Validity and reliability of GPS and LPS for measuring distances covered and sprint mechanical properties in team sports
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
This study aimed to investigate the validity and reliability of global (GPS) and local (LPS) positioning systems for measuring distances covered and sprint mechanical properties in team sports. Here, we evaluated two recently released 18 Hz GPS and 20 Hz LPS technologies together with one established 10 Hz GPS technology. Six male athletes (age: 27±2 years; VO2max: 48.8±4.7 ml/min/kg) performed outdoors on 10 trials of a team sport-specific circuit that was equipped with double-light timing gates. The circuit included various walking, jogging, and sprinting sections that were performed either in straight-lines or with changes of direction. During the circuit, athletes wore two devices of each positioning system. From the reported and filtered velocity data, the distances covered and sprint mechanical properties (i.e., the theoretical maximal horizontal velocity, force, and power output) were computed. The sprint mechanical properties were modeled via an inverse dynamic approach applied to the center of mass. The validity was determined by comparing the measured and criterion data via the typical error of estimate (TEE), whereas the reliability was examined by comparing the two devices of each technology (i.e., the between-device reliability) via the coefficient of variation (CV). Outliers due to measurement errors were statistically identified and excluded from validity and reliability analyses. The 18 Hz GPS showed better validity and reliability for determining the distances covered (TEE: 1.6-8.0%; CV: 1.1-5.1%) and sprint mechanical properties (TEE: 4.5-14.3%; CV: 3.1-7.5%) than the 10 Hz GPS (TEE: 3.0-12.9%; CV: 2.5-13.0% and TEE: 4.1-23.1%; CV: 3.3-20.0%). However, the 20 Hz LPS demonstrated superior validity and reliability overall (TEE: 1.0-6.0%; CV: 0.7-5.0% and TEE: 2.1-9.2%; CV: 1.6-7.3%). For the 10 Hz GPS, 18 Hz GPS, and 20 Hz LPS, the relative loss of data sets due to measurement errors was 10.0%, 20.0%, and 15.8%, respectively. This study shows that 18 Hz GPS has enhanced validity and reliability for determining movement patterns in team sports compared to 10 Hz GPS, whereas 20 Hz LPS had superior validity and reliability overall. However, compared to 10 Hz GPS, 18 Hz GPS and 20 Hz LPS technologies had more outliers due to measurement errors, which limits their practical applications at this time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Progressive Statistics for Studies in Sports Medicine and Exercise Science
HOPKINS, W. G., MARSHALL, S. W., BATTERHAM, A. M., & HANIN, J. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31818cb278 · Cited by 9,128
Physiology of Soccer: An Update
St??len, T., Chamari, K., Castagna, C., & Wisl??ff, U. (2005) · Sports Medicine · doi:10.2165/00007256-200535060-00004 · Cited by 2,325
Varley, M. C., Fairweather, I. H., & Aughey, R. J. (2012) · Journal of Sports Sciences · doi:10.1080/02640414.2011.627941 · Cited by 646 · cited 1×
“Considering the reliability and validity for determining team sport-specific movement patterns, previous research has shown that 5 Hz devices were superior than 1 Hz devices [27, 34] and 10 Hz devices were superior than 5 Hz devices [11, 48], whereas 15 Hz devices were unexpectedly not superior to 10 Hz devices [10, 1…”
BackgroundValidity and reliability of GPS devices for measuring movement demands of team sports
Coutts, A. J., & Duffield, R. (2010) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2008.09.015 · Cited by 645
Unpacking the Black Box: Applications and Considerations for Using GPS Devices in Sport
Malone, J. J., Lovell, R., Varley, M. C., & Coutts, A. J. (2017) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2016-0236 · Cited by 582 · cited 9×
“, filtering techniques applied to the raw data) [16], more research comparing the validity and reliability between GPS and LPS for determining team sport-specific movement patterns is required [6].”
BackgroundMethodInfluentialThe Validity and Reliability of Global Positioning Systems in Team Sport: A Brief Review
Scott, M. T. U., Scott, T. J., & Kelly, V. G. (2016) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001221 · Cited by 509 · cited 9×
“The 10 Hz devices were chosen as a representative GPS standard because these devices are frequently used in team sport practice and applied studies [33] and in numerous previous validation studies [12], which collectively showed that these devices currently allow the most valid and reliable GPS assessment of team spor…”
BackgroundMethodInfluentialInterpreting Power-Force-Velocity Profiles for Individualized and Specific Training
Morin, J.-B., & Samozino, P. (2016) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2015-0638 · Cited by 505
Samozino, P., Rabita, G., Dorel, S., Slawinski, J., Peyrot, N., Saez de Villarreal, E., & Morin, J. ‐. (2016) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.12490 · Cited by 497 · cited 9×
“Then, the theoretical horizontal power output (P) at each instance was computed as follows [20]:”
BackgroundMethodResultInfluentialApplications of GPS Technologies to Field Sports
Aughey, R. J. (2011) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.6.3.295 · Cited by 468 · cited 1×
“As a replacement, global (GPS) [3] and also local (LPS) [4] positioning systems have become standard tools for determining movement patterns during matches and training sessions [5, 6].”
BackgroundJohnston, R. J., Watsford, M. L., Kelly, S. J., Pine, M. J., & Spurrs, R. W. (2014) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000000323 · Cited by 447 · cited 3×
“Considering the reliability and validity for determining team sport-specific movement patterns, previous research has shown that 5 Hz devices were superior than 1 Hz devices [27, 34] and 10 Hz devices were superior than 5 Hz devices [11, 48], whereas 15 Hz devices were unexpectedly not superior to 10 Hz devices [10, 1…”
BackgroundMethodResult
Cited by
Beato, M., Coratella, G., Stiff, A., & Iacono, A. D. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.01288 · Cited by 256
Metadata
- Authors
- Hoppe, M. W., Baumgart, C., Polglaze, T., & Freiwald, J.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2018-02-08
- Volume
- 13
- Issue
- 2
- Pages
- e0192708
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2786199355
- Cited by
- 237
- References
- 41
- FWCI
- 22.61
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.