Benzene formation in electronic cigarettes
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
BACKGROUND/OBJECTIVE: The heating of the fluids used in electronic cigarettes ("e-cigarettes") used to create "vaping" aerosols is capable of causing a wide range of degradation reaction products. We investigated formation of benzene (an important human carcinogen) from e-cigarette fluids containing propylene glycol (PG), glycerol (GL), benzoic acid, the flavor chemical benzaldehyde, and nicotine. METHODS/MAIN RESULTS: Three e-cigarette devices were used: the JUULTM "pod" system (provides no user accessible settings other than flavor cartridge choice), and two refill tank systems that allowed a range of user accessible power settings. Benzene in the e-cigarette aerosols was determined by gas chromatography/mass spectrometry. Benzene formation was ND (not detected) in the JUUL system. In the two tank systems benzene was found to form from propylene glycol (PG) and glycerol (GL), and from the additives benzoic acid and benzaldehyde, especially at high power settings. With 50:50 PG+GL, for tank device 1 at 6W and 13W, the formed benzene concentrations were 1.9 and 750 μg/m3. For tank device 2, at 6W and 25W, the formed concentrations were ND and 1.8 μg/m3. With benzoic acid and benzaldehyde at ~10 mg/mL, for tank device 1, values at 13W were as high as 5000 μg/m3. For tank device 2 at 25W, all values were ≤~100 μg/m3. These values may be compared with what can be expected in a conventional (tobacco) cigarette, namely 200,000 μg/m3. Thus, the risks from benzene will be lower from e-cigarettes than from conventional cigarettes. However, ambient benzene air concentrations in the U.S. have typically been 1 μg/m3, so that benzene has been named the largest single known cancer-risk air toxic in the U.S. For non-smokers, chronically repeated exposure to benzene from e-cigarettes at levels such as 100 or higher μg/m3 will not be of negligible risk.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NMR Chemical Shifts of Common Laboratory Solvents as Trace Impurities
Gottlieb, H. E., Kotlyar, V., & Nudelman, A. (1997) · The Journal of Organic Chemistry · doi:10.1021/jo971176v · Cited by 3,745
Kosmider, L., Sobczak, A., Fik, M., Knysak, J., Zaciera, M., Kurek, J., & Goniewicz, M. L. (2014) · Nicotine & Tobacco Research · doi:10.1093/ntr/ntu078 · Cited by 707 · cited 1×
“Significant amounts of formaldehyde are also possible.[3,4] Kim and Kim [7], using a PG+GL refill fluid (zero nicotine), an unnamed refillable tank device operated, and unspecified settings, reported finding benzene (a known human carcinogen [8,9]) in e-cigarette aerosols at 87.”
BackgroundHidden formaldehyde in e-cigarette aerosols
Jensen, R. P., Luo, W., Pankow, J. F., Strongin, R. M., & Peyton, D. H. (2015) · New England Journal of Medicine · doi:10.1056/nejmc1413069 · Cited by 605 · cited 2×
“[4], the aerosol was drawn into a 1 mL septum vial containing 600 μL of DMSO-d6.”
BackgroundMethodSelf-citationEmissions from Electronic Cigarettes: Key Parameters Affecting the Release of Harmful Chemicals
Sleiman, M., Logue, J. M., Montesinos, V. N., Russell, M. L., Litter, M. I., Gundel, L. A., & Destaillats, H. (2016) · Environmental Science & Technology · doi:10.1021/acs.est.6b01741 · Cited by 446
Flavour chemicals in electronic cigarette fluids
Tierney, P. A., Karpinski, C. D., Brown, J. E., Luo, W., & Pankow, J. F. (2016) · Tobacco Control · doi:10.1136/tobaccocontrol-2014-052175 · Cited by 365 · cited 1×
“[13]) For a third route to benzene, many aromatic aldehydes are major eliquid flavor additives, including benzaldehyde (for “cherry”), vanillin, and ethyl vanillin: aldehyde levels as high as several percent (by mass) have been found.[14] Every aldehyde can be oxidized to its corresponding carboxylic acid, which may t…”
BackgroundSelf-citationComparison of the effects of e-cigarette vapor and cigarette smoke on indoor air quality
McAuley, T. R., Hopke, P. K., Zhao, J., & Babaian, S. (2012) · Inhalation Toxicology · doi:10.3109/08958378.2012.724728 · Cited by 309 · cited 1×
“McAuley et al.[10], however, using a simple draw-activated device, reported that benzene was mostly “not found”.”
