DeepFocus: Detection of out-of-focus regions in whole slide digital images using deep learning
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The development of whole slide scanners has revolutionized the field of digital pathology. Unfortunately, whole slide scanners often produce images with out-of-focus/blurry areas that limit the amount of tissue available for a pathologist to make accurate diagnosis/prognosis. Moreover, these artifacts hamper the performance of computerized image analysis systems. These areas are typically identified by visual inspection, which leads to a subjective evaluation causing high intra- and inter-observer variability. Moreover, this process is both tedious, and time-consuming. The aim of this study is to develop a deep learning based software called, DeepFocus, which can automatically detect and segment blurry areas in digital whole slide images to address these problems. DeepFocus is built on TensorFlow, an open source library that exploits data flow graphs for efficient numerical computation. DeepFocus was trained by using 16 different H&E and IHC-stained slides that were systematically scanned on nine different focal planes, generating 216,000 samples with varying amounts of blurriness. When trained and tested on two independent datasets, DeepFocus resulted in an average accuracy of 93.2% (± 9.6%), which is a 23.8% improvement over an existing method. DeepFocus has the potential to be integrated with whole slide scanners to automatically re-scan problematic areas, hence improving the overall image quality for pathologists and image analysis algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
TensorFlow: Large-Scale Machine Learning on Heterogeneous Distributed Systems
Abadi, M., Agarwal, A., Barham, P., Brevdo, E., Chen, Z., Citro, C., Corrado, G. S., Davis, A., Dean, J., Devin, M., et al. (2016) · arXiv · doi:10.48550/arxiv.1603.04467 · Cited by 9,408
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
Practical Recommendations for Gradient-Based Training of Deep Architectures
Bengio, Y. (2012) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-35289-8_26 · Cited by 2,259
Neural Networks: Tricks of the Trade: Second Edition
(2012) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-35289-8 · Cited by 2,116
Deep learning as a tool for increased accuracy and efficiency of histopathological diagnosis
Litjens, G., Sánchez, C. I., Timofeeva, N., Hermsen, M., Nagtegaal, I., Kovacs, I., Hulsbergen - van de Kaa, C., Bult, P., van Ginneken, B., & van der Laak, J. (2016) · Scientific Reports · doi:10.1038/srep26286 · Cited by 1,069
Cited by
Artificial intelligence in digital pathology — new tools for diagnosis and precision oncology
Bera, K., Schalper, K. A., Rimm, D. L., Velcheti, V., & Madabhushi, A. (2019) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-019-0252-y · Cited by 1,698
Digital pathology and artificial intelligence
Niazi, M. K. K., Parwani, A. V., & Gurcan, M. N. (2019) · The Lancet Oncology · doi:10.1016/s1470-2045(19)30154-8 · Cited by 1,232
“Because DeepFocus automatically learns features at different levels of abstraction, it can generalize to different types of tissues and even to color variations due to different types of staining, H&E and IHC.”
BackgroundInfluentialSelf-citationArtificial intelligence and computational pathology
Cui, M., & Zhang, D. Y. (2021) · Laboratory Investigation · doi:10.1038/s41374-020-00514-0 · Cited by 544
“[22] described a novel deep-learning framework, called DeepFocus, which enables the automatic identification of blurry regions in digital slides for immediate re-scan in order to improve image quality for pathologists and image analysis algorithms.”
BackgroundArtificial intelligence in oncology
Shimizu, H., & Nakayama, K. I. (2020) · Cancer Science · doi:10.1111/cas.14377 · Cited by 388
“34 Some automated CNN-based tools, such as HistoQC and DeepFocus, 35,36 have been developed to standardize the quality of whole-slide imaging.”
MethodHistoQC: An Open-Source Quality Control Tool for Digital Pathology Slides
Janowczyk, A., Zuo, R., Gilmore, H., Feldman, M., & Madabhushi, A. (2019) · JCO Clinical Cancer Informatics · doi:10.1200/cci.18.00157 · Cited by 355
Quality control stress test for deep learning-based diagnostic model in digital pathology
Schömig-Markiefka, B., Pryalukhin, A., Hulla, W., Bychkov, A., Fukuoka, J., Madabhushi, A., Achter, V., Nieroda, L., Büttner, R., Quaas, A., et al. (2021) · Modern Pathology · doi:10.1038/s41379-021-00859-x · Cited by 146
Generative Artificial Intelligence in Anatomic Pathology
Brodsky, V., Ullah, E., Bychkov, A., Song, A. H., Walk, E. E., Louis, P., Rasool, G., Singh, R. S., Mahmood, F., Bui, M. M., et al. (2025) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2024-0215-ra · Cited by 48
Metadata
- Authors
- Senaras, C., Niazi, M. K. K., Lozanski, G., & Gurcan, M. N.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2018-10-25
- Volume
- 13
- Issue
- 10
- Pages
- e0205387
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2898181981
- Cited by
- 121
- References
- 6
- FWCI
- 6.51
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.