CoChat

Changes in aortic pulse wave velocity of four thoracic aortic stent grafts in an ex vivo porcine model

Open access
de Beaufort, Hector W. L., Coda, Margherita, Conti, Michele, van Bakel, Theodorus M. J., Nauta, Foeke J. H., Lanzarone, Ettore, Moll, Frans L., van Herwaarden, Joost A., Auricchio, Ferdinando, Trimarchi, Santi · 2017 · PLOS ONE
Cited by 62

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: Thoracic endovascular aortic repair (TEVAR) has been shown to lead to increased aortic stiffness. The aim of this study was to investigate the effect of stent graft type and stent graft length on aortic stiffness in a controlled, experimental setting. METHODS: Twenty porcine thoracic aortas were connected to a pulsatile mock loop system. Intraluminal pressure was recorded at two sites in order to measure pulse wave velocity (PWV) for each aorta: before stent graft deployment (t1); after deployment of a 100-mm long stent graft (t2); and after distal extension through deployment of a second 100-mm long stent graft (t3). Four different types of stent grafts (Conformable Gore® TAG® Device, Bolton Relay® Device, Cook Zenith Alpha™, and Medtronic Valiant®) were evaluated. RESULTS: For the total cohort of 20 aortas, PWV increased by a mean 0.6 m/s or 8.9% of baseline PWV after deployment of a 100-mm proximal stent graft (P<0.001), and by a mean 1.4 m/s or 23.0% of baseline PWV after distal extension of the stent graft (P<0.001). Univariable regression analysis showed a significant correlation between aortic PWV and extent of stent graft coverage, (P<0.001), but no significant effect of baseline aortic length, baseline aortic PWV, or stent graft type on the percentual increase in PWV at t2 or at t3. CONCLUSIONS: In this experimental set-up, aortic stiffness increased significantly after stent graft deployment with each of the four types of stent graft, with the increase in aortic stiffness depending on the extent of stent graft coverage.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0186080

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 62

Metadata

Authors
de Beaufort, H. W. L., Coda, M., Conti, M., van Bakel, T. M. J., Nauta, F. J. H., Lanzarone, E., Moll, F. L., van Herwaarden, J. A., Auricchio, F., & Trimarchi, S.
Venue
PLOS ONE
Published
2017-10-05
Volume
12
Issue
10
Pages
e0186080
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2763381053
Cited by
62
References
2
FWCI
5.87
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Changes in aortic pulse wave velocity of four thoracic aortic stent grafts in an ex vivo porcine model. https://app.cochat.ai/papers/10.1371/journal.pone.0186080
The paper
de Beaufort, H. W. L., Coda, M., Conti, M., van Bakel, T. M. J., Nauta, F. J. H., Lanzarone, E., Moll, F. L., van Herwaarden, J. A., Auricchio, F., & Trimarchi, S. (2017). Changes in aortic pulse wave velocity of four thoracic aortic stent grafts in an ex vivo porcine model. PLOS ONE. https://doi.org/10.1371/journal.pone.0186080

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.