Validity of Wearable Activity Monitors during Cycling and Resistance Exercise
Abstract
INTRODUCTION: The use of wearable activity monitors has seen rapid growth; however, the mode and intensity of exercise could affect the validity of heart rate (HR) and caloric (energy) expenditure (EE) readings. There is a lack of data regarding the validity of wearable activity monitors during graded cycling regimen and a standard resistance exercise. The present study determined the validity of eight monitors for HR compared with an ECG and seven monitors for EE compared with a metabolic analyzer during graded cycling and resistance exercise. METHODS: Fifty subjects (28 women, 22 men) completed separate trials of graded cycling and three sets of four resistance exercises at a 10-repetition-maximum load. Monitors included the following: Apple Watch Series 2, Fitbit Blaze, Fitbit Charge 2, Polar H7, Polar A360, Garmin Vivosmart HR, TomTom Touch, and Bose SoundSport Pulse (BSP) headphones. HR was recorded after each cycling intensity and after each resistance exercise set. EE was recorded after both protocols. Validity was established as having a mean absolute percent error (MAPE) value of ≤10%. RESULTS: The Polar H7 and BSP were valid during both exercise modes (cycling: MAPE = 6.87%, R = 0.79; resistance exercise: MAPE = 6.31%, R = 0.83). During cycling, the Apple Watch Series 2 revealed the greatest HR validity (MAPE = 4.14%, R = 0.80). The BSP revealed the greatest HR accuracy during resistance exercise (MAPE = 6.24%, R = 0.86). Across all devices, as exercise intensity increased, there was greater underestimation of HR. No device was valid for EE during cycling or resistance exercise. CONCLUSIONS: HR from wearable devices differed at different exercise intensities; EE estimates from wearable devices were inaccurate. Wearable devices are not medical devices, and users should be cautious when using these devices for monitoring physiological responses to exercise.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
HR and EE measured by both the Garmin and Fitbit devices during the resistance exercise were similar to the measurements reported by Boudreaux et al.
“In results presented in this paper, HR and EE measured by both the Garmin and Fitbit devices during the resistance exercise were similar to the measurements reported by Boudreaux et al [24].”
From Accuracy of Wrist-Worn Activity Monitors During Common Daily Physical Activities and Types of Structured Exercise: Evaluation Study (2018) · cites this paper as [24]
Presently, there are at least four studies that have investigated the accuracy of wearable devices during resistance exercises and none during high-intensity interval training.
“Presently, there are at least 4 studies [21-24] that have investigated the accuracy of wearable devices during resistance exercises and none during HIIT training.”
From Accuracy of Wrist-Worn Activity Monitors During Common Daily Physical Activities and Types of Structured Exercise: Evaluation Study (2018) · cites this paper as [24]
Bourdreaux et al showed that energy expenditure measured by the devices was poor, with mean absolute percent error values ranging between 43% and 57%.
“They also showed that the EE measured by the devices was poor, with MAPE values ranging between 43% and 57%.”
From Accuracy of Wrist-Worn Activity Monitors During Common Daily Physical Activities and Types of Structured Exercise: Evaluation Study (2018) · cites this paper as [24]
Bourdreaux et al demonstrated that heart rate measured by nonwrist worn devices was relatively accurate, whereas wrist-worn devices showed poor correlations (R<.8) and higher error during resistance exercises (mean absolute percent error >9%).
“Results from this study demonstrated that HR measured by nonwrist worn devices were relatively accurate, whereas wrist-worn devices showed poor correlations (R<.8) and higher error during resistance exercises (mean absolute percent error [MAPE] >9%).”
From Accuracy of Wrist-Worn Activity Monitors During Common Daily Physical Activities and Types of Structured Exercise: Evaluation Study (2018) · cites this paper as [24]
The Polar H7 was the most valid and reliable device and the only device that was valid and reliable during all different levels of exercise intensity.
“The Polar H7 was compared to other HR monitoring devices, as Apple Watch Series, Fitbit or Garmin Vivosmart HR, and the results proved that it was not only the most valid and reliable device, but also the only device that was valid and reliable during all different levels of exercise intensity (Boudreaux et al., 2018).”
