Home detection of freezing of gait using support vector machines through a single waist-worn triaxial accelerometer
Open accessThe DOI matches its Crossref record; 70 of the 72 references it cites were found in a registry or an index.
Abstract
Among Parkinson's disease (PD) symptoms, freezing of gait (FoG) is one of the most debilitating. To assess FoG, current clinical practice mostly employs repeated evaluations over weeks and months based on questionnaires, which may not accurately map the severity of this symptom. The use of a non-invasive system to monitor the activities of daily living (ADL) and the PD symptoms experienced by patients throughout the day could provide a more accurate and objective evaluation of FoG in order to better understand the evolution of the disease and allow for a more informed decision-making process in making adjustments to the patient's treatment plan. This paper presents a new algorithm to detect FoG with a machine learning approach based on Support Vector Machines (SVM) and a single tri-axial accelerometer worn at the waist. The method is evaluated through the acceleration signals in an outpatient setting gathered from 21 PD patients at their home and evaluated under two different conditions: first, a generic model is tested by using a leave-one-out approach and, second, a personalised model that also uses part of the dataset from each patient. Results show a significant improvement in the accuracy of the personalised model compared to the generic model, showing enhancement in the specificity and sensitivity geometric mean (GM) of 7.2%. Furthermore, the SVM approach adopted has been compared to the most comprehensive FoG detection method currently in use (referred to as MBFA in this paper). Results of our novel generic method provide an enhancement of 11.2% in the GM compared to the MBFA generic model and, in the case of the personalised model, a 10% of improvement with respect to the MBFA personalised model. Thus, our results show that a machine learning approach can be used to monitor FoG during the daily life of PD patients and, furthermore, personalised models for FoG detection can be used to improve monitoring accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“The best results reported in similar studies using a single sensor on a free-living environment with LOSO evaluation are 79.03% and 74.67% [59] and 84.49% on sensitivity and 85.83 on specificity [64].”
From Deep Learning Approaches for Detecting Freezing of Gait in Parkinson’s Disease Patients through On-Body Acceleration Sensors (2020) · cites this paper as [59]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The data are composed of acceleration signals from 21 patients (3 women and 18 men) with FOG symptoms and a mean age of 69 years.”
From Deep Learning Approaches for Detecting Freezing of Gait in Parkinson’s Disease Patients through On-Body Acceleration Sensors (2020) · cites this paper as [59]
In the citing paper
“All data collection was carried out at the patients’ homes.”
From Deep Learning Approaches for Detecting Freezing of Gait in Parkinson’s Disease Patients through On-Body Acceleration Sensors (2020) · cites this paper as [59]
In the citing paper
“The data were collected through a wearable IMU located at the waist, in both ON and OFF states.”
From Deep Learning Approaches for Detecting Freezing of Gait in Parkinson’s Disease Patients through On-Body Acceleration Sensors (2020) · cites this paper as [59]
In the citing paper
“The data used for testing the proposed methods in FOG detection were collected for the article [59].”
From Deep Learning Approaches for Detecting Freezing of Gait in Parkinson’s Disease Patients through On-Body Acceleration Sensors (2020) · cites this paper as [59]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Nature of Statistical Learning Theory
Vapnik, V. N. (1995) · doi:10.1007/978-1-4757-2440-0 · Cited by 39,138
The Timed “Up & Go”: A Test of Basic Functional Mobility for Frail Elderly Persons
Podsiadlo, D., & Richardson, S. (1991) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1991.tb01616.x · Cited by 14,418
Parkinsonism: onset, progression, and mortality
Hoehn, M. M., & Yahr, M. D. (1967) · Neurology · doi:10.1212/wnl.17.5.427 · Cited by 12,107
Hughes, A. J., Daniel, S. E., Kilford, L., & Lees, A. J. (1992) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.55.3.181 · Cited by 10,378
Overdependence on degraded gist memory in Alzheimer's disease.
Gallo, D. A., Shahid, K. R., Olson, M. A., Solomon, T. M., Schacter, D. L., & Budson, A. E. (2006) · Neuropsychology · doi:10.1037/0894-4105.20.6.625 · Cited by 4,732
Bloem, B. R., Hausdorff, J. M., Visser, J. E., & Giladi, N. (2004) · Movement Disorders · doi:10.1002/mds.20115 · Cited by 1,297
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058
Human motion tracking for rehabilitation-A survey
Zhou, H., & Hu, H. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.001 · Cited by 813 · cited 1×
“This data is resampled at 40Hz since this frequency has been shown to be enough to analyse human movements [65] and it is sufficient to analyse the frequencies obtained during FoG episodes [20].”
Construction of freezing of gait questionnaire for patients with Parkinsonism
Giladi, N., Shabtai, H., Simon, E. S., Biran, S., Tal, J., & Korczyn, A. D. (2000) · Parkinsonism & Related Disorders · doi:10.1016/s1353-8020(99)00062-0 · Cited by 790 · cited 1×
“Medication effect has a strong influence regarding the motor response in PD patients with FoG [11,14,63], thus, tests were performed with and without medication.”
