The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
A scoping review on bio-aerosols in healthcare and the dental environment
Open accessAbstract
BACKGROUND: Bio-aerosols originate from different sources and their potentially pathogenic nature may form a hazard to healthcare workers and patients. So far no extensive review on existing evidence regarding bio-aerosols is available. OBJECTIVES: This study aimed to review evidence on bio-aerosols in healthcare and the dental setting. The objectives were 1) What are the sources that generate bio-aerosols?; 2) What is the microbial load and composition of bio-aerosols and how were they measured?; and 3) What is the hazard posed by pathogenic micro-organisms transported via the aerosol route of transmission? METHODS: Systematic scoping review design. Searched in PubMed and EMBASE from inception to 09-03-2016. References were screened and selected based on abstract and full text according to eligibility criteria. Full text articles were assessed for inclusion and summarized. The results are presented in three separate objectives and summarized for an overview of evidence. RESULTS: The search yielded 5,823 studies, of which 62 were included. Dental hand pieces were found to generate aerosols in the dental settings. Another 30 sources from human activities, interventions and daily cleaning performances in the hospital also generate aerosols. Fifty-five bacterial species, 45 fungi genera and ten viruses were identified in a hospital setting and 16 bacterial and 23 fungal species in the dental environment. Patients with certain risk factors had a higher chance to acquire Legionella in hospitals. Such infections can lead to irreversible septic shock and death. Only a few studies found that bio-aerosol generating procedures resulted in transmission of infectious diseases or allergic reactions. CONCLUSION: Bio-aerosols are generated via multiple sources such as different interventions, instruments and human activity. Bio-aerosols compositions reported are heterogeneous in their microbiological composition dependent on the setting and methodology. Legionella species were found to be a bio-aerosol dependent hazard to elderly and patients with respiratory complaints. But all aerosols can be can be hazardous to both patients and healthcare workers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
RETRACTED: Dental unit waterlines: source of contamination and cross-infection
Kumar, S., Atray, D., Paiwal, D., et al. (2010) · Journal of Hospital Infection · doi:10.1016/j.jhin.2009.03.027 · Cited by 47
RetractedPreferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & the PRISMA Group* (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-4-200908180-00135 · Cited by 37,554
Wang, G., Ma, R., Qiao, G., Wada, K., Aizawa, Y., & Satoh, T. (2015) · Integrative Medicine International · doi:10.1159/000368408 · Cited by 18,657
Guidance for conducting systematic scoping reviews
Peters, M. D. J., Godfrey, C. M., Khalil, H., McInerney, P., Parker, D., & Soares, C. B. (2015) · International Journal of Evidence-Based Healthcare · doi:10.1097/xeb.0000000000000050 · Cited by 7,472
Tran, K., Cimon, K., Severn, M., Pessoa-Silva, C. L., & Conly, J. (2012) · PLoS ONE · doi:10.1371/journal.pone.0035797 · Cited by 1,811
The Joanna Briggs Institute reviewers' manual 2015: methodology for JBI scoping reviews
Peters, M. D. J., Godfrey, C. M., McInerney, P. A., Soares, C. B., Khalil, H., & Parker, D. (2015) · Cited by 1,135
Transmission of influenza A in human beings
Brankston, G., Gitterman, L., Hirji, Z., Lemieux, C., & Gardam, M. (2007) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(07)70029-4 · Cited by 744
The role of particle size in aerosolised pathogen transmission: a review
Gralton, J., Tovey, E., McLaws, M.-L., & Rawlinson, W. D. (2011) · Journal of Infection · doi:10.1016/j.jinf.2010.11.010 · Cited by 665
Aerosol transmission of influenza A virus: a review of new studies
Tellier, R. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0302.focus · Cited by 589
Methodology for jbi scoping reviews
Peters, M. D. J., Godfrey, C. M., McInerney, P. A., Soares, C. B., Khalil, H., & Parker, D. (2015) · Cited by 365
Cost-Effectiveness of Interventions to Promote Physical Activity: A Modelling Study
Cobiac, L. J., Vos, T., & Barendregt, J. J. (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000110 · Cited by 310
Napoli, C., Marcotrigiano, V., & Montagna, M. T. (2012) · BMC Public Health · doi:10.1186/1471-2458-12-594 · Cited by 244 · cited 2×
“Furthermore, in many studies variables in the experimental setup were not described, like sampling time, distance and sampling location.”
Barker, J., & Jones, M. V. (2005) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2005.02610.x · Cited by 219
Bacterial aerosols in dental practice – a potential hospital infection problem?
