Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Microstructure imaging techniques based on tensor-valued diffusion encoding have gained popularity within the MRI research community. Unlike conventional diffusion encoding-applied along a single direction in each shot-tensor-valued encoding employs diffusion encoding along multiple directions within a single preparation of the signal. The benefit is that such encoding may probe tissue features that are not accessible by conventional encoding. For example, diffusional variance decomposition (DIVIDE) takes advantage of tensor-valued encoding to probe microscopic diffusion anisotropy independent of orientation coherence. The drawback is that tensor-valued encoding generally requires gradient waveforms that are more demanding on hardware; it has therefore been used primarily in MRI systems with relatively high performance. The purpose of this work was to explore tensor-valued diffusion encoding on clinical MRI systems with varying performance to test its technical feasibility within the context of DIVIDE. We performed whole-brain imaging with linear and spherical b-tensor encoding at field strengths between 1.5 and 7 T, and at maximal gradient amplitudes between 45 and 80 mT/m. Asymmetric gradient waveforms were optimized numerically to yield b-values up to 2 ms/μm2. Technical feasibility was assessed in terms of the repeatability, SNR, and quality of DIVIDE parameter maps. Variable system performance resulted in echo times between 83 to 115 ms and total acquisition times of 6 to 9 minutes when using 80 signal samples and resolution 2×2×4 mm3. As expected, the repeatability, signal-to-noise ratio and parameter map quality depended on hardware performance. We conclude that tensor-valued encoding is feasible for a wide range of MRI systems-even at 1.5 T with maximal gradient waveform amplitudes of 33 mT/m-and baseline experimental design and quality parameters for all included configurations. This demonstrates that tissue features, beyond those accessible by conventional diffusion encoding, can be explored on a wide range of MRI systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970 · cited 6×
“Methods such as diffusion tensor imaging (DTI) (Basser et al., 1994) yield parameters which are sensitive to alterations of the tissue microstructure in both healthy development and disease (Assaf and Pasternak, 2008).”
InfluentialElastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311 · cited 1×
“Diffusion weighted data was corrected for motion and eddy-currents in Elastix (Klein et al., 2010) using an extrapolation-based reference volume (Nilsson et al., 2015).”
Basser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912 · cited 1×
“The minimal b-value ( b min ) is commonly set to zero, however, to reduce the influence of incoherent intra-voxel motion (Le Bihan et al., 1986), we set b min = 0.1 ms/µm 2 .”
InfluentialJensen, J. H., Helpern, J. A., Ramani, A., Lu, H., & Kaczynski, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20508 · Cited by 2,488 · cited 7×
“However, DTI and DKI, along with the vast majority of other dMRI techniques, are based on so-called single diffusion encoding (SDE), i.e. a pair of pulsed gradients that encode for diffusion along a single direction per acquisition (Stejskal and Tanner, 1965).”
InfluentialDiffusion tensor imaging (DTI)-based white matter mapping in brain research: a review
Assaf, Y., & Pasternak, O. (2008) · Journal of Molecular Neuroscience · doi:10.1007/s12031-007-0029-0 · Cited by 1,537 · cited 1×
“Methods such as diffusion tensor imaging (DTI) (Basser et al., 1994) yield parameters which are sensitive to alterations of the tissue microstructure in both healthy development and disease (Assaf and Pasternak, 2008).”
MRI quantification of non-gaussian water diffusion by kurtosis analysis
Jensen, J. H., & Helpern, J. A. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1518 · Cited by 1,251 · cited 3×
“We used the inverse Laplace transform of the gamma distribution as a signal model (Jensen and Helpern, 2010, Röding et al., 2012), in accordance with previous implementations (Lasič et al., 2014, Szczepankiewicz et al., 2015).”
Moffat, B. A., Chenevert, T. L., Lawrence, T. S., Meyer, C. R., Johnson, T. D., Dong, Q., Tsien, C., Mukherji, S., Quint, D. J., Gebarski, S. S., et al. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0501532102 · Cited by 643
An analytical model of restricted diffusion in bovine optic nerve
Stanisz, G. J., Wright, G. A., Henkelman, R. M., & Szafer, A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370115 · Cited by 501 · cited 1×
“The diffusion process has been shown to be time-dependent in biological tissues using specialized diffusion encoding schemes (Stanisz et al., 1997, Assaf et al., 2000, Does et al., 2003, Fieremans et al., 2016), and in pathological tissue (Lätt et al., 2009).”
Cited by
Figley, C. R., Uddin, M. N., Wong, K., Kornelsen, J., Puig, J., & Figley, T. D. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.799576 · Cited by 253
Multidimensional diffusion MRI
Topgaard, D. (2017) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2016.12.007 · Cited by 220
Searching for the neurite density with diffusion MRI: challenges for biophysical modeling
Lampinen, B., Szczepankiewicz, F., Novén, M., van Westen, D., Hansson, O., Englund, E., Mårtensson, J., Westin, C., & Nilsson, M. (2019) · Human Brain Mapping · doi:10.1002/hbm.24542 · Cited by 123
Self-citationLampinen, B., Szczepankiewicz, F., Mårtensson, J., van Westen, D., Hansson, O., Westin, C., & Nilsson, M. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28216 · Cited by 86
Self-citationLampinen, B., Szczepankiewicz, F., Lätt, J., Knutsson, L., Mårtensson, J., Björkman-Burtscher, I. M., van Westen, D., Sundgren, P. C., Ståhlberg, F., & Nilsson, M. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120338 · Cited by 38
Self-citation
Metadata
- Authors
- Szczepankiewicz, F., Sjölund, J., Ståhlberg, F., Lätt, J., & Nilsson, M.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2019-03-28
- Volume
- 14
- Issue
- 3
- Pages
- e0214238
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2930043270
- Cited by
- 104
- References
- 15
- FWCI
- 9.00
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems. https://app.cochat.ai/papers/10.1371/journal.pone.0214238
- The paper
- Szczepankiewicz, F., Sjölund, J., Ståhlberg, F., Lätt, J., & Nilsson, M. (2019). Tensor-valued diffusion encoding for diffusional variance decomposition (DIVIDE): Technical feasibility in clinical MRI systems. PLOS ONE. https://doi.org/10.1371/journal.pone.0214238
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.