CoChat

Computer-aided detection of brain metastasis on 3D MR imaging: Observer performance study

Open access

The DOI matches its Crossref record; 50 of the 51 references it cites were found in a registry or an index, and 1 are not checked yet.

Abstract

PURPOSE: To assess the effect of computer-aided detection (CAD) of brain metastasis (BM) on radiologists' diagnostic performance in interpreting three-dimensional brain magnetic resonance (MR) imaging using follow-up imaging and consensus as the reference standard. MATERIALS AND METHODS: The institutional review board approved this retrospective study. The study cohort consisted of 110 consecutive patients with BM and 30 patients without BM. The training data set included MR images of 80 patients with 450 BM nodules. The test set included MR images of 30 patients with 134 BM nodules and 30 patients without BM. We developed a CAD system for BM detection using template-matching and K-means clustering algorithms for candidate detection and an artificial neural network for false-positive reduction. Four reviewers (two neuroradiologists and two radiology residents) interpreted the test set images before and after the use of CAD in a sequential manner. The sensitivity, false positive (FP) per case, and reading time were analyzed. A jackknife free-response receiver operating characteristic (JAFROC) method was used to determine the improvement in the diagnostic accuracy. RESULTS: The sensitivity of CAD was 87.3% with an FP per case of 302.4. CAD significantly improved the diagnostic performance of the four reviewers with a figure-of-merit (FOM) of 0.874 (without CAD) vs. 0.898 (with CAD) according to JAFROC analysis (p < 0.01). Statistically significant improvement was noted only for less-experienced reviewers (FOM without vs. with CAD, 0.834 vs. 0.877, p < 0.01). The additional time required to review the CAD results was approximately 72 sec (40% of the total review time). CONCLUSION: CAD as a second reader helps radiologists improve their diagnostic performance in the detection of BM on MR imaging, particularly for less-experienced reviewers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0178265

Cites

50 of 51 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig 1 Flow diagram for patient selection. The diagram shows the initial case selection and final distribution of study cases into the training set and test set. Jan = January, Mar = March.
Fig 1 Flow diagram for patient selection. The diagram shows the initial case selection and final distribution of study cases into the training set and test set. Jan = January, Mar = March.CC BY · PubMed Central
Fig 2 Flow diagram of our proposed CAD algorithms. TP = true positive, FP = false positive, ANN = artificial neural network.
Fig 2 Flow diagram of our proposed CAD algorithms. TP = true positive, FP = false positive, ANN = artificial neural network.CC BY · PubMed Central
Fig 3 Six spherical templates by sizes (2, 3, and 4 mm) and types (solid and inner-hole).
Fig 3 Six spherical templates by sizes (2, 3, and 4 mm) and types (solid and inner-hole).CC BY · PubMed Central
Fig 4 Example of an ANN for FP reduction of BM candidates using computer features.
Fig 4 Example of an ANN for FP reduction of BM candidates using computer features.CC BY · PubMed Central
Fig 5 Bar graph of the nodule size distributions in the training and test sets. The relative frequency of nodules with diameters of 1 to 3 mm differed significantly between the two groups (p = 0.01).
Fig 5 Bar graph of the nodule size distributions in the training and test sets. The relative frequency of nodules with diameters of 1 to 3 mm differed significantly between the two groups (p = 0.01).CC BY · PubMed Central
Fig 6 Examples of CAD results using algorithm A. A–D: Examples of the correct detection of BM by CAD software. E–H: Examples of the incorrect detection (FPs) by CAD software. Common sources of FPs included the cortical vessel (F), dural sinus (G), and choroid plexus (H).
Fig 6 Examples of CAD results using algorithm A. A–D: Examples of the correct detection of BM by CAD software. E–H: Examples of the incorrect detection (FPs) by CAD software. Common sources of FPs included the cortical vessel (F), dural sinus (G), and choroid plexus (H).CC BY · PubMed Central
Fig 7 3D gradient-echo contrast-enhanced T1-weighted MR images in an 81-year-old female patient with metastatic lung cancer. A and B: Axial (A) and coronal (B) images show a tiny enhancing nodule at the left inferior temporal gyrus (arrowhead). This nodule was missed by all four reviewers but was successfully detected by CAD. C: On the navigation MR image for a gamma-knife surgery performed 2 days after (A) and (B), the nodule showed no interval changes. D: On the follow-up MR image taken after 3 months, the nodule disappeared.
Fig 7 3D gradient-echo contrast-enhanced T1-weighted MR images in an 81-year-old female patient with metastatic lung cancer. A and B: Axial (A) and coronal (B) images show a tiny enhancing nodule at the left inferior temporal gyrus (arrowhead). This nodule was missed by all four reviewers but was successfully detected by CAD. C: On the navigation MR image for a gamma-knife surgery performed 2 days after (A) and (B), the nodule showed no interval changes. D: On the follow-up MR image taken after 3 months, the nodule disappeared.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 51 references

Cited by

See all 52

Metadata

Authors
Sunwoo, L., Kim, Y. J., Choi, S. H., Kim, K.-G., Kang, J. H., Kang, Y., Bae, Y. J., Yoo, R.-E., Kim, J., Lee, K. J., Lee, S. H., Choi, B. S., Jung, C., Sohn, C.-H., & Kim, J. H.
Affiliations
  • Seoul National University (KR)
  • Gachon University (KR)
  • Kwangwoon University (KR)
Corresponding author
  • Choi, Seung Hong
  • Kim, Kwang-Gi
Venue
PLOS ONE
Published
2017-06-08
Volume
12
Issue
6
Pages
e0178265
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2621805112
Cited by
52
References
50
Citations by year
2026: 2 · 2025: 2 · 2024: 13 · 2023: 3 · 2022: 10 · 2021: 10 · 2020: 5 · 2019: 3 · 2018: 4
FWCI
1.96
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Figshare (submittedVersion, cc-by)
Funders
  • SNUH Research Fund (0320140350 (2014-1078))
  • National Research Foundation of Korea (NRF-2015R1C1A1A02037475)
Topics
  • Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Brain Tumor Detection and Classification
  • Health Sciences › Medicine › Oncology › Brain Metastases and Treatment
Keywords
brain metastases, computer-aided detection, 3D MRI, observer performance, template matching, K-means clustering, artificial neural networks, false positive reduction, second reader, diagnostic accuracy, reading time, neuroradiologists, radiology residents
MeSH terms
Machine Learning, Aged, Algorithms, Brain Neoplasms, Female, Humans, Magnetic Resonance Imaging, Male, Middle Aged, Models, Theoretical, Retrospective Studies, Sensitivity and Specificity, Software, Tomography, X-Ray Computed, Imaging, Three-Dimensional

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.