Rautemaa, R., Nordberg, A., Wuolijoki-Saaristo, K., & Meurman, J. H. (2006) · Journal of Hospital Infection · doi:10.1016/j.jhin.2006.04.011 · Cited by 211
Microbial aerosols in general dental practice
Bennett, A. M., Fulford, M. R., Walker, J. T., Bradshaw, D. J., Martin, M. V., & Marsh, P. D. (2000) · British Dental Journal · doi:10.1038/sj.bdj.4800859 · Cited by 208
Pneumonia associated with a dental unit waterline
Ricci, M. L., Fontana, S., Pinci, F., Fiumana, E., Pedna, M. F., Farolfi, P., Sabattini, M. A. B., & Scaturro, M. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60074-9 · Cited by 205
Microbiological assessment of indoor air quality at different hospital sites
Cabo Verde, S., Almeida, S. M., Matos, J., Guerreiro, D., Meneses, M., Faria, T., Botelho, D., Santos, M., & Viegas, C. (2015) · Research in Microbiology · doi:10.1016/j.resmic.2015.03.004 · Cited by 197
Dental bioaerosol as an occupational hazard in a dentist's workplace.
Szymańska, J. (2007) · PubMed · Cited by 181
Variability of Infectious Aerosols Produced during Coughing by Patients with Pulmonary Tuberculosis
Fennelly, K. P., Jones-López, E. C., Ayakaka, I., Kim, S., Menyha, H., Kirenga, B., Muchwa, C., Joloba, M., Dryden-Peterson, S., Reilly, N., et al. (2012) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201203-0444oc · Cited by 172
Exhalation of respiratory viruses by breathing, coughing, and talking
Stelzer‐Braid, S., Oliver, B. G., Blazey, A. J., Argent, E., Newsome, T. P., Rawlinson, W. D., & Tovey, E. R. (2009) · Journal of Medical Virology · doi:10.1002/jmv.21556 · Cited by 165 · cited 1×
“Two studies identified multiple viruses in bio-aerosols after patients with symptoms of a cold coughed, however both studies did not report on the viral load [51, 62].”
Quantitative analysis of bacterial aerosols in two different dental clinic environments
Grenier, D. (1995) · Applied and Environmental Microbiology · doi:10.1128/aem.61.8.3165-3168.1995 · Cited by 155
Viable Influenza A Virus in Airborne Particles from Human Coughs
Lindsley, W. G., Noti, J. D., Blachère, F. M., Thewlis, R. E., Martin, S. B., Othumpangat, S., Noorbakhsh, B., Goldsmith, W. T., Vishnu, A., Palmer, J. E., et al. (2014) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2014.973113 · Cited by 144
Variability of airborne microflora in a hospital ward within a period of one year.
Augustowska, M., & Dutkiewicz, J. K. (2006) · PubMed · Cited by 140
Wainwright, C. E., France, M. W., O'Rourke, P., Anuj, S., Kidd, T. J., Nissen, M. D., Sloots, T. P., Coulter, C., Ristovski, Z., Hargreaves, M., et al. (2009) · Thorax · doi:10.1136/thx.2008.112466 · Cited by 135
Best, E. L., Sandoe, J. A. T., & Wilcox, M. H. (2011) · Journal of Hospital Infection · doi:10.1016/j.jhin.2011.08.010 · Cited by 131
Serological Examinations for Antibodies against Legionella Species in Dental Personnel
Reinthaler, F. F., Mascher, F., & Stünzner, D. (1988) · Journal of Dental Research · doi:10.1177/00220345880670061001 · Cited by 127
Healthcare-associated viral and bacterial infections in dentistry
Laheij, A. M. G. A., Kistler, J. O., Belibasakis, G. N., Välimaa, H., de Soet, J. J., & 2011, E. O. M. W. (. (2012) · Journal of Oral Microbiology · doi:10.3402/jom.v4i0.17659 · Cited by 116
Self-citationViral contamination of aerosol and surfaces through toilet use in health care and other settings
Verani, M., Bigazzi, R., & Carducci, A. (2014) · American Journal of Infection Control · doi:10.1016/j.ajic.2014.03.026 · Cited by 114
Thompson, K., Pappachan, J., Bennett, A., Mittal, H., Macken, S., Dove, B. K., Nguyen‐Van‐Tam, J. S., Copley, V. R., O’Brien, S. J., Hoffman, P. N., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056278 · Cited by 113
Do contaminated dental unit waterlines pose a risk of infection?