BackgroundNajafi, B., Aminian, K., Paraschiv-Ionescu, A., Loew, F., Bula, C. J., & Robert, P. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.812189 · Cited by 762
Research works printed but not linked: 3
- Samà A, Perez-Lopez C, Rodriguez-Martin D, Cabestany J, Moreno JM, Rodriguez-Molinero A. A Heterogeneous Database for Movement Knowledge Extraction in Parkinson ‘ s Disease. European Symposium on Artificial Neural Networks, Computational Intelligence and Machine Learning. 2013.
- Rodríguez-Martín D, Samà A, Pérez-López C, Català A, Cabestany J, Rodríguez-Molinero A. Posture Detection with waist-worn Accelerometer: An application to improve Freezing of Gait detection in Parkinson ‘ s disease patients. European Conference on Ambient Assisted Living. Eindhoven; 2014. pp. 1–6.
- Takač B, Català A, Rodríguez Martín D, van der Aa N, Chen W, Rauterberg M. Position and Orientation Tracking in a Ubiquitous Monitoring System for Parkinson Disease Patients With Freezing of Gait Symptom. JMIR mhealth uhealth. JMIR mhealth and uhealth; 2013; 1: e14 10.2196/mhealth.2539 25098265 PMC4114461 · DOI
Cited by
Halilaj, E., Rajagopal, A., Fiterau, M., Hicks, J. L., Hastie, T. J., & Delp, S. L. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.09.009 · Cited by 460
Camps, J., Samà, A., Martín, M., Rodríguez-Martín, D., Pérez-López, C., Moreno Arostegui, J. M., Cabestany, J., Català, A., Alcaine, S., Mestre, B., et al. (2018) · Knowledge-Based Systems · doi:10.1016/j.knosys.2017.10.017 · Cited by 224
Self-citationLonini, L., Dai, A., Shawen, N., Simuni, T., Poon, C., Shimanovich, L., Daeschler, M., Ghaffari, R., Rogers, J. A., & Jayaraman, A. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0071-z · Cited by 209
Wearable-Sensor-Based Detection and Prediction of Freezing of Gait in Parkinson’s Disease: A Review
Pardoel, S., Kofman, J., Nantel, J., & Lemaire, E. D. (2019) · Sensors · doi:10.3390/s19235141 · Cited by 201
“Gait-based features such as cadence [49], stride duration [35,50,71], and step length [35,71,77], as well as statistical features including mean [42,45,52,54,57,58,71,74,75,77,80,81,95], standard deviation [42, 45,52,54,57,58,71,74,75,77,80,81,88,89,95,98], and root mean square [45,48,54,78,86] are also calculated fro…”
BackgroundMethodInfluentialArtificial intelligence for assisting diagnostics and assessment of Parkinson’s disease—A review
Belić, M., Bobić, V., Badža, M., Šolaja, N., Đurić-Jovičić, M., & Kostić, V. S. (2019) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2019.105442 · Cited by 194
Shirejini, S. Z., & Inci, F. (2022) · Biotechnology Advances · doi:10.1016/j.biotechadv.2021.107814 · Cited by 187
Measuring freezing of gait during daily-life: an open-source, wearable sensors approach
Mancini, M., Shah, V. V., Stuart, S., Curtze, C., Horak, F. B., Safarpour, D., & Nutt, J. G. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00774-3 · Cited by 182
An update on adaptive deep brain stimulation in Parkinson's disease
Habets, J. G. V., Heijmans, M., Kuijf, M. L., Janssen, M. L. F., Temel, Y., & Kubben, P. L. (2018) · Movement Disorders · doi:10.1002/mds.115 · Cited by 169
Clinical and methodological challenges for assessing freezing of gait: Future perspectives
Mancini, M., Bloem, B. R., Horak, F. B., Lewis, S. J. G., Nieuwboer, A., & Nonnekes, J. (2019) · Movement Disorders · doi:10.1002/mds.27709 · Cited by 173
“4% specificity using a machine learning approach trained on 21 patients with Parkinson’s disease.(46) However, this approach has not been validated in a new population, so the performance of this algorithm in another group of people with PD remains unclear.”
MethodOverview on wearable sensors for the management of Parkinson’s disease
Moreau, C., Rouaud, T., Grabli, D., Bénatru, I., Rémy, P., Marquès, A., Drapier, S., Mariani, L., Roze, E. F., Devos, D., et al. (2023) · npj Parkinson s Disease · doi:10.1038/s41531-023-00585-y · Cited by 205
“The ability of the system to identify FoG has a sensitivity of 79% and a speci fi city of 75% compared to physician-based observation at home 65 .”
ResultTăuţan, A.-M., Ionescu, B. E., & Santarnecchi, E. (2021) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2021.102081 · Cited by 174
Sigcha, L., Borzì, L., Amato, F., Rechichi, I., Ramos-Romero, C. A., Cardenas, A. J. A., Gascó, L., & Olmo, G. (2023) · Expert Systems with Applications · doi:10.1016/j.eswa.2023.120541 · Cited by 172
Wearables for independent living in older adults: Gait and falls
Godfrey, A. (2017) · Maturitas · doi:10.1016/j.maturitas.2017.03.317 · Cited by 105
Sigcha, L., Costa, N., Pavón, I., Costa, S., Arezes, P., López, J. M., & De Arcas, G. (2020) · Sensors · doi:10.3390/s20071895 · Cited by 126
“In this methodology, only the data of one patient is used in training and testing in order to make personalized detection models [44,59,64].”