From The relationship of muscle oxygen saturation analyzer with other monitoring and quantification tools in a maximal incremental treadmill test (2023) · cites this paper as Boudreaux et al., 2018
Some studies have used the gold-standard reference method of electrocardiogram, which directly measures heart rate via electrical impulses from the heart and is used for clinical accuracy.
“Although some studies have attempted to address wearable HR accuracy using the gold-standard reference method of ECG, which directly measures HR via electrical impulses from the heart and is used for clinical accuracy38–44”
From Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research (2020) · cites this paper as [39]
Apple Watch has lower mean difference standard deviation and higher agreement with electrocardiogram than Fitbit devices.
“lower mean difference standard deviation43, and higher agreement with ECG than Fitbit devices39,44.”
From Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research (2020) · cites this paper as [39]
Apple Watch models have lower overall error (1.20 to 6.70%) than Fitbit models (2.38 to 21.36%).
“as well as lower overall error with the Apple Watch models ranging from 1.20 to 6.70% error and Fitbit models ranging from 2.38 to 21.36% error39,42,45”
From Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research (2020) · cites this paper as [39]
Wrist placement, tightness of device, dominant vs non-dominant hand use, and degree of wrist movement have consistently been shown to influence the accuracy of heart rate measurement.
“In addition to wrist circumference, there are a number of other factors including wrist placement, tightness of device, dominant vs non-dominant hand use, and degree of wrist movement that have consistently been shown to influence the accuracy of HR measurement39”
From Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research (2020) · cites this paper as [39]
Wearable devices are more accurate during rest and low intensity exercise compared to higher intensity exercise, when they can begin to deviate more from ECG recordings.
“a substantial amount of research showing that wearable devices are more accurate during rest and low intensity exercise when compared to higher intensity exercise, when wearable devices can begin to deviate more from ECG recordings38,39,44,46,70–73”
From Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research (2020) · cites this paper as [39]
Cites
DONNELLY, J. E., BLAIR, S. N., JAKICIC, J. M., MANORE, M. M., RANKIN, J. W., & SMITH, B. K. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181949333 · Cited by 2,658 · see citing works
Achten, J., & Jeukendrup, A. E. (2003) · Sports Medicine · doi:10.2165/00007256-200333070-00004 · Cited by 1,202 · see citing works
Validity of Consumer-Based Physical Activity Monitors
LEE, J.-M., KIM, Y., & WELK, G. J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000287 · Cited by 401 · cited 1× · see citing works
“Findings from this study support previous research (11,22,23,29) that wearable devices may not be accurate for measurement of EE during physical activity.”
ResultAccuracy of wrist-worn heart rate monitors
Wang, R., Blackburn, G., Desai, M., Phelan, D., Gillinov, L., Houghtaling, P., & Gillinov, M. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2016.3340 · Cited by 386 · see citing works
Variable Accuracy of Wearable Heart Rate Monitors during Aerobic Exercise
GILLINOV, S., ETIWY, M., WANG, R., BLACKBURN, G., PHELAN, D., GILLINOV, A. M., HOUGHTALING, P., JAVADIKASGARI, H., & DESAI, M. Y. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001284 · Cited by 345 · see citing works
Accuracy of Heart Rate Watches: Implications for Weight Management
Wallen, M. P., Gomersall, S. R., Keating, S. E., Wisløff, U., & Coombes, J. S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154420 · Cited by 336 · see citing works
How consumer physical activity monitors could transform human physiology research
