CoChat

The influence of subretinal injection pressure on the microstructure of the monkey retina

Open access
Takahashi, Kosuke, Morizane, Yuki, Hisatomi, Toshio, Tachibana, Takashi, Kimura, Shuhei, Hosokawa, Mio Morizane, Shiode, Yusuke, Hirano, Masayuki, Doi, Shinichiro, Toshima, Shinji, Araki, Ryoichi, Matsumae, Hiroshi, Kanzaki, Yuki, Hosogi, Mika, Yoshida, Atsushi, Sonoda, Koh-Hei, Shiraga, Fumio · 2018 · PLOS ONE
Cited by 37

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

PURPOSE: To investigate the influence of subretinal injection pressure on the microstructure of the retina in a monkey model. METHODS: After vitrectomy, balanced salt solution was injected subretinally into one eye each of four cynomolgus monkeys while controlling the injection pressure. Initially, a pressure of 2 psi was used, and this was gradually increased to determine the minimum required pressure. Subsequent injections were performed at two pressures: minimum (n = 13) and high (n = 6). To compare the influence of these injection pressures on retinal structure, optical coherence tomography (OCT) was performed before surgery and every week afterwards. The monkeys were euthanized and their eyes were enucleated at 1 or 6 weeks after the injections. The eyes were processed for light microscopy and transmission electron microscopy (TEM) as well as for TdT-mediated dUTP nick end labeling. RESULTS: The minimum pressure required to perform subretinal injection was 6 psi. After injection at this pressure, both OCT and microscopy showed that the retinal structure was well-preserved throughout the experimental period at all injection sites. Conversely, after injection at high pressure (20 psi) OCT images at all injection sites showed disruption of the ellipsoid zone (EZ) after 1 week. Microscopy indicated damage to the photoreceptor outer segment (OS) and stratification of the retinal pigment epithelium (RPE). After 6 weeks, OCT demonstrated that the EZ had become continuous and TEM confirmed that the OS and RPE had recovered. Photoreceptor apoptosis was absent after subretinal injection at both pressures. CONCLUSIONS: The retinal damage caused by subretinal injection increases depending on pressure, indicating that clinicians should perform subretinal injection at pressures as low as possible to ensure safety.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0209996

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 37

Metadata

Authors
Takahashi, K., Morizane, Y., Hisatomi, T., Tachibana, T., Kimura, S., Hosokawa, M. M., Shiode, Y., Hirano, M., Doi, S., Toshima, S., Araki, R., Matsumae, H., Kanzaki, Y., Hosogi, M., Yoshida, A., Sonoda, K.-H., & Shiraga, F.
Venue
PLOS ONE
Published
2018-12-31
Volume
13
Issue
12
Pages
e0209996
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2908175873
Cited by
37
References
9
FWCI
2.45
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The influence of subretinal injection pressure on the microstructure of the monkey retina. https://app.cochat.ai/papers/10.1371/journal.pone.0209996
The paper
Takahashi, K., Morizane, Y., Hisatomi, T., Tachibana, T., Kimura, S., Hosokawa, M. M., Shiode, Y., Hirano, M., Doi, S., Toshima, S., Araki, R., Matsumae, H., Kanzaki, Y., Hosogi, M., Yoshida, A., Sonoda, K.-H., & Shiraga, F. (2018). The influence of subretinal injection pressure on the microstructure of the monkey retina. PLOS ONE. https://doi.org/10.1371/journal.pone.0209996

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.