BackgroundMethodInfluentialEmerging role of extracellular vesicles in musculoskeletal diseases
Murphy, C., Withrow, J., Hunter, M., Liu, Y., Tang, Y. L., Fulzele, S., & Hamrick, M. W. (2018) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2017.09.006 · Cited by 123
Palmerini, L., Rocchi, L., Mazilu, S., Gazit, E., Hausdorff, J. M., & Chiari, L. (2017) · Frontiers in Neurology · doi:10.3389/fneur.2017.00394 · Cited by 116
“The most frequent approach for the detection of FOG events is based on the fact that during FOG the acceleration signals recorded by inertial sensors show a pattern of high frequency movements (mostly given by the trembling behavior of the legs) (4, 6–15).”
Shalin, G., Pardoel, S., Lemaire, E. D., Nantel, J., & Kofman, J. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00958-5 · Cited by 120
“Compared to SVM models [19, 34] and a 1D CNN model [21], the new 2-layer LSTM model needs less computer memory (Table 14).”
MethodInfluentialDin, S. D., Kirk, C., Yarnall, A. J., Rochester, L., & Hausdorff, J. M. (2021) · Journal of Parkinson s Disease · doi:10.3233/jpd-202471 · Cited by 137
Monitoring Motor Symptoms During Activities of Daily Living in Individuals With Parkinson's Disease
Thorp, J. E., Adamczyk, P. G., Ploeg, H., & Pickett, K. A. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.01036 · Cited by 114
“Better results were found using patient-specific models (52).”
BackgroundMethodInfluentialToward a Wearable System for Predicting Freezing of Gait in People Affected by Parkinson's Disease
Demrozi, F., Bacchin, R., Tamburin, S., Cristani, M., & Pravadelli, G. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2952618 · Cited by 86
“5, Naive Bayes, k-NN, Logistic Regression and SupportVectorMachine (SVM) [18]–[20] orDeepLearning approaches [11], [21].”
BackgroundVision-Based Freezing of Gait Detection With Anatomic Directed Graph Representation
Hu, K., Wang, Z., Mei, S., Martens, K. A. E., Yao, T., Lewis, S. J. G., & Feng, D. D. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2923209 · Cited by 91
Aich, S., Pradhan, P. M., Park, J., Sethi, N. K., Vathsa, V. S. S., & Kim, H. (2018) · Sensors · doi:10.3390/s18103287 · Cited by 98
“[29] have extracted features from the data generated from the wearable accelerometer, and used them for the detection of FoG.”
BackgroundMethodInfluentialLong short term memory based patient-dependent model for FOG detection in Parkinson's disease
Ashour, A. S., El-Attar, A., Dey, N., Elkader, H. A., & El-Naby, M. M. A. (2019) · Pattern Recognition Letters · doi:10.1016/j.patrec.2019.11.036 · Cited by 85
Monitoring Parkinson’s disease symptoms during daily life: a feasibility study
Heijmans, M., Habets, J., Herff, C., Aarts, J., Stevens, A., Kuijf, M. L., & Kubben, P. (2019) · npj Parkinson s Disease · doi:10.1038/s41531-019-0093-5 · Cited by 95
Luis-Martínez, R., Monje, M. H. G., Antonini, A., Sánchez‐Ferro, Á., & Mestre, T. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.575975 · Cited by 92
“…cardinal motor features (mainly for bradykinesia and tremor) (18, 19) and (ii) the detection of complications that appear throughout the disease (e.g., the exact quantification of on vs. off states and motor fluctuations or the freezing of gait and falls in a home environment) (20, 21) ( Figure 2 ).”
BackgroundMohammadian Rad, N., Van Laarhoven, T., Furlanello, C., & Marchiori, E. (2018) · Sensors · doi:10.3390/s18103533 · Cited by 76
Didelphis spp. opossums and their parasites in the Americas: A One Health perspective
Bezerra‐Santos, M. A., Ramos, R. A. N., Campos, A. K., Dantas‐Torres, F., & Otranto, D. (2021) · Parasitology Research · doi:10.1007/s00436-021-07072-4 · Cited by 94
Borzì, L., Sigcha, L., Rodríguez-Martín, D., & Olmo, G. (2022) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2022.102459 · Cited by 80
Self-citationGupta, C. L., Blum, S. E., Kattusamy, K., Daniel, T., Druyan, S., Shapira, R., Krifucks, O., Zhu, Y., Zhou, X., Su, J., et al. (2021) · Microbiome · doi:10.1186/s40168-021-01136-4 · Cited by 84
Assessing inertial measurement unit locations for freezing of gait detection and patient preference
O’Day, J. J., Lee, M. R., Seagers, K. A., Hoffman, S. L., Jih-Schiff, A., Kidziński, Ł., Delp, S. L., & Bronte-Stewart, H. M. (2022) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-022-00992-x · Cited by 88
“Studies have also probed a variety of sensor locations including the feet, shanks/ankles, knees, thighs, lower back, waist, chest, head, forearms and wrists [17, 18].”