Wright, S. P., Hall Brown, T. S., Collier, S. R., & Sandberg, K. (2017) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00349.2016 · Cited by 234 · see citing works
Reliability and Validity of Ten Consumer Activity Trackers Depend on Walking Speed
Fokkema, T., Kooiman, T. J. M., Krijnen, W. P., van der Schans, C. P., & de Groot, M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001146 · Cited by 212 · see citing works
The advantages of wearable green reflected photoplethysmography
Maeda, Y., Sekine, M., & Tamura, T. (2011) · Journal of Medical Systems · doi:10.1007/s10916-010-9506-z · Cited by 209 · see citing works
Validity of Consumer-Based Physical Activity Monitors for Specific Activity Types
Nelson, M. B., Kaminsky, L. A., Dickin, D. C., & Montoye, A. H. K. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000933 · Cited by 206 · see citing works
Comparison of Consumer and Research Monitors under Semistructured Settings
BAI, Y., WELK, G. J., NAM, Y. H., LEE, J. A., LEE, J.-M., KIM, Y., MEIER, N. F., & DIXON, P. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000727 · Cited by 149 · see citing works
WORLDWIDE SURVEY OF FITNESS TRENDS FOR 2017
Thompson, W. R. (2016) · ACSMʼs Health & Fitness Journal · doi:10.1249/fit.0000000000000252 · Cited by 147 · see citing works
Department of Clinical and Digital Health Sciences, C. O. A. H. S., Coughlin, S. S., & Stewart, J. (2016) · Journal of Environment and Health Science · doi:10.15436/2378-6841.16.1123 · Cited by 137 · see citing works
Wearable Sensing for Solid Biomechanics
Wong, C., Zhang, Z., Lo, B. P. L., & Yang, G. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2393883 · Cited by 110 · see citing works
Hormonal Responses from Concentric and Eccentric Muscle Contractions
DURAND, R. J., Castracane, V. D., HOLLANDER, D. B., Tryniecki, J. L., Bamman, M. M., NEAL, S. O., HEBERT, E. P., & Kraemer, R. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000069522.38141.0b · Cited by 110 · see citing works
Self-citationWORLDWIDE SURVEY OF FITNESS TRENDS FOR 2016
Thompson, W. R. (2015) · ACSMʼs Health & Fitness Journal · doi:10.1249/fit.0000000000000164 · Cited by 108 · see citing works
Comparison of Polar M600 Optical Heart Rate and ECG Heart Rate during Exercise
HORTON, J. F., STERGIOU, P., FUNG, T. S., & KATZ, L. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001388 · Cited by 79 · see citing works
Sedentary Behavior, Cadence, and Physical Activity Outcomes after Knee Arthroplasty
Webber, S. C., Strachan, S. M., & Pachu, N. S. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001207 · Cited by 48 · see citing works
Butler, M. J., Crowe, J. A., Hayes‐Gill, B., & Rodmell, P. I. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/5/n27 · Cited by 45 · see citing works
Earbud-Based Sensor for the Assessment of Energy Expenditure, HR, and V˙O2max
LeBoeuf, S., Aumer, M. E., Kraus, W. E., Johnson, J. L., & Duscha, B. D. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000183 · Cited by 41 · see citing works
Effects of skin surface temperature on photoplethysmograph
Jeong, I. C., Yoon, H., Kang, H., & Yeom, H. (2014) · Journal of Healthcare Engineering · doi:10.1260/2040-2295.5.4.429 · Cited by 33 · see citing works
Set Configuration in Resistance Exercise: Muscle Fatigue and Cardiovascular Effects
Río-Rodríguez, D., Iglesias‐Soler, E., & Fernández‐del‐Olmo, M. (2016) · PLoS ONE · doi:10.1371/journal.pone.0151163 · Cited by 31 · see citing works
Wearable Technology Reduces Prolonged Bouts of Sedentary Behavior
Ellingson, L. D., Meyer, J. D., & Cook, D. B. (2016) · Translational Journal of the American College of Sports Medicine · doi:10.1249/tjx.0000000000000001 · Cited by 24 · see citing works
Energy Balance at a Crossroads
Manore, M. M., Brown, K. A., HOUTKOOPER, L. B., Jakicic, J. M., Peters, J. C., Edge, M. S., Steiber, A. L., Going, S. B., Gable, L. G., & Krautheim, A. M. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000318 · Cited by 20 · see citing works
Rafolt, D., & Gallasch, E. (2004) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2004.005 · Cited by 19 · see citing works
