Harmonizing the pixel size in retrospective computed tomography radiomics studies
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Consistent pixel sizes are of fundamental importance for assessing texture features that relate intensity and spatial information in radiomics studies. To correct for the effects of variable pixel sizes, we combined image resampling with Butterworth filtering in the frequency domain and tested the correction on computed tomography (CT) scans of lung cancer patients reconstructed 5 times with pixel sizes varying from 0.59 to 0.98 mm. One hundred fifty radiomics features were calculated for each preprocessing and field-of-view combination. Intra-patient agreement and inter-patient agreement were compared using the overall concordance correlation coefficient (OCCC). To further evaluate the corrections, hierarchical clustering was used to identify patient scans before and after correction. To assess the general applicability of the corrections, they were applied to 17 CT scans of a radiomics phantom. The reduction in the inter-scanner variability relative to non-small cell lung cancer patient scans was quantified. The variation in pixel sizes caused the intra-patient variability to be large (OCCC <95%) relative to the inter-patient variability in 79% of the features. However, with the resampling and filtering corrections, the intra-patient variability was relatively large in only 10% of the features. With the filtering correction, 8 of 8 patients were correctly clustered, in contrast to only 2 of 8 without the correction. In the phantom study, resampling and filtering the images of a rubber particle cartridge substantially reduced variability in 61% of the radiomics features and substantially increased variability in only 6% of the features. Surprisingly, resampling without filtering tended to increase the variability. In conclusion, applying a correction based on resampling and Butterworth low-pass filtering in the frequency domain effectively reduced variability in CT radiomics features caused by variations in pixel size. This correction may also reduce the variability introduced by other CT scan acquisition parameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
Radiomics: the process and the challenges
Kumar, V., Gu, Y., Basu, S., Berglund, A., Eschrich, S. A., Schabath, M. B., Forster, K., Aerts, H. J. W. L., Dekker, A., Fenstermacher, D., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.010 · Cited by 2,258
CT-based radiomic signature predicts distant metastasis in lung adenocarcinoma
Coroller, T. P., Grossmann, P., Hou, Y., Rios Velazquez, E., Leijenaar, R. T. H., Hermann, G., Lambin, P., Haibe-Kains, B., Mak, R. H., & Aerts, H. J. W. L. (2015) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2015.02.015 · Cited by 695
Overall Concordance Correlation Coefficient for Evaluating Agreement Among Multiple Observers
Barnhart, H. X., Haber, M., & Song, J. (2002) · Biometrics · doi:10.1111/j.0006-341x.2002.01020.x · Cited by 263
Cited by
Zwanenburg, A., Vallières, M., Abdalah, M. A., Aerts, H. J. W. L., Andrearczyk, V., Apte, A., Ashrafinia, S., Bakas, S., Beukinga, R. J., Boellaard, R., et al. (2020) · Radiology · doi:10.1148/radiol.2020191145 · Cited by 4,177
Radiomics in medical imaging—“how-to” guide and critical reflection
van Timmeren, J. E., Cester, D., Tanadini-Lang, S., Alkadhi, H., & Baessler, B. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00887-2 · Cited by 1,316
Liu, Z., Wang, S., Dong, D., Wei, J., Fang, C., Zhou, X., Sun, K., Li, L., Li, B., Wang, M., et al. (2019) · Theranostics · doi:10.7150/thno.30309 · Cited by 967
Berenguer, R., Pastor-Juan, M. D. R., Canales-Vázquez, J., Castro-García, M., Villas, M. V., Mansilla Legorburo, F., & Sabater, S. (2018) · Radiology · doi:10.1148/radiol.2018172361 · Cited by 622
Validation of A Method to Compensate Multicenter Effects Affecting CT Radiomics
Orlhac, F., Frouin, F., Nioche, C., Ayache, N., & Buvat, I. (2019) · Radiology · doi:10.1148/radiol.2019182023 · Cited by 411
A Guide to ComBat Harmonization of Imaging Biomarkers in Multicenter Studies
Orlhac, F., Eertink, J. J., Cottereau, A.-S., Zijlstra, J. M., Thieblemont, C., Meignan, M., Boellaard, R., & Buvat, I. (2022) · Journal of Nuclear Medicine · doi:10.2967/jnumed.121.262464 · Cited by 348
Zwanenburg, A. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04391-8 · Cited by 306
Understanding Sources of Variation to Improve the Reproducibility of Radiomics
Zhao, B. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.633176 · Cited by 158
The effect of preprocessing filters on predictive performance in radiomics
Demircioğlu, A. (2022) · European Radiology Experimental · doi:10.1186/s41747-022-00294-w · Cited by 75
“For example, in our study, all scans were homogeneously resampled since it was shown that this might increase predictive performance [29].”
Learning from scanners: Bias reduction and feature correction in radiomics
Zhovannik, I., Bussink, J., Traverso, A., Shi, Z., Kalendralis, P., Wee, L., Dekker, A., Fijten, R., & Monshouwer, R. (2019) · Clinical and Translational Radiation Oncology · doi:10.1016/j.ctro.2019.07.003 · Cited by 75
Polk, S. L., Choi, J. W., McGettigan, M. J., Rose, T., Ahmed, A., Kim, J., Jiang, K., Balagurunathan, Y., Qi, J., Farah, P. T., et al. (2020) · World Journal of Gastroenterology · doi:10.3748/wjg.v26.i24.3458 · Cited by 48
Metadata
- Authors
- Mackin, D., Fave, X., Zhang, L., Yang, J., Jones, A. K., Ng, C. S., & Court, L.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-09-21
- Volume
- 12
- Issue
- 9
- Pages
- e0178524
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2757342873
- Cited by
- 165
- References
- 4
- FWCI
- 12.69
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.