Pankhurst, C. L., & Coulter, W. A. (2007) · Journal of Dentistry · doi:10.1016/j.jdent.2007.06.002 · Cited by 110
Anderson, K., Morris, G., Kennedy, H., Croall, J., Michie, J. R., Richardson, M. D., & Gibson, B. E. S. (1996) · Thorax · doi:10.1136/thx.51.3.256 · Cited by 107
Atmospheric contamination during ultrasonic scaling
Timmerman, M. F., Menso, L., Steinfort, J., et al. (2004) · Journal Of Clinical Periodontology · doi:10.1111/j.1600-051x.2004.00511.x · Cited by 102
Monitoramento de fungos anemófilos e de leveduras em unidade hospitalar
Martins-Diniz, J. N., da Silva, R. A. M., Miranda, E. T., & Mendes‐Giannini, M. J. S. (2005) · Revista de Saúde Pública · doi:10.1590/s0034-89102005000300010 · Cited by 99
A New Method for Sampling and Detection of Exhaled Respiratory Virus Aerosols
Huynh, K. N., Oliver, B. G. G., Stelzer‐Braid, S., Rawlinson, W. D., & Tovey, E. R. (2007) · Clinical Infectious Diseases · doi:10.1086/523000 · Cited by 91
Dutil, S., Veillette, M., Mériaux, A., Lazure, L., Barbeau, J., & Duchaine, C. (2007) · Environmental Microbiology · doi:10.1111/j.1462-2920.2007.01395.x · Cited by 89
Viability ofPseudomonas aeruginosain cough aerosols generated by persons with cystic fibrosis
Knibbs, L. D., Johnson, G. R., Kidd, T. J., Cheney, J. L., Grimwood, K., Kattenbelt, J. A., O'Rourke, P. K., Ramsay, K. A., Sly, P. D., Wainwright, C. E., et al. (2014) · Thorax · doi:10.1136/thoraxjnl-2014-205213 · Cited by 87
Characterization of indoor bioaerosols from a hospital ward in a tropical setting
Sudharsanam, S., Swaminathan, S., Ramalingam, A., Thangavel, G., Annamalai, R., Steinberg, R., Balakrishnan, K., & Srikanth, P. (2012) · African Health Sciences · doi:10.4314/ahs.v12i2.22 · Cited by 86
Measurement of Airborne Bacteria and Endotoxin Generated During Dental Cleaning
Dutil, S., Mériaux, A., de Latrémoille, M.-C., Lazure, L., Barbeau, J., & Duchaine, C. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620802633957 · Cited by 84
Qualitative and Quantitative Analysis of Bacterial Aerosols
Maghlouth, A. A., Yousef, Y. A., & Bagieh, N. A. (2004) · The Journal of Contemporary Dental Practice · doi:10.5005/jcdp-5-4-91 · Cited by 77
Isolation of pathogenic Legionella species and legionella-laden amoebae in dental unit waterlines
Singh, T., & Coogan, M. M. (2005) · Journal of Hospital Infection · doi:10.1016/j.jhin.2005.05.001 · Cited by 70
Pasquarella, C. I. M., Veronesi, L., Napoli, C., Castiglia, P., Liguori, G., Rizzetto, R., Torre, I., Righi, E., Farruggia, P., Tesauro, M., et al. (2012) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2012.01.030 · Cited by 68
Quantifying the risk of respiratory infection in healthcare workers performing high-risk procedures
MacIntyre, C. R., Seale, H., Yang, P., Zhang, Y., Shi, W., Almatroudi, A., Moa, A., Wang, X., LI, X., PANG, X., et al. (2013) · Epidemiology and Infection · doi:10.1017/s095026881300304x · Cited by 64
Fekadu, S., & Getachewu, B. (2015) · Ethiopian Journal of Health Sciences · doi:10.4314/ejhs.v25i2.3 · Cited by 60
Mirhoseini, S. H., Nikaeen, M., Khanahmd, H., Hatamzadeh, M., & Hassanzadeh, A. (2015) · Annals of Agricultural and Environmental Medicine · doi:10.5604/12321966.1185772 · Cited by 59
Bacterial aerosols in the dental clinic: effect of time, position and type of treatment
Kedjarune, U., Kukiattrakoon, B., Yapong, B., et al. (2000) · International Dental Journal · doi:10.1002/j.1875-595x.2000.tb00807.x · Cited by 56
A Study of Air Microbe Levels in Different Areas of a Hospital
Ortiz, G., Yagüe, G., Segovia, M., & Catalán, V. (2009) · Current Microbiology · doi:10.1007/s00284-009-9398-7 · Cited by 55