Piirainen, J. M., Tanskanen, M., Nissilä, J., Kaarela, J., Väärälä, A., Sippola, N., & Linnamo, V. (2011) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181ecd050 · Cited by 11 · see citing works
Hetrick, M. M., Naquin, M. R., Gillan, W., Williams, B. M., & Kraemer, R. R. (2017) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001856 · Cited by 4 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715 · see citing works
Nelson, B. W., & Allen, N. B. (2019) · JMIR mHealth and uHealth · doi:10.2196/10828 · Cited by 310 · see citing works
How to use digital devices to detect and manage arrhythmias: an EHRA practical guide
Svennberg, E., Tjong, F., Goette, A., Akoum, N., Di Biase, L., Bordachar, P., Boriani, G., Burri, H., Conte, G., Deharo, J. C., et al. (2022) · Europace · doi:10.1093/europace/euac038 · Cited by 261 · see citing works
Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research
Nelson, B. W., Low, C. A., Jacobson, N., Areán, P., Torous, J., & Allen, N. B. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0297-4 · Cited by 241 · see citing works
Reddy, R. K., Pooni, R., Zaharieva, D. P., Senf, B., El Youssef, J., Dassau, E., Doyle III, F. J., Clements, M. A., Rickels, M. R., Patton, S. R., et al. (2018) · JMIR mHealth and uHealth · doi:10.2196/10338 · Cited by 157 · see citing works
Falter, M., Budts, W., Goetschalckx, K., Cornelissen, V., & Buys, R. (2019) · JMIR mHealth and uHealth · doi:10.2196/11889 · Cited by 142 · see citing works
Chow, H.-W., & Yang, C.-C. (2020) · JMIR mHealth and uHealth · doi:10.2196/14707 · Cited by 140 · see citing works
“For instance, Gillinov et al [2] set the CCC value greater than 0.80 to represent acceptable reliability, whereas Boudreaux et al [13] set ICC values from 0.60 to 0.75 to represent moderate reliability and from 0.75 to 0.90 to indicate superior reliability.”
InfluentialZhang, Y., Weaver, R. G., Armstrong, B., Burkart, S., Zhang, S., & Beets, M. W. (2020) · Journal of Sports Sciences · doi:10.1080/02640414.2020.1767348 · Cited by 88 · see citing works
Validation of a Photoplethysmographic Heart Rate Monitor: Polar OH1
Hermand, E., Cassirame, J., Ennequin, G., & Hue, O. (2019) · International Journal of Sports Medicine · doi:10.1055/a-0875-4033 · Cited by 59 · see citing works
Vetrovsky, T., Siranec, M., Marencakova, J., Tufano, J. J., Capek, V., Bunc, V., & Belohlavek, J. (2019) · PLOS ONE · doi:10.1371/journal.pone.0222569 · Cited by 53 · see citing works
Reis, V. M., Vianna, J. M., Barbosa, T. M., Garrido, N., Vilaça Alves, J., Carneiro, A. L., Aidar, F. J., & Novaes, J. (2019) · PLOS ONE · doi:10.1371/journal.pone.0221284 · Cited by 21 · see citing works
Osmani, F., Lago-Fuentes, C., Alemany-Iturriaga, J., & Barcala-Furelos, M. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1155037 · Cited by 6 · see citing works
“HR accuracy during physical exercise is important for monitoring and quantifying exercise intensity (Boudreaux et al., 2018).”
BackgroundMethod
- Authors
- BOUDREAUX, B. D., HEBERT, E. P., HOLLANDER, D. B., WILLIAMS, B. M., CORMIER, C. L., NAQUIN, M. R., GILLAN, W. W., GUSEW, E. E., & KRAEMER, R. R.
- Affiliations
- Southeastern Louisiana University (US)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2018-03
- Volume
- 50
- Issue
- 3
- Pages
- 624-633
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2770746328
- Cited by
- 205
- References
- 27
- Citations by year
- 2026: 11 · 2025: 29 · 2024: 20 · 2023: 35 · 2022: 27 · 2021: 23 · 2020: 19 · 2019: 30 · 2018: 11
- FWCI
- 12.14
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology › Physical Activity and Health
- Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- wearable activity trackers, heart rate monitoring, energy expenditure estimation, resistance training, device validity, exercise intensity, Apple Watch, Fitbit
- MeSH terms
- Fitness Trackers, Adult, Bicycling, Energy Metabolism, Exercise Test, Female, Heart Rate, Humans, Male, Monitoring, Physiologic, Resistance Training, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review