1101/2024.10.30.24316417 · Cited by 2
“24,25 Triaxial acceleration data is collected at 100Hz with a dynamic range of ±8g and extracted after calibration, flagging and resampling, removing gravity and noise, and identifying non-wear periods.”
MethodShim, J., Fleisch, E., & Barata, F. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10781878 · Cited by 2
“We started with an initial list of 140 candidate features based on previous research [3], [9], [10], [11].”
Xu, C., Zhang, Q., Xu, S., Xiao, Y., Zhao, L., Li, T.-J., Guo, W.-J., Zhong, Y., & Chen, H.-T. (2025) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2025-002547 · Cited by 1
Hoepel, S. J. W., Ikram, M. K., Ikram, M. A., Voortman, T., & Luik, A. I. (2025) · Journal of Sleep Research · doi:10.1111/jsr.70166 · Cited by 2
“Activity was categorised into inactive time (< 48 mg), light PA (48–154 mg), and moderate- to-vigorous PA (> 154 mg) (White et al. 2016).”
Wan, Y., McGuigan, P. M., Bilzon, J., & Wade, L. (2026) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2026.106776 · Cited by 2
Li, R., Lei, F., Liu, B., Lin, L., Huang, X., Zhang, X., Liu, W., Sun, T., Cao, Y., Wu, Q., et al. (2026) · Journal of the American Heart Association · doi:10.1161/jaha.125.043217 · Cited by 1
Physische Aktivität bei älteren Menschen mit Augenerkrankungen
Heinemann, M., Welker, S., Holz, F. G., & Finger, R. P. (2018) · Der Ophthalmologe · doi:10.1007/s00347-018-0688-y · Cited by 1
Hauser, R., Harpe, R. D. L., Vollenweider, P., Hullin, R., Vaucher, J., Marques-Vidal, P. M., & Méan, M. (2024) · Preventive Medicine Reports · doi:10.1016/j.pmedr.2024.102743 · Cited by 3
Prioreschi, A., James, D. M., Pearson, R. M., Smith, A., Norris, S. A., & Rennie, K. L. (2025) · Wellcome Open Research · doi:10.12688/wellcomeopenres.23564.1 · Cited by 1
Physical Activity in Adolescents with respect to Movement Quality and Quantity
Weedon, B. D. (2020) · Radar (Oxford Brookes University) · doi:10.24384/381r-t238 · Cited by 3
Dempsey, P., Rowlands, A., Strain, T., Zaccardi, F., Dawkins, N., Razieh, C., Davies, M., Khunti, K., Edwardson, C., Wijndaele, K., et al. (2022) · medRxiv · doi:10.1101/2022.02.23.22271386 · Cited by 1
“We estimated instantaneous PAEE from wrist movement intensity (27), the time integral of which constitutes total volume of activity as PAEE, as validated against the gold-standard criterion of doubly-labelled water (28) (Table S1).”
MethodSelf-citationMina, T. H., Sadhu, N., Low, D. Y., Jain, P., Wang, X., Ng, H. K., van der Es, T., Lim, K., The HELIOS Study team, Elliott, P., et al. (2025) · medRxiv · doi:10.1101/2025.06.18.25329738 · Cited by 1
USOS DE LOS ACELERÓMETROS EN FISIOTERAPIA: UNA REVISIÓN DE LA LITERATURA
Mantilla, J. A. (2017) · Revista Iberoamericana de Ciencias de la Actividad Física y el Deporte · doi:10.24310/riccafd.2017.v6i2.3781 · Cited by 4
“De hecho, los procesos de investigación están optando por la utilización de acelerómetros para la medición de niveles de actividad física con el fin de identificar riesgos cardiovasculares y metabólicos para la salud(20-27).”
BackgroundHarmonisation of Physical Activity Variables by Indirect Validation: A Doubly Labelled Water StudyPreprint
Pearce, M., Bishop, T. R. P., Sharp, S. J., Westgate, K. L., Venables, M., Wareham, N. J., & Brage, S. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/501718
“that of an objective starting measure, two additional AC bridge equations derived from the linear regression of: (6) ACCTRUNK on ACCWRIST; and (7) ACCHR PAEE on ACCWRIST, which were obtained from published work (White et al., 2016).”
MethodSelf-citationZhang, X., Τheodoratou, E., Li, X., Farrington, S. M., Law, P., Broderick, P., Walker, M., Rees, J. M. B., Houlston, R. S., Tomlinson, I. P. M., et al. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/798470
“[49] White T, Westgate K, Wareham NJ, Brage S.”
