Falls are a major cause of injuries and deaths in older adults. Even when no injury occurs, about half of all older adults who fall are unable to get up without assistance. The extended period of lying on the floor often leads to medical complications, including muscle damage, dehydration, anxiety and fear of falling. Wearable sensor systems incorporating accelerometers and/or gyroscopes are designed to prevent long lies by automatically detecting and alerting care providers to the occurrence of a fall. Research groups have reported up to 100% accuracy in detecting falls in experimental settings. However, there is a lack of studies examining accuracy in the real-world setting. In this study, we examined the accuracy of a fall detection system based on real-world fall and non-fall data sets. Five young adults and 19 older adults went about their daily activities while wearing tri-axial accelerometers. Older adults experienced 10 unanticipated falls during the data collection. Approximately 400 hours of activities of daily living were recorded. We employed a machine learning algorithm, Support Vector Machine (SVM) classifier, to identify falls and non-fall events. We found that our system was able to detect 8 out of the 10 falls in older adults using signals from a single accelerometer (waist or sternum). Furthermore, our system did not report any false alarm during approximately 28.5 hours of recorded data from young adults. However, with older adults, the false positive rate among individuals ranged from 0 to 0.3 false alarms per hour. While our system showed higher fall detection and substantially lower false positive rate than the existing fall detection systems, there is a need for continuous efforts to collect real-world data within the target population to perform fall validation studies for fall detection systems on bigger real-world fall and non-fall datasets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Satisfaction and use of personal emergency response systems
Heinbüchner, B., Hautzinger, M., Becker, C., & Pfeiffer, K. (2010) · Zeitschrift für Gerontologie und Geriatrie · doi:10.1007/s00391-010-0127-4 · Cited by 70
Self-citation
Cited by
Application Scenarios for Artificial Intelligence in Nursing Care: Rapid Review
Seibert, K., Domhoff, D., Bruch, D., Schulte-Althoff, M., Fürstenau, D., Biessmann, F., & Wolf-Ostermann, K. (2021) · Journal of Medical Internet Research · doi:10.2196/26522 · Cited by 314
Villegas-Ch, W., Buenano-Fernandez, D., Navarro, A. M., & Mera-Navarrete, A. (2025) · Smart Learning Environments · doi:10.1186/s40561-025-00389-y · Cited by 80
“Normalization is one of the techniques used in the interaction and performance datasets of the 450 students evaluated in this system (Aziz et al., 2017).”
A review of sampling, energy supply and intelligent monitoring for long-term sweat sensors
Yang, P., Wei, G., Liu, A., Huo, F., & Zhang, Z. (2022) · npj Flexible Electronics · doi:10.1038/s41528-022-00165-9 · Cited by 77
Shishov, N., Elabd, K., Komisar, V., Chong, H., & Robinovitch, S. N. (2021) · PLOS ONE · doi:10.1371/journal.pone.0258923 · Cited by 42
Self-citation
Metadata
- Authors
- Aziz, O., Klenk, J., Schwickert, L., Chiari, L., Becker, C., Park, E. J., Mori, G., & Robinovitch, S. N.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-07-05
- Volume
- 12
- Issue
- 7
- Pages
- e0180318
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2733439154
- Cited by
- 92
- References
- 1
- FWCI
- 2.36
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of accuracy of SVM-based fall detection system using real-world fall and non-fall datasets. https://app.cochat.ai/papers/10.1371/journal.pone.0180318
- The paper
- Aziz, O., Klenk, J., Schwickert, L., Chiari, L., Becker, C., Park, E. J., Mori, G., & Robinovitch, S. N. (2017). Validation of accuracy of SVM-based fall detection system using real-world fall and non-fall datasets. PLOS ONE. https://doi.org/10.1371/journal.pone.0180318
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.