BackgroundDeep brain stimulation: a review of the open neural engineering challenges
Vissani, M., Isaias, I. U., & Mazzoni, A. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abb581 · Cited by 81
“127 580–7 [260] Rodríguez-Martín D et al 2017 Home detection of freezing of gait using support vector machines through a single waist-worn triaxial accelerometer PLOS One 12 e0171764 [261] Hasan H, Athauda D S, Foltynie T and Noyce A J 2017 Technologies assessing limb bradykinesia in parkinson’s disease J.”
MethodLu, R., Xu, Y., Li, X., Fan, Y., Zeng, W., Tan, Y., Ren, K., Chen, W., & Cao, X. (2020) · Parkinson s Disease · doi:10.1155/2020/4693019 · Cited by 95
“Many of such studies show that sensor devices have higher sensitivity when detecting shorter FOG events, with an accuracy of >90% [32, 33, 79].”
BackgroundSystematic Review on Machine-Learning Algorithms Used in Wearable-Based eHealth Data Analysis
Site, A., Nurmi, J., & Lohan, E. S. (2021) · IEEE Access · doi:10.1109/access.2021.3103268 · Cited by 82
Rodríguez-Martín, D., Cabestany, J., Pérez‐López, C., Pie, M., Calvet, J., Samà, A., Capra, C., Catalá, A., & Rodríguez‐Molinero, A. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2022.912343 · Cited by 74
“The second microcontroller is the STM32F415 microcontroller, which has a CortexTM M4 core (with a floating-point unit) running at 168 MHz for operating complex mathematical models, such as the SVM classifiers, or the signal filtering and featuring required by the described algorithms (129).”
BackgroundMethodInfluentialSelf-citationReches, T., Dagan, M., Herman, T., Gazit, E., Gouskova, N., Giladi, N., Manor, B. D., & Hausdorff, J. M. (2020) · Sensors · doi:10.3390/s20164474 · Cited by 73
Janeh, O., Fründt, O., Schönwald, B., Gulberti, A., Buhmann, C., Gerloff, C. P., Steinicke, F., & Pötter‐Nerger, M. (2019) · Cells · doi:10.3390/cells8050419 · Cited by 73
“Other inclusion criteria include no severe dementia (Montreal Cognitive Assessment MoCA [20] > 21, this cut-off has also been used in Reference [21]) as dementia can be associated with gait disturbances [22], Giladi’s Freezing of Gait Questionnaire [23] with a score > 6 (this cut-off has been used in [24]), no severe…”
Review—Emerging Portable Technologies for Gait Analysis in Neurological Disorders
Salchow-Hömmen, C., Skrobot, M., Jochner, M. C. E., Schauer, T., Kühn, A. A., & Wenger, N. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.768575 · Cited by 73
“Various sensor-based methods have been developed to objectively measure FoG in terms of number of episodes and episode duration (Moore et al., 2008; Rodrguez-Martn et al., 2017; Silva de Lima et al., 2017; Suppa et al., 2017; Pardoel et al., 2019).”
MethodStalin, S., Maheshwary, P., Shukla, P. K., Maheshwari, M., Gour, B., & Khare, A. (2019) · Journal of Medical Systems · doi:10.1007/s10916-019-1389-z · Cited by 62
Haq, A. U., Li, J., Agbley, B. L. Y., Mawuli, C. B., Ali, Z., Nazir, S., & Din, S. U. (2022) · Expert Systems with Applications · doi:10.1016/j.eswa.2022.118045 · Cited by 73
Arami, A., Poulakakis-Daktylidis, A., Tai, Y., & Burdet, E. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2933626 · Cited by 60
“In [31], signals from a single accelerometer worn at the waist classified using support vector machine (SVM) classifiers could detect”
BackgroundGraph Fusion Network-Based Multimodal Learning for Freezing of Gait Detection
Hu, K., Wang, Z., Martens, K. A. E., Hagenbuchner, M., Bennamoun, M., Tsoi, A. C., & Lewis, S. J. G. (2021) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2021.3105602 · Cited by 67
Shokrpour, S., MoghadamFarid, A., Abkenar, S. B., Kashani, M. H., Akbari, M., & Sarvizadeh, M. (2025) · npj Parkinson s Disease · doi:10.1038/s41531-025-01025-9 · Cited by 76
Salomon, A., Gazit, E., Ginis, P., Urazalinov, B., Takoi, H., Yamaguchi, T., Goda, S., Lander, D., Lacombe, J., Sinha, A. K., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-49027-0 · Cited by 58
“Previous studies using similar sensor data have shown somewhat similar performances 33,34,39 – 42 , tending to pre-sent a slightly different balance of sensitivity and speci fi city (here, sensitivity was lower and speci fi city was higher).”