Detection of Measles Virus RNA in Air and Surface Specimens in a Hospital Setting
Bischoff, W. E., McNall, R. J., Blevins, M. W., Turner, J., Lopareva, E. N., Rota, P. A., & Stehle, J. (2015) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiv465 · Cited by 52
Pankhurst, C. L., Coulter, W. A., Philpott‐Howard, J., Harrison, T. G., Warburton, F. G., Platt, S., Surman, S., & Challacombe, S. (2003) · BDJ · doi:10.1038/sj.bdj.4810735 · Cited by 50
Prevalence of anti-legionella antibodies among Italian hospital workers
Borella, P., Bargellini, A., Marchesi, I., et al. (2008) · Journal of Hospital Infection · doi:10.1016/j.jhin.2008.03.004 · Cited by 50
Schaffer, K. (2015) · Journal of Hospital Infection · doi:10.1016/j.jhin.2015.02.005 · Cited by 49
Microbial contamination of dental unit waterlines and effect on quality of indoor air
Kadaifçiler, D. G., & Çotuk, A. (2014) · Environmental Monitoring and Assessment · doi:10.1007/s10661-014-3628-6 · Cited by 47
Chen, P., & Li, C.-S. (2005) · Aerosol Science and Technology · doi:10.1080/027868290945767 · Cited by 40
A Case Series: Herpes Simplex Virus as an Occupational Hazard
Browning, W. D., & McCarthy, J. P. (2011) · Journal of Esthetic and Restorative Dentistry · doi:10.1111/j.1708-8240.2011.00469.x · Cited by 39
Quantitative microbial monitoring in a dental office
Cellini, L., Campli, E. D., Candia, M. D., et al. (2001) · Public Health · doi:10.1038/sj.ph.1900746 · Cited by 23
Mirzaei, R., Shahriary, E., Iqbal-Qureshi, M., Rakhshkhorshid, A., Khammary, A., & Mohammadi, M. (2014) · Jundishapur Journal of Microbiology · doi:10.5812/jjm.11688 · Cited by 22
Szymańska, J., & Dutkiewicz, J. K. (2008) · PubMed · Cited by 22
Bioaerosol exposure to personnel in a clinical environment absent patients
Heimbuch, B. K., Wallace, W. H., Balzli, C. L., Laning, M. L., Harnish, D. A., & Wander, J. D. (2015) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2015.1091966 · Cited by 11
Exposure of Dentists toMycobacterium tuberculosis, Ibadan, Nigeria
Cadmus, S., Okoje, V. N., Taiwo, B., & van Soolingen, D. (2010) · Emerging infectious diseases · doi:10.3201/eid1609.100447 · Cited by 10
Droplet nuclei produced during dental treatment of tubercular patients
Duell, R. C., & Madden, R. M. (1970) · Oral Surgery Oral Medicine Oral Pathology · doi:10.1016/0030-4220(70)90398-1 · Cited by 9
Cited by
Possible aerosol transmission of COVID-19 and special precautions in dentistry
Ge, Z.-Y., Yang, L.-M., Xia, J.-J., Fu, X.-H., & Zhang, Y.-Z. (2020) · Journal of Zhejiang University-SCIENCE B · doi:10.1631/jzus.b2010010 · Cited by 702
Khader, Y., Al Nsour, M., Al-Batayneh, O. B., Saadeh, R., Bashier, H., Alfaqih, M., Al-Azzam, S., & AlShurman, B. A. (2020) · JMIR Public Health and Surveillance · doi:10.2196/18798 · Cited by 513
COVID-19 Transmission in Dental Practice: Brief Review of Preventive Measures in Italy
Izzetti, R., Nisi, M., Gabriele, M., & Graziani, F. (2020) · Journal of Dental Research · doi:10.1177/0022034520920580 · Cited by 484
Do exposures to aerosols pose a risk to dental professionals?
Kobza, J., Pastuszka, J. S., & Brągoszewska, E. (2018) · Occupational Medicine · doi:10.1093/occmed/kqy095 · Cited by 67
Al-Shaarani, A. A. Q. A., & Pecoraro, L. (2024) · Frontiers in Microbiology · doi:10.3389/fmicb.2024.1428415 · Cited by 50
Metadata
- Authors
- Zemouri, C., de Soet, H., Crielaard, W., & Laheij, A.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-05-22
- Volume
- 12
- Issue
- 5
- Pages
- e0178007
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2617183272
- Cited by
- 335
- References
- 61
- FWCI
- 16.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.