MethodSolvent Chemistry in the Electronic Cigarette Reaction Vessel
Jensen, R. P., Strongin, R. M., & Peyton, D. H. (2017) · Scientific Reports · doi:10.1038/srep42549 · Cited by 179 · cited 1×
“[2–6] Thermal dehydration of PG with loss of one water molecule gives acetaldehyde, and thermal dehydration of GL with loss of two water molecules gives acrolein [2, 6].”
BackgroundSelf-citationMining data on usage of electronic nicotine delivery systems (ENDS) from YouTube videos
Hua, M., Yip, H., & Talbot, P. (2013) · Tobacco Control · doi:10.1136/tobaccocontrol-2011-050226 · Cited by 165
Conversion of Glycerol to Alkyl-aromatics over Zeolites
Hoang, T. Q., Zhu, X., Danuthai, T., Lobban, L. L., Resasco, D. E., & Mallinson, R. G. (2010) · Energy & Fuels · doi:10.1021/ef100160y · Cited by 122 · cited 1×
“Dehydration of GL to benzene has been observed [11], and in e-cigarettes a simple dehydration stoichiometry could be PG + GL = benzene + 5 H2O (Fig 1A).”
BackgroundCalculated Cancer Risks for Conventional and “Potentially Reduced Exposure Product” Cigarettes
Pankow, J. F., Watanabe, K. H., Toccalino, P. L., Luo, W., & Austin, D. F. (2007) · Cancer Epidemiology Biomarkers & Prevention · doi:10.1158/1055-9965.epi-06-0762 · Cited by 60 · cited 1×
“Assuming a total puff volume of ~400 mL/cigarette for the smoking protocol used [22], such deliveries correspond to a smoke benzene concentration of ~200,000 μg/m(3), and so a much higher risk from benzene for chronic use of tobacco cigarettes as compared to e-cigarettes.”
BackgroundSelf-citation
Cited by
IQOS: examination of Philip Morris International’s claim of reduced exposure
St.Helen, G., Jacob III, P., Nardone, N., & Benowitz, N. L. (2018) · Tobacco Control · doi:10.1136/tobaccocontrol-2018-054321 · Cited by 207
Cao, D. J., Aldy, K., Hsu, S., McGetrick, M., Verbeck, G., De Silva, I., & Feng, S.-Y. (2020) · Journal of Medical Toxicology · doi:10.1007/s13181-020-00772-w · Cited by 201
“Furthermore, PG/VG-containing e-liquids, when heated, generate pulmonary irritants as well as known and suspected carcinogenic carbonyl compounds (formaldehyde, acetaldehyde, and acrolein) [13, 14].”
BackgroundCharacteristics and toxicant emissions of JUUL electronic cigarettes
Talih, S., Salman, R., El-Hage, R., Karam, E., Karaoghlanian, N., El-Hellani, A., Saliba, N., & Shihadeh, A. (2019) · Tobacco Control · doi:10.1136/tobaccocontrol-2018-054616 · Cited by 174
Metadata
- Authors
- Pankow, J. F., Kim, K., McWhirter, K. J., Luo, W., Escobedo, J. O., Strongin, R. M., Duell, A. K., & Peyton, D. H.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-03-08
- Volume
- 12
- Issue
- 3
- Pages
- e0173055
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2594514058
- Cited by
- 186
- References
- 12
- FWCI
- 15.79
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.