BackgroundMethodResultSigcha, L., Borzì, L., Pavón, I., Costa, N., da Costa, S. P., Arezes, P., López, J. M., & de Arcas, G. (2022) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2022.105482 · Cited by 64
A Waist-Worn Inertial Measurement Unit for Long-Term Monitoring of Parkinson’s Disease Patients
Rodríguez-Martín, D., Pérez‐López, C., Samà, A., Catalá, A., Arostegui, J. M. M., Cabestany, J., Mestre, B., Alcaine, S., Prats, A., Crespo, M. C., et al. (2017) · Sensors · doi:10.3390/s17040827 · Cited by 66
“2nd order filters [3,41,60–64] All Sample calculation Mean 3 accelerometer axes [3,41,60,63,64] Brady, FoG, Gait Window output Standard deviation [3,41,60,63,64] Brady, FoG, Gait Window output STFT—Band 1 [3,41,61–64] Gait, Dysk, Brady Window output STFT—Band 2 [3,41,61–64] Gait, Dysk, Brady Window output STFT—dyskine…”
BackgroundMethodSelf-citationQuantifying Motor Impairment in Movement Disorders
FitzGerald, J. J., Lu, Z., Jareonsettasin, P., & Antoniades, C. A. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00202 · Cited by 57
“…walking, exercise, and cycling activities during rehabilitation of stroke patients (Dobkin et al., 2011), and analysis of belt-worn accelerometer data using support vector machines to look for signs of freezing of gait (Rodriguez-Martin et al., 2017) and dyskinesia (Perez-Lopez et al., 2016) in PD.”
MethodHuang, T., Li, M., & Huang, J. (2023) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2023.1119956 · Cited by 58
Rovini, E., Maremmani, C., & Cavallo, F. (2019) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2018.0035 · Cited by 55
Home monitoring of motor fluctuations in Parkinson’s disease patients
Borzì, L., Varrecchia, M., Olmo, G., Artusi, C. A., Fabbri, M., Rizzone, M. G., Romagnolo, A., Zibetti, M., & Lopiano, L. (2019) · Journal of Reliable Intelligent Environments · doi:10.1007/s40860-019-00086-x · Cited by 54
Parkinson’s disease diagnosis using deep learning: A bibliometric analysis and literature review
Abumalloh, R. A., Nilashi, M., Samad, S., Ahmadi, H., Alghamdi, A., Alrizq, M., & AlYami, S. S. (2024) · Ageing Research Reviews · doi:10.1016/j.arr.2024.102285 · Cited by 53
Kobsar, D., & Ferber, R. (2018) · Sensors · doi:10.3390/s18092828 · Cited by 57
“Used in conjunction with wearable sensors collecting data over hundreds or thousands of individual gait cycles, these subject-specific models have demonstrated the ability to outperform group-based models in identifying clinically relevant changes in gait [18,19].”
BackgroundWu, P., Cao, B., Liang, Z., & Wu, M. (2023) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2023.1191378 · Cited by 43
Triggers for freezing of gait in individuals with Parkinson’s disease: a systematic review
Conde, C. I., Lang, C., Baumann, C. R., Easthope, C. A., Taylor, W. R., & Ravi, D. K. (2023) · Frontiers in Neurology · doi:10.3389/fneur.2023.1326300 · Cited by 53
“Execution of the Ziegler course included a “Stand Up and Go test crossing through a doorway and then, turning back” (66).”
MethodHajati, N., & Řežaeizadeh, A. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3073440 · Cited by 45
“We define The significant features extracted from each window are as stated in the following [35].”
Predicting Freezing of Gait in Parkinsons Disease Patients Using Machine Learning
Orphanidou, N. K., Hussain, A., Keight, R., Lishoa, P., Hind, J., & Al-Askar, H. (2018) · 2018 IEEE Congress on Evolutionary Computation (CEC) · doi:10.1109/cec.2018.8477909 · Cited by 39
“Most of the studies focused on the detection of FoG and tried to validate the differentiation of walking against FoG [24], [27]–[29].”
BackgroundFiltjens, B., Ginis, P., Nieuwboer, A., Slaets, P., & Vanrumste, B. (2022) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-022-01025-3 · Cited by 52
Recognition of freezing of gait in Parkinson’s disease based on combined wearable sensors
Ren, K., Chen, Z., Ling, Y., & Zhao, J. (2022) · BMC Neurology · doi:10.1186/s12883-022-02732-z · Cited by 42
“1 FI a Ratio of [3, 8] Hz power (freezing zone) to [0.”
BackgroundMethodInfluentialA method for modelling coastal erosion risk: the example of Scotland
Fitton, J. M., Hansom, J. D., & Rennie, A. F. (2018) · Natural Hazards · doi:10.1007/s11069-017-3164-0 · Cited by 38
Tahir, A., Ahmad, J. E., Shah, S. A., Morison, G., Skelton, D. A., Larijani, H., Abbasi, Q. H., Imran, M. A., & Gibson, R. M. (2019) · Electronics · doi:10.3390/electronics8121433 · Cited by 40
“[47] Wearable devices Accelerometer 21 Support vector machine 88.”
Detecting motor symptom fluctuations in Parkinson’s disease with generative adversarial networks
Ramesh, V., & Bilal, E. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00674-x · Cited by 37
“Another similar study by Rodriguez-Martin et al. used support vector machines (SVMs) to detect FoG events from a single waist-worn sensor at home, to address the lack of FoG events that occur during clinical visits 2 – 4 .”