BackgroundThe next day effects of a normal night's drinking on cognition and human performance
Devenney, L. E. (2019) · Ulster University Research Portal (Ulster University)
Dusfour, G., Mottet, D., Muthalib, M., Laffont, I., & Bakhti, K. (2021) · Research Square · doi:10.21203/rs.3.rs-845425/v1
“In particular, we think 373 of the quantification of physical activity via the ENMO (Euclidean Norm Minus One) indicator 374 [White et al, 2016] as well as the quantification of smoothness during a functional movement 375 via the study of [Melendez-Calderon et al, 2021] 376 The wrist actimetry…”
MethodMarshall, Z. A. (2021) · Cronfa (Swansea University) · doi:10.23889/suthesis.58608
Assessment of free-living energy expenditure
Chowdhury, E. A., Peacock, O. J., & Thompson, D. (2022) · Routledge eBooks · doi:10.4324/9781003045267-18
(2019) · PeerJ · doi:10.7287/peerj.7973v0.1/reviews/1
“wrist-mounted device can be used to estimate EE (Welch et al., 2013; White et al., 2016; Sirichana et al., 2017), recent research has demonstrated that waist-mounted devices worn closer to the body centre of mass can provide EE estimates that are more accurate than”
MethodFlammer, F., Paraschiv-Ionescu, A., & Marques-Vidal, P. M. (2024) · BMC Cardiovascular Disorders · doi:10.1186/s12872-024-03755-9 · Cited by 1
“Raw accelerometer data was analysed using the software GGIR version 1.5-9 running on R [16], using the acceleration thresholds proposed by White et al. [17] to define LPA ( ≥ 85 and < 181 milli-g), MPA ( ≥ 181 and < 437 milli-g) and VPA ( ≥ 437 milli-g).”
MethodInfluentialVonLanthen, G., & Marques-Vidal, P. M. (2024) · BMJ Open · doi:10.1136/bmjopen-2023-078929 · Cited by 1
“…performed on the raw accelerometry data using the R-package GGIR V.1.5-9 (http://cran. r-project.org) 15 with the thresholds defined by White et al , 16 that is, an acceleration between 85 and 180 milli-g to define light PA, between 181 and 437 milli-g to define MPA and >437 milli-g to define VPA.”
InfluentialCao, Y., Lei, F., Zhang, X., Liu, W., Huang, X., Sun, T., Lin, L., Wan, J., & Liu, H. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5361476
Godkin, F. E., Ooteghem, K. V., Beyer, K. B., Weber, K. S., Cornish, B. F., Tang, A., Martens, K. A. E., & McIlroy, W. E. (2025) · Digital Health · doi:10.1177/20552076251367506 · Cited by 3
Wu, X., Yang, W., Li, Y., Zhang, L., Li, C.-Y., Xu, W., & Ma, F. (2025) · European Journal of Neuroscience · doi:10.1111/ejn.70325
“Wrist-worn accelerometers have been validated against established measures of physical activity energy expenditure (White et al. 2016).”
Tasheva, P., Kraege, V., Vollenweider, P., Roulet, G., Méan, M., & Marques-Vidal, P. M. (2020) · Figshare · doi:10.6084/m9.figshare.13047105
Dusfour, G., Mottet, D., Muthalib, M., Laffont, I., & Bakhti, K. (2023) · Figshare · doi:10.6084/m9.figshare.22715362
Tasheva, P., Kraege, V., Vollenweider, P., Roulet, G., Méan, M., & Marques-Vidal, P. M. (2020) · Figshare · doi:10.6084/m9.figshare.13047099
Pearce, M., Strain, T., Kim, Y., Sharp, S. J., Westgate, K. L., Wijndaele, K., Gonzales, T. I., Wareham, N. J., & Brage, S. (2020) · Figshare · doi:10.6084/m9.figshare.11992560
Self-citationBourne, J. E., Foster, C., Forte, C., Aning, J., Potter, S., Hart, E. C., & Armstrong, M. E. G. (2023) · Figshare · doi:10.6084/m9.figshare.22688802
Bourne, J. E., Foster, C., Forte, C., Aning, J., Potter, S., Hart, E. C., & Armstrong, M. E. G. (2023) · Figshare · doi:10.6084/m9.figshare.22688799
Collaud, S., Touilloux, B., von Garnier, C., Marques-Vidal, P. M., & Kraege, V. (2024) · Figshare · doi:10.6084/m9.figshare.25566238
Lin, F., Shi, Y., Song, W., Weng, Y., Zou, X., Chen, X., Zheng, J., Chen, K., Ye, Q., Wu, X., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26759525
Lin, F., Shi, Y., Song, W., Weng, Y., Zou, X., Chen, X., Zheng, J., Chen, K., Ye, Q., Wu, X., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26759534
