Cited by 21Cardiovascular and exercise physiologySports Performance and TrainingPhysical Activity and Health

Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise?

Open access
Reis, Victor M., Vianna, Jeferson M., Barbosa, Tiago M., Garrido, Nuno, Vilaça Alves, Jose, Carneiro, André L., Aidar, Felipe J., Novaes, Jefferson·2019·PLOS ONE

Abstract

The aim of the present study was to assess the accuracy of heart rate to estimate energy cost during eight resistance exercises performed at low intensities: half squat, 45° inclined leg press, leg extension, horizontal bench press, 45° inclined bench press, lat pull down, triceps extension and biceps curl. 56 males (27.5 ± 4.9 years, 1.78 ± 0.06 m height, 78.67 ± 10.7 kg body mass and 11.4 ± 4.1% estimated body fat) were randomly divided into four groups of 14 subjects each. Two exercises were randomly assigned to each group and subjects performed four bouts of 4-min constant-intensity at each assigned exercise: 12%, 16%, 20% and 24% 1-RM. Exercise and intensity order were random. Each subject performed no more than 2 bouts in the same testing session. A minimum recovery of 24h was kept between sessions. During testing VO2 was measured with Cosmed K4b2 and heart rate was measured with Polar V800 monitor. Energy cost was calculated from mean VO2 during the last 30-s of each bout by using the energy equivalent 1 ml O2 = 5 calorie. Linear regressions with heart rate as predictor and energy cost as dependent variable were build using mean data from all subjects. Robustness of the regression lines was given by the scatter around the regression line (Sy.x) and Bland-Altman plots confirmed the agreement between measured and estimated energy costs. Significance level was set at p≤0.05. The regressions between heart rate and energy cost in the eight exercises were significant (p<0.01) and robustness was: half squat (Sy.x = 0,48 kcal·min-1), 45° inclined leg press (Sy.x = 0,54 kcal·min-1), leg extension (Sy.x = 0,59 kcal·min-1), horizontal bench press (Sy.x = 0,47 kcal·min-1), 45° inclined bench press (Sy.x = 0,54 kcal·min-1), lat pull down (Sy.x = 0,28 kcal·min-1), triceps extension (Sy.x = 0,08 kcal·min-1) and biceps curl (Sy.x = 0,13 kcal·min-1). We conclude that during low-intensity resistance exercises it is possible to estimate aerobic energy cost by wearable heart rate monitors with errors below 10% in healthy young trained males.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0221284

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Heart rate measurements from wearable devices are often less accurate during physical activity or cyclic wrist motions.

    “Several studies have demonstrated that HR measurements from wearable devices are often less accurate during physical activity or cyclic wrist motions.”

    From Investigating sources of inaccuracy in wearable optical heart rate sensors (2020) · cites this paper as [39]

    The Discussion reports that some wearable HR devices had errors above 10% when used to predict energy cost during higher-intensity resistance exercise, while this study found errors below 10% at low intensity. That supports a narrower, activity-dependent concern about energy-cost estimates, not the claim that HR measurements themselves are often less accurate during physical activity; the paper does not address cyclic wrist motions. Our copy provides no page numbers for these passages. (LLM, conf=0.82)

    Experimental — accuracy not yet measured
  • Wearable devices have higher error during activity than at rest.

    “Our analyses reinforces the growing body of research demonstrating that wearable devices have higher error during activity than at rest.8,11,35,38,39”

    From Investigating sources of inaccuracy in wearable optical heart rate sensors (2020) · cites this paper as [39]

    The Results and Conclusions report estimation errors during low-intensity resistance exercise, but do not compare them with errors at rest. A search for resting measurements and an activity-versus-rest accuracy comparison found no passage addressing that comparison in our copy. (LLM, conf=0.76)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 16 references couldn’t be matched to a known paper.

Research works printed but not linked: 3

  1. [5]Oliveira JC, Baldissera V, Simões HG, Aguiar AP, Azevedo P, Poian P et al Identification of the lactate threshold and the blood glucose threshold in resistance exercise. Braz J Sports Med. 2006; 12: 333– 338.
  2. [6]Rocha RM, Bomfim DL, Nascimento TB, Moreira SR, Simões HG. Variation in the incremental workload method does not change the lactate threshold determination in resistance exercise. Braz J Sports Med. 2010; 16: 282– 285.
  3. [9]Kraemer WJ, Fry AC. Strength testing: development and evaluation of methodology In: Maud P and Nieman DC, editors. Fitness and sports medicine: a health-related approach. Palo Alto: Bull Publishing; 1995 pp. 115– 138.

Cited by

Sorted by citations

Authors
Reis, V. M., Vianna, J. M., Barbosa, T. M., Garrido, N., Vilaça Alves, J., Carneiro, A. L., Aidar, F. J., & Novaes, J.
Affiliations
  • Nanyang Technological University (SG)
  • University of Trás-os-Montes and Alto Douro (PT)
  • Universidade Estadual de Montes Claros (BR)
  • Universidade Federal de Sergipe (BR)
  • Universidade Federal de Juiz de Fora (BR)
Venue
PLOS ONE
Published
2019-08-22
Volume
14
Issue
8
Pages
e0221284
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2969220010
Cited by
21
References
16
Citations by year
2026: 2 · 2024: 4 · 2023: 3 · 2022: 1 · 2021: 5 · 2020: 6
FWCI
3.87
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
  • Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) (submittedVersion, other-oa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Norte 2020 (NanoSTIMA, NORTE-01-0145- FEDER-000016)
Topics
  • Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Physiology › Physical Activity and Health
Keywords
heart rate monitoring, wearable heart rate monitor, resistance training, low-intensity exercise, energy expenditure estimation, VO2, exercise intensity, half squat, bench press, leg press, triceps extension, biceps curl, lat pull-down, leg extension, energy equivalents, Bland-Altman agreement, smartwatches
MeSH terms
Wearable Electronic Devices, Adult, Energy Metabolism, Heart Rate, Humans, Male, Monitoring, Physiologic, Oxygen Consumption, Linear Models, Muscle, Skeletal, Resistance Training

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review