BackgroundMethodResultInfluentialIMU-Based Monitoring for Assistive Diagnosis and Management of IoHT: A Review
Bo, F., Yerebakan, M., Dai, Y., Wang, W., Li, J., Hu, B., & Gao, S. (2022) · Healthcare · doi:10.3390/healthcare10071210 · Cited by 35
“Several ML strategies are adopted in detecting FoG events, such as SVM with RBF kernel [43,47], CNN [81,83], and RNN [24], all of which require expert clinicians to label using video recordings and supervised training.”
MethodDeep Learning for Detecting Freezing of Gait Episodes in Parkinson’s Disease Based on Accelerometers
Camps, J., Samà, A., Martín, M., Rodríguez-Martín, D., Pérez‐López, C., Alcaine, S., Mestre, B., Prats, A., Crespo, M. C., Cabestany, J., et al. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-59147-6_30 · Cited by 35
“[19] presented an extension of [18] and [17].”
BackgroundMethodSelf-citationPinto, C., Schuch, C. P., Balbinot, G. C., Salazar, A. P., Hennig, E. M., Kleiner, A. F. R., & Pagnussat, A. S. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0579-8 · Cited by 39
“Although machine learning methods are a better standard for freeze detection, it is necessary to visualize a freeze detection from a synchronized video recording, and to train the computer algorithm to detect further freeze events throughout the entire record (reviewed in [28, 29]).”
MethodA Multi-Modal Analysis of the Freezing of Gait Phenomenon in Parkinson’s Disease
Mesin, L., Porcu, P., Russu, D., Farina, G., Borzì, L., Zhang, W., Guo, Y., & Olmo, G. (2022) · Sensors · doi:10.3390/s22072613 · Cited by 33
“, legs [28], wrist [29], waist [30]) for FOG detection [29,31] and prediction [28,29,32].”
BackgroundHabib, Z., Mughal, M. A., Khan, M. A., & Shabaz, M. (2023) · Alexandria Engineering Journal · doi:10.1016/j.aej.2023.11.075 · Cited by 36
Digital Phenotyping in Clinical Neurology
Gupta, A. S. (2022) · Seminars in Neurology · doi:10.1055/s-0041-1741495 · Cited by 36
An Interpretable Deep Learning Optimized Wearable Daily Detection System for Parkinson’s Disease
Su, F., Chen, M., Sun, Z., Xin, T., Su, F., & Chen, Y. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3314100 · Cited by 38
“Furthermore, due to its proximity to the center of gravity of the body, the waist serves as a typical location for capturing comprehensive movement patterns and is considered a standard sensor installation site [30], [31].”
BackgroundInfluentialChomiak, T., Xian, W., Pei, Z., & Hu, B. (2019) · Journal of Neural Transmission · doi:10.1007/s00702-019-02020-0 · Cited by 38
Rodríguez‐Molinero, A., Pérez‐López, C., Samà, A., Rodríguez-Martín, D., Alcaine, S., Mestre, B., Quispe, P., Giuliani, B., Vainstein, G., Browne, P. J., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-49798-3 · Cited by 41
Self-citationAshfaque Mostafa, T., Soltaninejad, S., McIsaac, T. L., & Cheng, I. (2021) · Sensors · doi:10.3390/s21196446 · Cited by 32
Detection and prediction of freezing of gait with wearable sensors in Parkinson’s disease
Zhang, W., Sun, H., Huang, D., Zhang, Z., Li, J., Wu, C., Sun, Y., Gong, M., Wang, Z., Sun, C., et al. (2023) · Neurological Sciences · doi:10.1007/s10072-023-07017-y · Cited by 36
“Some studies [44, 45, 54, 71] had only one rater to annotate FoG episodes from videos, which might be prone to cause a partiality of labeling because of raters’ subjectivity and inexperience.”
Caballol, N. S., Bayés, À., Prats, A., Martín‐Baranera, M., & Quispe, P. (2023) · PLoS ONE · doi:10.1371/journal.pone.0279910 · Cited by 34
“With respect to the FoG, in the previous algorithm validation study of this WIS, the sensitivity and specificity were around 85% [43].”
MethodSelf-citationDetection of Freezing of Gait Using Unsupervised Convolutional Denoising Autoencoder
Noor, M. H. M., Nazir, A., Wahab, M. N. A., & Ling, J. O. Y. (2021) · IEEE Access · doi:10.1109/access.2021.3104975 · Cited by 33
“This leads to an explosion in the number of features; up to 55 feature sets were categorized into 12 groups [4].”