Lin, F., Shi, Y., Song, W., Weng, Y., Zou, X., Chen, X., Zheng, J., Chen, K., Ye, Q., Wu, X., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26759528
Tasheva, P., Kraege, V., Vollenweider, P., Roulet, G., Méan, M., & Marques-Vidal, P. M. (2020) · Figshare · doi:10.6084/m9.figshare.13047108
Collaud, S., Touilloux, B., von Garnier, C., Marques-Vidal, P. M., & Kraege, V. (2024) · Figshare · doi:10.6084/m9.figshare.26703823
Lin, F., Shi, Y., Song, W., Weng, Y., Zou, X., Chen, X., Zheng, J., Chen, K., Ye, Q., Wu, X., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26759531
Tasheva, P., Kraege, V., Vollenweider, P., Roulet, G., Méan, M., & Marques-Vidal, P. M. (2020) · Figshare · doi:10.6084/m9.figshare.13047102
Collaud, S., Touilloux, B., von Garnier, C., Marques-Vidal, P. M., & Kraege, V. (2024) · Figshare · doi:10.6084/m9.figshare.25566404
Flammer, F., Paraschiv-Ionescu, A., & Marques-Vidal, P. M. (2024) · Figshare · doi:10.6084/m9.figshare.25210585
Association of Physical Activity and Obesity With the Risk of Degenerative Cervical Myelopathy
Yakdan, S. M., Yahanda, A. T., Benedict, B. C., Wang, J., LIlly, D., Hammo, A., Arkam, F., Hafez, D., Badhiwala, J. H., Steinmetz, M. P., et al. (2026) · Neurosurgery · doi:10.1227/neu.0000000000004090 · Cited by 2
Li, L., Xu, M., Wu, L., Hu, Z. L., Liu, L., Zhou, L., Zhao, M., Xiong, Y., Zhang, Z., Zheng, L., et al. (2026) · The Journal of Prevention of Alzheimer s Disease · doi:10.1016/j.tjpad.2026.100603
“The overall mean acceleration (vector magnitude, derived from 5-second epoch aggregation of raw data) served as the measure of global PA volume [21].”
Dong, H., Han, C., Chen, Y., Zhang, Z., Xu, X., Wang, Y., Zhao, Z., Gao, X., & Sun, L. (2026) · Nutrition Journal · doi:10.1186/s12937-026-01358-y
“Physical activity energy expenditure (PAEE) was estimated using a previously published equation [27] based on ENMO derived using GGIR.”
Learning From Decoupled Sensor Axes: Enhancing Cross-Dataset Human Activity Recognition
Tang, Z.-P., He, S.-B., Wang, C., Chen, Q., Pan, J., & Gu, C.-J. (2026) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2026.3723993
Alves, C. P. D. L., Costa, E. C., Bielemann, R. M., González, M. C., Tomasi, E., Ekelund, U., & Crochemore‐Silva, I. (2026) · Journal of Aging and Physical Activity · doi:10.1123/japa.2025-0322
Laitinen, E., Soininen, S., Leppänen, M. H., Lintu, N., Bond, B., Kähönen, M. A. P., Laitinen, T. P., Luukkainen, N., Waller, K. L., Lakka, T. A., et al. (2026) · Pediatric Exercise Science · doi:10.1123/pes.2025-0177
Metadata
- Authors
- White, T., Westgate, K., Wareham, N. J., & Brage, S.
- Affiliations
- University of Cambridge (GB)
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2016-12-09
- Volume
- 11
- Issue
- 12
- Pages
- e0167472
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC5147924
- OpenAlex
- W2560176117
- Cited by
- 169
- References
- 19
- Citations by year
- 2026: 9 · 2025: 16 · 2024: 24 · 2023: 24 · 2022: 15 · 2021: 13 · 2020: 23 · 2019: 24 · 2018: 12 · 2017: 9
- FWCI
- 11.98
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Apollo (University of Cambridge) (submittedVersion, cc-by)
- Apollo (cc-by)
- Funders
- Medical Research Council (MC_UU_12015/3)
- MedImmune (N/A)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Obesity, Physical Activity, Diet
- Keywords
- physical activity energy expenditure, wrist-worn accelerometers, free-living physical activity, accelerometer calibration, heart rate monitoring, combined sensor, treadmill exercise testing, body mass index
- MeSH terms
- Adult, Algorithms, Diabetes Mellitus, Energy Metabolism, Exercise Test, Female, United Kingdom, Heart Rate, Humans, Male, Middle Aged, Monitoring, Physiologic, Obesity, Prospective Studies, Wrist, Reproducibility of Results, Exercise, Body Mass Index, Linear Models, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.