BackgroundMethodInfluentialPlant defensin antibacterial mode of action against Pseudomonas species
Sathoff, A. E., Lewenza, S., & Samac, D. A. (2020) · BMC Microbiology · doi:10.1186/s12866-020-01852-1 · Cited by 32
Using Biometric Technology for Telehealth and Telerehabilitation
Annaswamy, T. M., Pradhan, G. N., Chakka, K., Khargonkar, N., Borresen, A., & Prabhakaran, B. (2021) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2020.12.007 · Cited by 30
The TRACK-PD study: protocol of a longitudinal ultra-high field imaging study in Parkinson’s disease
Wolters, A. F., Heijmans, M., Michielse, S., Leentjens, A. F. G., Postma, A. A., Jansen, J. F. A., Ivanov, D., Duits, A., Temel, Y., & Kuijf, M. L. (2020) · BMC Neurology · doi:10.1186/s12883-020-01874-2 · Cited by 29
Masiala, S., Huijbers, W., & Atzmueller, M. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1909.03428 · Cited by 30
“ly FoG episodes happening for specific walking tasks such as full rapid turns and walking with short steps. Finally, they reported a Sensitivity of 75% and Specificity of 76%. Recently, Rodriguez et al.[36] proposed a new machine learning approach for FoG detection based on a set of 55 features using a Support Vector Ma…”
MethodKwon, H., Clifford, G. D., Genias, I., Bernhard, D., Esper, C. D., Factor, S. A., & McKay, J. L. (2023) · Sensors · doi:10.3390/s23041766 · Cited by 24
IoT-based freezing of gait detection using grey relational analysis
Ghosh, N., & Banerjee, I. (2019) · Internet of Things · doi:10.1016/j.iot.2019.100068 · Cited by 26
Borzì, L., Sigcha, L., & Olmo, G. (2023) · Sensors · doi:10.3390/s23094426 · Cited by 29
“For this reason, some research studies included a set of unscripted activities, such as random walking [32] and simulated activities of daily living (ADLs) [41].”
BackgroundInfluentialObjective measurement versus clinician-based assessment for Parkinson’s disease
Guerra, A., D’Onofrio, V., Ferreri, F., Bologna, M., & Antonini, A. (2023) · Expert Review of Neurotherapeutics · doi:10.1080/14737175.2023.2229954 · Cited by 30
“Home-based monitoring of FOG using IMUs was also performed using a single waist-worn sensor [121,122] or several sensors [123](Ahmadi et al.”
MethodZampogna, A., Borzì, L., Rinaldi, D., Artusi, C. A., Imbalzano, G., Patera, M., Lopiano, L., Pontieri, F. E., Olmo, G., & Suppa, A. (2024) · Bioengineering · doi:10.3390/bioengineering11050440 · Cited by 29
“Additionally, it opens up the prospect of implementing telemedicine procedures in patients affected by movement disorders.”
BackgroundFreezing of Gait Detection for Parkinson’s Disease Patients using Accelerometer Data: Case Study
Tăuţan, A.-M., Andrei, A.-G., & Ionescu, B. E. (2020) · E-Health and Bioengineering Conference (EHB) · doi:10.1109/ehb50910.2020.9280223 · Cited by 26
“Rodríguez-Martín et al. [5] proposed a system for FoG detection during developed on data recorded during normal activities of daily living.”
BackgroundBorzì, L., Fornara, S., Amato, F., Olmo, G., Artusi, C. A., & Lopiano, L. (2020) · Electronics · doi:10.3390/electronics9060919 · Cited by 24
Wang, C., Peng, L., Hou, Z., Li, Y., Tan, Y., & Hao, H. (2021) · IEEE Transactions on Cognitive and Developmental Systems · doi:10.1109/tcds.2021.3123157 · Cited by 26
Wu, X., Ma, L., Wei, P., Shan, Y., Chan, P., Wang, K., & Zhao, G. (2024) · Frontiers in Neurology · doi:10.3389/fneur.2024.1387477 · Cited by 31
Polymorphisms in TLRs influence circulating cytokines production in Plasmodium vivax malaria
Costa, A. G., Ramasawmy, R., Val, F., Ibiapina, H. N. S., de Oliveira, A. C., Tarragô, A. M., Garcia, N. P., Heckmann, M. I. O., Monteiro, W. M., Malheiro, A., et al. (2018) · Cytokine · doi:10.1016/j.cyto.2018.04.008 · Cited by 25
Self-citationYan, Y., Liu, Y.-S., Li, C., Wang, J., Ma, L., Xiong, J., Zhao, X., & Wang, L. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3142750 · Cited by 27
Pérez‐López, C., Hernández‐Vara, J., Caballol, N. S., Bayés, À., Buongiorno, M., López-Ariztegui, N., Gironell, A., López‐Sánchez, J. D., Martínez‐Castrillo, J. C., Álvarez, S. M., et al. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2022.835249 · Cited by 22
“The Holter records motor fluctuations during activities of daily living (11), in addition to dyskinesia, bradykinesia, and freezing-of-gait episodes (11, 12, 16, 20).”
BackgroundSelf-citationRecognition of Freezing of Gait in Parkinson’s Disease Based on Machine Vision
Li, W., Chen, X., Zhang, J., Lu, J., Zhang, C., Bai, H., Liang, J., Wang, J., Du, H., Xue, G., et al. (2022) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2022.921081 · Cited by 25
Elbatanouny, H., Kleanthous, N., Dahrouj, H., Alusi, S. H., Almajali, E. R., Mahmoud, S. A., & Hussain, A. J. (2024) · Sensors · doi:10.3390/s24123959 · Cited by 24
“Their frequent use ([34,42,46,56,57,61,62,66,69,74,83,87,90,91,93,97,99,102–104,108,110,113,117, Reflecting the total magnitude and distribution of energy across signal frequencies, signal energy [44,57,61,66–69,74,83,93, 103 , 106,108, Kurtosis [46,56,61,74,83,90,91,95,99,104,110,117], Skewness…”
BackgroundInfluentialKusins, J. R., Knowles, N. K., Columbus, M. P., Oliviero, S., Dall’Ara, E., Athwal, G. S., & Ferreira, L. M. (2020) · Annals of Biomedical Engineering · doi:10.1007/s10439-020-02549-2 · Cited by 20
Alibrahim, A., AlRamadhan, D., Johny, S., Alhashemi, M., Alduwaisan, H., & Al‐Hilal, M. (2020) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2020.108567 · Cited by 26
Exploring Perceptions of Cross-Sectoral Data Sharing with People with Parkinson’s
McNaney, R., Morgan, C., Kulkarni, P., Vega, J., Heidarivincheh, F., McConville, R., Whone, A. L., Kim, M., Kirkham, R., & Craddock, I. J. (2022) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3491102.3501984 · Cited by 26
“This includes wearable sensors [21, 38, 39, 82, 84], which contain accelerometers and gyroscopes to observe and quantify motor func-”
BackgroundCommercial symptom monitoring devices in Parkinson’s disease: benefits, limitations, and trends
Rodríguez-Martín, D., & Pérez‐López, C. (2024) · Frontiers in Neurology · doi:10.3389/fneur.2024.1470928 · Cited by 22
Self-citationVirbel-Fleischman, C., Rétory, Y., Hardy, S., Huiban, C., Corvol, J., & Grabli, D. (2022) · PLoS ONE · doi:10.1371/journal.pone.0265438 · Cited by 21
A bag-of-words feature engineering approach for assessing health conditions using accelerometer data
Rastegari, E., & Ali, H. (2020) · Smart Health · doi:10.1016/j.smhl.2020.100116 · Cited by 19
Detection of Freezing of Gait in People with Parkinson’s Disease using Smartphones
Borzì, L., Olmo, G., Artusi, C. A., & Lopiano, L. (2020) · IEEE Annual International Computer Software and Applications Conference (COMPSAC) · doi:10.1109/compsac48688.2020.0-186 · Cited by 22
Impacts of an Amazonian hydroelectric dam on frog assemblages
Dayrell, J. S., Magnusson, W. E., Bobrowiec, P. E. D., & LIMA, A. P. (2021) · PLoS ONE · doi:10.1371/journal.pone.0244580 · Cited by 24
Youn, I.-H., Leutzinger, T. J., Youn, J.-H., Zeni, J., & Knarr, B. A. (2020) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2020.569932 · Cited by 21
Metadata
- Authors
- Rodríguez-Martín, D., Samà, A., Pérez-López, C., Català, A., Moreno Arostegui, J. M., Cabestany, J., Bayés, À., Alcaine, S., Mestre, B., Prats, A., Crespo, M. C., Counihan, T. J., Browne, P., Quinlan, L. R., ÓLaighin, G., Sweeney, D., Lewy, H., Azuri, J., Vainstein, G., Annicchiarico, R., Costa, A., & Rodríguez-Molinero, A.
- Affiliations
- Universitat Politècnica de Catalunya (ES)
- Ollscoil na Gaillimhe – University of Galway (IE)
- Maccabi Healthcare Services (IL)
- Tel Aviv University (IL)
- Fondazione Santa Lucia (IT)
- Corresponding author
- Rodríguez-Martín, Daniel
- Samà, Albert
- Cabestany, Joan
- Bayés, Àngels
- Alcaine, Sheila
- Mestre, Berta
- Prats, Anna
- Crespo, M. Cruz
- Counihan, Timothy J.
- Browne, Patrick
- Quinlan, Leo R.
- Sweeney, Dean
- Lewy, Hadas
- Azuri, Joseph
- Vainstein, Gabriel
- Annicchiarico, Roberta
- Costa, Alberto
- ORCID
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-02-15
- Volume
- 12
- Issue
- 2
- Pages
- e0171764
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC5310916
- OpenAlex
- W2588989789
- Cited by
- 237
- References
- 72
- Citations by year
- 2026: 9 · 2025: 21 · 2024: 22 · 2023: 31 · 2022: 34 · 2021: 34 · 2020: 29 · 2019: 27 · 2018: 21 · 2017: 9
- FWCI
- 58.16
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Arrow@dit (Dublin Institute of Technology) (acceptedVersion)
- ARAN (University of Galway Research Repository) (Ollscoil na Gaillimhe – University of Galway) (acceptedVersion, cc-by-nc-nd)
- RECERCAT (Consorci de Serveis Universitaris de Catalunya) (acceptedVersion, other-oa)
- UPCommons institutional repository (Universitat Politècnica de Catalunya) (submittedVersion, cc-by-nc-nd)
- ARAN (University of Galway Research Repository) (Ollscoil na Gaillimhe – University of Galway) (submittedVersion, cc-by-nc-nd)
- Arrow@dit (Dublin Institute of Technology) (submittedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- University of Galway Research Repository (submittedVersion, cc-by)
- Funders
- European Commission (287677)
- Topics
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Keywords
- freezing of gait, Parkinson's disease, triaxial accelerometer, support vector machine, home monitoring, wearable sensors, gait analysis, activities of daily living, symptom severity assessment
- MeSH terms
- Activities of Daily Living, Aged, Aged, 80 and over, Female, Humans, Male, Middle Aged, Parkinson Disease, Walking, Support Vector Machine, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.